COLORADO STRUCTURES INC | B= | C | 09/18/2006 | OK PER DALE FOR CO. ALL OTHERS SIGNED OFF | MINDY | MINDY | | B= | C | 3234718 |
COLORADO STRUCTURES INC | B= | P | 09/12/2006 | NEED ALL DEPARTMENTS SIGNED OFF, FIRE AND ZONING | DALE | DALE | | B= | P | 3234706 |
COLORADO STRUCTURES INC | B= | P | 09/12/2006 | FULL TCO ISSUED FOR CUSTOMER USE EXPIRES OCTOBER 12 2006 | JAN | JAN | | B= | P | 3234698 |
COLORADO STRUCTURES INC | BSP | P | 08/25/2006 | EXIT LIGHTING OK --- DBL CHECK EXIT LIGHTING AT FINAL | JIMA | JIMA | | BSP | P | 3234568 |
COLORADO STRUCTURES INC | B= | P | 08/04/2006 | LIMITED TO WAL-MART EMPLOYEES AND JOB APPLICANTS / NO GENERAL PUBLIC / APPLICANTS TO BE PROTECTED / ISSOLATED FROM STORE SET-UP OPPERATIONS | MICHAELA | MICHAELA | | B= | P | 3234693 |
COLORADO STRUCTURES INC | BSP | R | 07/20/2006 | FIREWALL NOT COMPLETELY SEALED | MICHAELA | MICHAELA | | BSP | R | 3234686 |
COLORADO STRUCTURES INC | BFR | C | 07/11/2006 | | MICHAELA | MICHAELA | | BFR | C | 3234680 |
COLORADO STRUCTURES INC | BIN | C | 07/11/2006 | | MICHAELA | MICHAELA | | BIN | C | 3234674 |
COLORADO STRUCTURES INC | BFR | P | 07/07/2006 | FRAMING AT GARDEN CTR. AND FIRE WALL OK TO COVER - SEE PLAN FOR VERIFICATION | MICHAELA | MICHAELA | | BFR | P | 3234667 |
COLORADO STRUCTURES INC | BFR | P | 06/28/2006 | NORTH EAST ELEC. / SOUTH EAST ENTRY - SEE PLAN FOR PRECISE LOCATION | MICHAELA | MICHAELA | | BFR | P | 3234660 |
COLORADO STRUCTURES INC | BIN | P | 06/28/2006 | SOUTH WEST CORNER - SEE PLAN FOR PRECISE LOCATION | MICHAELA | MICHAELA | | BIN | P | 3234655 |
COLORADO STRUCTURES INC | BFR | P | 06/20/2006 | SOUTH AND WEST PERIMETER STEEL STUD WALLS AND BULKHEADS OK TO COVER - SEE APPROVED PLAN FOR SPECIFIC AREAS | MICHAELA | MICHAELA | | BFR | P | 3234648 |
COLORADO STRUCTURES INC | BFR | P | 06/09/2006 | INTERIOR FRAMING OK TO OVER AS INDICATED ON RBD SET IN TRAILER | MICHAELA | MICHAELA | | BFR | P | 3234640 |
COLORADO STRUCTURES INC | BFR | R | 06/07/2006 | NO ONE AT JOB TRAILER - CAN'T FIND ANYONE ON SITE - PLEASE PROVIDE CONTACT PHONE NUMBER FOR FUTURE INSPECTIONS | MICHAELA | MICHAELA | | BFR | R | 3234633 |
COLORADO STRUCTURES INC | BFR | P | 05/11/2006 | ROOF/CEILING ASSEMBLIES EXT. CART STORAGE E. AND W. END - SEE PERMIT SET | MICHAELA | MICHAELA | | BFR | P | 3234624 |
COLORADO STRUCTURES INC | BFR | P | 04/21/2006 | FRONT GABLES OVER ENTRY - SEE PLAN FOR SPEC. LOCATION | MICHAELA | MICHAELA | | BFR | P | 3234616 |
