RICHMOND AMERICAN HOMES OF COLORADO, INC. | B= | C | 01/18/2023 | | JASONL | JASONL | | B= | C | 7637457 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BIN | C | 01/03/2023 | 3rd Party Insulation Certificate on file / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | JASONL | JASONL | | BIN | C | 7623563 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | B= | P | 12/29/2022 | Temp CO: Pending finals ( Expires: 01/28/2023) | WEBSITE | WEBSITE | | B= | P | 7622617 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | B= | P | 12/29/2022 | Building final OK pending completion of BIN inspection and N= (engineering) / Crawspace / No decks. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DOUGC | DOUGC | | B= | P | 7622610 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | B= | T | 12/29/2022 | PAID (REC#1923402): AFTER-HOURS INSPECTION: $200 From: DAKOTAB After Hours B= | DAKOTAB | DAKOTAB | | B= | T | 7622156 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BSP | P | 12/14/2022 | Observed front porch posts and post connections | JASONL | JASONL | | BSP | P | 7610740 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BSP | R | 12/12/2022 | Porch post inspection / Porch posts cap hardware does not meet the requirements for any condition 1-4 on 601 SD / | JASONL | JASONL | | BSP | R | 7607910 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFR | C | 11/03/2022 | Front porch lid still missing post, okay to check under a BSP inspection. | ERAMIREZ | ERAMIREZ | | BFR | C | 7572175 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFR | P | 11/01/2022 | Missing (2) kings each side of garage service door / Missing header to trimmer straps at garage overhead door per detail 604 on SD / Need to strap walls together at double plate break at steel beam in garage each end / Missing hanger on all joists at LVL rim above sliding glass door / Missing point load above sliding glass door / Missing (2) 2x4 header above pantry door / Need to roll block and missing 2x post under LVL east side of stairs main level / Missing bracing at post in crawlspace per detail 396 on SD / Missing post to foundation in crawlspace under (7) 2x post under steel beam south side garage / Missing posts at front porch / Observed rest of front porch lid framing | JASONL | JASONL | | BFR | P | 7569015 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BIN | P | 10/31/2022 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 7567381 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFD | C | 10/31/2022 | Damp proofing observation on file | DOUGC | DOUGC | | BFD | C | 7566996 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BSP | R | 10/28/2022 | Foundation drain observation already on file. / Damp proofing not noted on drain observation | MATTHEWA | MATTHEWA | | BSP | R | 7565583 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFD | P | 10/28/2022 | Damp proofing not noted on foundation drain observation. / Engineer letter for perimeter drain on file. / Sump pit | MATTHEWA | MATTHEWA | | BFD | P | 7565577 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFN | C | 10/28/2022 | open hole on file -- 3,000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | MATTHEWA | MATTHEWA | | BFN | C | 7565573 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFT | C | 10/28/2022 | open hole on file -- 3,000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | MATTHEWA | MATTHEWA | | BFT | C | 7565572 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BSP | T | 08/03/2022 | PAID (REC#1888763): Shear walls previously inspected / Need to complete foundation inspections | GREGT | GREGT | | BSP | T | 7470298 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BSP | P | 07/29/2022 | observed exterior shear / need to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 7464843 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFD | P | 05/05/2022 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFD | P | 7365506 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFT | P | 05/05/2022 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 7365505 |
