- Not Set - | Original | / | 3/11/2015 | | RITA | Location = - Not Set - by RITA | | - Not Set - | 767647 |
To Be Scanned Bin | Original | / | 3/11/2015 | | MINDY | Location = To Be Scanned Bin by MINDY | | To Be Scanned Bin | 767529 |
CO Springs Fire | Original | A | 2/11/2015 | CSFIRE | CSFIRE | Submitted By: Embres, Rhonda C
walk thru (see full review) | csfdit | CO Springs Fire | 761727 |
Out to Review | Original | / | 2/11/2015 | SHELLEY | SHELLEY | steve 492-6789 | | Out to Review | 761533 |
Construction | Original | A | 2/11/2015 | SHELLEY | SHELLEY | | | Construction | 761531 |
Mechanical | Original | A | 2/11/2015 | DALEH | DALEH | | | Mechanical | 761512 |
CO Springs DRE | Original | A | 2/9/2015 | LTHELEN | LTHELEN | ok to permit. Meets HS review criteria (see full review) | | CO Springs DRE | 760889 |
Finished Bin | Original | / | 1/12/2015 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 755943 |
CO Springs Fire | Original | D | 1/12/2015 | CSFIRE | CSFIRE | (see full review) | csfdit | CO Springs Fire | 755769 |
Fire | Original | / | 1/7/2015 | | LTHELEN | Location = Fire by LTHELEN | | Fire | 755221 |
CO Springs DRE | Original | D | 1/7/2015 | LTHELEN | LTHELEN | Make the following changes to the plan prior to approval: 1. On the site plan call out the TOW and BOW elevations for all retaining walls. 2. label the 5' and 7' public utility and drainage easements on the property. 3. Show and label the stockpile/equipment storage area. 4. Show all the utility line locations for all types of utilities. 5. Show any existing natural features or include a note that states " no natural features on the property." 6. Under project data include the lot coverage and % of driveway coverage in front yard setback. 7. On the elevations page show the building grade and the finished grade. Show a 35' height allowance from the building grade. Ensure all portions of the home are less than 35'. (see full review) | | CO Springs DRE | 755220 |
Zoning/Planning | Original | / | 12/31/2014 | | RITA | Location = Zoning/Planning by RITA | | Zoning/Planning | 754386 |
Plan Coordinator | Original | / | 12/31/2014 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 754356 |
Mechanical | Original | D | 12/31/2014 | RUSSELL | RUSSELL | Need O.A. duct for ventilation in Family Room in basement, under cut of toilet room door for R.A. path?, need loss shown for O.A. duct, see attached note on sheet A1.3 for location of appliances in the basement mech room, number of appliances in the mech room, and how obtaining combustion air for water heater(s) and makeup air for the dryer in the mech room? | | Mechanical | 754355 |
Mechanical | Original | / | 12/31/2014 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 754313 |
Mechanical | Original | / | 12/31/2014 | | RITA | Location = Mechanical by RITA | | Mechanical | 754305 |
Plan Coordinator | Original | / | 12/31/2014 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 754297 |
Construction | Original | D | 12/31/2014 | DANM | DANM | Clarify method of compliance on IECC Certificate Clarify truss labels K1 and location of K1A on main roof framing Clarify uplift connections on multiple girder trusses where truss design shows reactions greater than what an H2.5T will address See Plans Walk-through review OK | | Construction | 754296 |
Construction | Original | / | 12/31/2014 | DANM | DANM | In Current Review by DANM | | Construction | 754215 |
Construction | Original | / | 12/30/2014 | | RITA | Location = Construction by RITA | | Construction | 754172 |
Plan Coordinator | Original | / | 12/30/2014 | | SVETA | Location = Plan Coordinator by SVETA | | Plan Coordinator | 754149 |
Enumeration | Original | A | 12/30/2014 | SVETA | SVETA | per site plan | | Enumeration | 754148 |
Floodplain | Original | N | 12/29/2014 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 753804 |