COLORADO STRUCTURES INC | BFR | P | 04/12/2006 | EXTERIOR METAL STUDS ON CMU - OK TO COVER -SEE APPRV. PLAN FOR SPECIFIC LOCATIONS | MICHAELA | MICHAELA | | BFR | P | 3234609 |
COLORADO STRUCTURES INC | BFN | P | 03/20/2006 | OK FOR ENGINEER TO INSPECT | DAVEL | DAVEL | | BFN | P | 3234600 |
COLORADO STRUCTURES INC | BBB | P | 03/16/2006 | ENGINEER OF RECORD - PER BEV P | JEREMY | JEREMY | | BBB | P | 3234576 |
COLORADO STRUCTURES INC | BFN | P | 03/16/2006 | ENGINEER OF RECORD - PER BEV P | JEREMY | JEREMY | | BFN | P | 3234584 |
COLORADO STRUCTURES INC | BFT | P | 03/16/2006 | ENGINEER OF RECORD - PER BEV P | JEREMY | JEREMY | | BFT | P | 3234592 |
BIBLE ELECTRIC, INC. | ER | C | 09/13/2006 | SUBWAY ELECTRICAL ROUGH AND FINAL INSPECTIONS DONE FOR BIBLE ELEC, UNDER WALMART PERMIT, NOT SUBWAY G02843. | DEAN | DEAN | | ER | C | 3235381 |
BIBLE ELECTRIC, INC. | E= | C | 09/13/2006 | SUBWAY INSIDE WALMART ELECTRICAL ROUGH AND FINAL COMPLETED UNDER WALMART PERMIT, NOT PERMIT #02843. | DEAN | DEAN | | E= | C | 3235374 |
BIBLE ELECTRIC, INC. | E= | P | 09/12/2006 | CONTRACTOR HAS CORRECTION LIST, STILL HAVE FRONT OF STORE VESTIBULE TO VESTIBULE TO INSPECT. | DEAN | DEAN | | E= | P | 3235366 |
MOUNTAIN BROTHERS ELECTRIC CO. | E= | C | 09/11/2006 | | DEAN | DEAN | | E= | C | 3235411 |
MOUNTAIN BROTHERS ELECTRIC CO. | E= | R | 09/08/2006 | NO ONE ON SITE TO OPEN UP SOME EQUIPMENT TO CHECK CONNECTIONS. | DEAN | DEAN | | E= | R | 3235404 |
BIBLE ELECTRIC, INC. | E= | P | 08/11/2006 | DELI CEILING OK, PARKING LOT LIGHTS OK. | DEAN | DEAN | | E= | P | 3235358 |
BIBLE ELECTRIC, INC. | E= | P | 08/03/2006 | OK TO OCCUPY, STILL HAVE CORRECTIONS AND COMPLETION OF WORK AS DISCUSSED WITH CONTRACTOR. | DEAN | DEAN | | E= | P | 3235350 |
BIBLE ELECTRIC, INC. | ER | P | 08/02/2006 | ALL CEILINGS OK EXCEPT DELI DEPARTMENT. | DEAN | DEAN | | ER | P | 3235342 |
BIBLE ELECTRIC, INC. | EP | P | 08/01/2006 | PNLS LTS1 &2, LHC, LRX OK, ALL RTU'S OK, STILL NEED TO SEE EXHAUST FANS ON ROOF. | DEAN | DEAN | | EP | P | 3235335 |
BIBLE ELECTRIC, INC. | ER | P | 08/01/2006 | ABOVE CEILING IN PHARMACY OK. | DEAN | DEAN | | ER | P | 3235328 |
BIBLE ELECTRIC, INC. | ES | C | 07/28/2006 | COMMERCIAL SERVICE: 4000-AMP 480-VOLT NEW SERVICE BY BIBLE ELEC. | DEAN | DEAN | | ES | C | 3235321 |
BIBLE ELECTRIC, INC. | ER | P | 07/27/2006 | PARTIAL FOR RTU'S, NEED TO SEE WIRING COMPARTMENT ON ALL UNITS. | DEAN | DEAN | | ER | P | 3235314 |