RICHMOND AMERICAN HOMES OF COLORADO, INC. | BFN | P | 05/05/2022 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 7365504 |
DELMARK ELECTRIC INC | E= | C | 12/15/2022 | E= OK ----- 20 AMP A/C ------ | GREGM | GREGM | | E= | C | 7612171 |
DELMARK ELECTRIC INC | ES | C | 10/12/2022 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | GREGM | GREGM | | ES | C | 7548458 |
DELMARK ELECTRIC INC | ER | C | 10/12/2022 | ER OK --- #8AL RANGE DRYER A/C --- REVERSIBLE UFER --- NO MCC ---14/2 FRIDGE --- | GREGM | GREGM | | ER | C | 7548455 |
TOM JOHNSON, INC. | H= | C | 12/21/2022 | WHOLE HOUSE VENTILATION SWITCH DOES NOT CONTROL THE FAN. SUPPORT FURNACE VENTING IN MECHANICAL ROOM. WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / WHOLE HOUSE VENTILATION SWITCH LOCATED IN MECHANICAL ROOM / NOTE / CONDITIONED CRAWL SPACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / HIGH/LOW GRILLES INTO WATER HEATER MECHANICAL ROOM / DIRECT VENT FURNACE / A/C COMPLETE / | JONH | JONH | | H= | C | 7617836 |
TOM JOHNSON, INC. | H= | P | 12/20/2022 | ( WATER HEATER AND VENTING WILL BE VERIFIED BY PLUMBING INSPECTOR. NO POWER/SWITCH TO CRAWL SPACE FAN. DUCT DESIGN SHOW TWO 6X10 EXHAUST LOCATIONS IN CRAWL SPACE ONLY ONE INSTALLED. WHOLE HOUSE VENTILATION SWITCH DOES NOT CONTROL THE FAN. SUPPORT FURNACE VENTING IN MECHANICAL ROOM. WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / WHOLE HOUSE VENTILATION SWITCH LOCATED IN MECHANICAL ROOM / NOTE / CONDITIONED CRAWL SPACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / HIGH/LOW GRILLES INTO WATER HEATER MECHANICAL ROOM / DIRECT VENT FURNACE / A/C COMPLETE / | ROBERTC | ROBERTC | | H= | P | 7616692 |
TOM JOHNSON, INC. | H= | P | 12/20/2022 | DUCT LEAKAGE REPORT RECEIVED, SEE IMAGES / | JONH | JONH | | H= | P | 7615595 |
TOM JOHNSON, INC. | H= | P | 12/06/2022 | NOT READY. PROVIDE DUCT LEAKAGE REPORT. WHOLE HOUSE VENTILATION SWITCH IN MECHANICAL ROOM IS NOT CONTROLLING THE FAN. NO POWER THROUGHOUT THE HOUSE. WATER HEATER MISSING CONDENSATE DRAIN. CAP/COMPLETE KITCHEN EXHAUST. FAN/DUCT IN CRAWL SPACE IS INCOMPLETE. INSPECTION STOPPED RE-INSPECT ALL. | ROBERTC | ROBERTC | | H= | P | 7602120 |
SPRINGS GAS, INC. | HC | C | 10/26/2022 | RELEASE METER | JONH | JONH | | HC | C | 7563130 |
SPRINGS GAS, INC. | HI | C | 10/26/2022 | 10 LB TEST OK / 1 INCH MAIN / 1 FURNACE / 1 RANGE / 1 WATER HEATER / | JONH | JONH | | HI | C | 7563118 |
TOM JOHNSON, INC. | HRR | C | 10/12/2022 | BY FINAL PROVIDE DUCT LEAKAGE REPORT. LABEL OUTSIDE AIR DAMPER IN MECHANICAL ROOM. COMPLETE DUCT/FAN IN CRAWL SPACE. WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / CONDITIONED CRAWL SPACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / A/C ROUGH, COIL AND LINESET / | ROBERTC | ROBERTC | | HRR | C | 7548457 |
CONFIDENCE PLUMBING CO., INC | P= | C | 12/29/2022 | Note : PVB installed | FRANKM | FRANKM | | P= | C | 7622102 |
CONFIDENCE PLUMBING CO., INC | P= | R | 12/28/2022 | no water, re- inspect all. | TAYLOR | TAYLOR | | P= | R | 7620946 |
CONFIDENCE PLUMBING CO., INC | PTO | C | 10/20/2022 | Corrections complete | FRANKM | FRANKM | | PTO | C | 7557253 |
CONFIDENCE PLUMBING CO., INC | PTO | P | 10/07/2022 | Water heater exhaust touching combustibles / sch. 40 piping required to 30'' outside building (inspection required) , rest ok | FRANKM | FRANKM | | PTO | P | 7543354 |
CONFIDENCE PLUMBING CO., INC | PTO | P | 10/06/2022 | Connect water heater exhaust Note : water heater vent & test ok / crawlspace / irrigation stub / 4 - VTR / chk. wtr. htr. exhaust termination @ final | FRANKM | FRANKM | | PTO | P | 7541772 |
CONFIDENCE PLUMBING CO., INC | PSP | P | 10/06/2022 | Water Heater Plastic Vent by Plumbing Contractor | SYSTEM | SYSTEM | | PSP | P | 7541371 |