Residential Certificate of Occupancy issued 10/26/2017




Permit Attachments: 4
DContractorIssuedStypeofconstattachnum  tid
B HOMEOWNER02/01/2021 A ?1BA1664411
E HOMEOWNER02/13/2021 A 2EA1668387
H HOMEOWNER02/23/2021 A 3HA1670266
P HOMEOWNER02/23/2021 A 4PA1670267


Inspection Requests: 0
View Required Inspections Click Here
ContractorCall Ahead #CommentCodeRequestedInspector# Image

EnteredNotes  
02/23/2021HOMEOWNER 2/13/2021 Electrical attachment transferred from N33317 by RITA on 2/23/2021RITA303863

Inspection History: 8
ContractorCodeSDateInspector CommentsInspectorInspectorusername   
HOMEOWNER BFR P 02/24/2021Frame OK pending completion of outstanding rough inspections JASONL JASONLBFR P6879482
HOMEOWNER BFR R 02/22/2021Need to attach mechanical permit and complete inspections / Need to attach electrical and plumbing permits for new work installed and complete inspections / Missing fire blocking throughout / Reviewed Smoke and CO requirements / JASONL JASONLBFR R6876673
HOMEOWNER ER C 02/22/2021ER OK ---- 1/0 TO SUB PANEL ----- CHECK ELEC. FIRE PLACE AT FINAL ---- GREGM GREGMER C6878069
HOMEOWNER HRR C 03/01/2021 LIDO LIDOHRR C6883545
HOMEOWNER HRR P 02/24/2021DRYER EXHAUST DUCT MUST BE INSTALLED / HOMEOWNER WILL SET BATH EXHAUST FAN WITH 4 INCH EXHAUST DUCT TO 50 CFM / BY FINAL SEAL OUTSIDE TERMINATIONS TO BOTH NEW BATH EXHAUST DUCTS / BY FINAL PROVIDE NECESSARY COMBUSTION AIR FOR WATER HEATER IN MECHANICAL ROOM / NOTE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / THERMOSTAT FAN WILL OPERATE AS MECHANICAL VENTILATION IN NEW FINISHED BASEMENT REC ROOM / DIRECT VENT FURNACE ANGELW ANGELWHRR P6879591
HOMEOWNER PB C 03/01/2021 W-BOX UNDERGROUND OK LEE LEEPB C6883769
HOMEOWNER PTO P 02/24/2021 USE CODE APPROVED TUB / SHOWER ADAPTORS ON VALVE -- NEED TUB SPOUT TO BE RIDGID PIPE -- SUPPORT PEX IN CEILING ABOVE BAR SINK -- MAY NEED MIXING VALVE AT SOAKER TUB -- INSTALL AND ANCHOR CLOSET FLANGES -- NEED LISTING ON JETTED SOAKER TUB LEE LEEPTO P6879962
HOMEOWNER PB P 02/24/2021 REVISE FIXTURE SCOPE TO INCLUDE BOTH BATHROOMS, BAR AND W-BOX -- NEED TEST ON NEW W-BOX DWV UNDERGROUND -- OTHER BATH OK TO COVER PENDING TUB APPROVAL (3RD PARTY LISTING ?) LEE LEEPB P6879938