BIBLE ELECTRIC, INC. | ER | R | 07/25/2006 | REMOVE 25% OF TILES IN FRONT LAY IN CIELINGS | THOMAS | THOMAS | | ER | R | 3235306 |
BIBLE ELECTRIC, INC. | ER | P | 07/24/2006 | RECHECK ABOVE CEILING SUPPORTS | GARY | GARY | | ER | P | 3235298 |
BIBLE ELECTRIC, INC. | ER | P | 07/20/2006 | CEILING AREAS AS MARKED ON SHEET E1.1 | DEAN | DEAN | | ER | P | 3235290 |
BIBLE ELECTRIC, INC. | ER | P | 07/17/2006 | ABOVE HARD LID IN EAST VESTIBULE AS MARKED ON SHEET E1 AND E1.1 | DEAN | DEAN | | ER | P | 3235282 |
BIBLE ELECTRIC, INC. | ER | P | 07/14/2006 | ABOVE HARD LID IN GROCERY VESTIBULE OK AS MARKED ON SHEETS E1 AND E1.1 | DEAN | DEAN | | ER | P | 3235275 |
BIBLE ELECTRIC, INC. | ER | P | 07/12/2006 | WALLS IN PHARMACY PER SHEETS E 2.1 AND E2.3, STILL NEED TO SEE COUNTER . | DEAN | DEAN | | ER | P | 3235267 |
BIBLE ELECTRIC, INC. | ER | P | 07/10/2006 | WALLS CUSTOMER SERVICE AND SUBWAY OK EXCEPT COUNTERS THAT ARE NOT INSTALLED YET. MARKED ON PRINT E2.1. | DEAN | DEAN | | ER | P | 3235261 |
BIBLE ELECTRIC, INC. | ER | P | 07/07/2006 | WALLS AND HARD LID AS MARKED ON PRINTS SHEET E 2. | DEAN | DEAN | | ER | P | 3235232 |
BIBLE ELECTRIC, INC. | ER | P | 07/05/2006 | WALLS AND HARD LID MARKED ON SHEET E2.1. | DEAN | DEAN | | ER | P | 3235224 |
BIBLE ELECTRIC, INC. | ER | P | 06/26/2006 | WALLS TENANT SPACE E2.2, AND WALLS FOR OFFICE E1.1. | DEAN | DEAN | | ER | P | 3235216 |
BIBLE ELECTRIC, INC. | ER | P | 06/22/2006 | WALLS GROCERY AREA MARKED ON PRINT E2.1 | DEAN | DEAN | | ER | P | 3235212 |
BIBLE ELECTRIC, INC. | ER | P | 06/15/2006 | WALLS COL. 12 -PAST 8. J-H | MIKEC | MIKEC | | ER | P | 3235205 |
BIBLE ELECTRIC, INC. | ER | P | 06/13/2006 | WALLS TRAINING RM, BREAK RM, AND SMOKE RM MARKED ON PRINTS. | DEAN | DEAN | | ER | P | 3235197 |
BIBLE ELECTRIC, INC. | ER | P | 06/09/2006 | BATHROOMS | MIKEC | MIKEC | | ER | P | 3235189 |
BIBLE ELECTRIC, INC. | EUG | P | 05/03/2006 | COMPLETION OF SECONDARY FROM BUILDING OUT TO XFMR LOCATION OK. | DEAN | DEAN | | EUG | P | 3235182 |
BIBLE ELECTRIC, INC. | EUG | P | 05/02/2006 | UNDER SLAB CONDUITS FOR REFRIDGERATION IN GROCERY OK. | DEAN | DEAN | | EUG | P | 3235175 |
BIBLE ELECTRIC, INC. | EUG | P | 04/11/2006 | SITE LTNG ALONG SOUTH ROAD OK. | DEAN | DEAN | | EUG | P | 3235167 |
BIBLE ELECTRIC, INC. | EUG | P | 03/15/2006 | COMPLETION OF PNL FEEDERS UNDER SLAB OK. | DEAN | DEAN | | EUG | P | 3235159 |
BIBLE ELECTRIC, INC. | EUG | P | 03/10/2006 | PARTIAL UNDER SLAB PNL FEEDERS. | DEAN | DEAN | | EUG | P | 3235149 |
BIBLE ELECTRIC, INC. | EUG | P | 03/03/2006 | | MIKEC | MIKEC | | EUG | P | 3235141 |
BIBLE ELECTRIC, INC. | EUG | P | 03/01/2006 | AREA OF SITE LTNG MARKED ON PLANS. | DEAN | DEAN | | EUG | P | 3235133 |
BIBLE ELECTRIC, INC. | EUG | P | 02/28/2006 | UFER OK. | DEAN | DEAN | | EUG | P | 3235126 |
BIBLE ELECTRIC, INC. | EUG | P | 02/21/2006 | AREA OF SITE LTNG MARKED ON PRINT. | DEAN | DEAN | | EUG | P | 3235118 |
BIBLE ELECTRIC, INC. | EUG | P | 02/14/2006 | SECONDARY CONDUITS FROM BLDG OUT APPROX 50FT OK. | DEAN | DEAN | | EUG | P | 3235110 |
INTERSTATE MECHANICAL, INC. | H= | C | 09/19/2006 | GAS FINAL. | LYNNS | LYNNS | | H= | C | 3234855 |
FRONTIER MECHANICAL INC. | H= | C | 09/13/2006 | RECEIVED BALANCE REPORT ON 9/13/06 FROM PRECISIONAIRE OF TEXAS, HOUSTON, TX. | LYNNS | LYNNS | | H= | C | 3234819 |
KOOOL TOUCH | H= | C | 09/13/2006 | HRP FINAL. | LYNNS | LYNNS | | H= | C | 3235396 |
FRONTIER MECHANICAL INC. | H= | P | 08/28/2006 | HVAC FINAL PENDING RECEIPT OF BALANCE REPORT. | LYNNS | LYNNS | | H= | P | 3234812 |
INTERSTATE MECHANICAL, INC. | H= | P | 08/11/2006 | 6- 10# TESTS ON LINES TO UNIT HEATER OK. NEED TO LABEL MEDIUM PRESSURE LINES, TAG ALL REGULATORS, VENT INSIDE REGULATORS TO OUTSIDE. | LYNNS | LYNNS | | H= | P | 3234848 |
INTERSTATE MECHANICAL, INC. | HC | C | 08/03/2006 | OK FOR METER, ELEVATED PRESSURE. | LYNNS | LYNNS | | HC | C | 3234841 |
INTERSTATE MECHANICAL, INC. | HI | C | 08/03/2006 | UNIONS REMOVED. | LYNNS | LYNNS | | HI | C | 3234833 |
KOOOL TOUCH | HRP | C | 08/02/2006 | REF. LINES AND TEST LOG RESULTS OK. | LYNNS | LYNNS | | HRP | C | 3235389 |
FRONTIER MECHANICAL INC. | H= | P | 07/28/2006 | OFFICE AREA OK FOR TILE. | LYNNS | LYNNS | | H= | P | 3234805 |
FRONTIER MECHANICAL INC. | HV | P | 07/26/2006 | 5- UNIT HEATER VENTS, NEED TO RAISE B-VENT ABOVE PARAPET WALL WITH IN 8'. BAY EXHAUST OK. | LYNNS | LYNNS | | HV | P | 3234796 |
FRONTIER MECHANICAL INC. | H= | P | 07/25/2006 | PARTIAL FINAL IN REAR OFFICES OK. | LYNNS | LYNNS | | H= | P | 3234788 |
INTERSTATE MECHANICAL, INC. | HI | P | 07/24/2006 | 60# TEST AND DESIGN OK. NEED TO REMOVE UNIONS AND REPLACE AS DISCUSSED WITH CONTRACTOR. | LYNNS | LYNNS | | HI | P | 3234826 |
FRONTIER MECHANICAL INC. | HD | P | 07/17/2006 | VESTABULES AND CART STORAGE ROUGH DUCT OK TO INSULATE. | LYNNS | LYNNS | | HD | P | 3234781 |
FRONTIER MECHANICAL INC. | HD | P | 07/07/2006 | ROUGH DUCT ON RTU'S 8, 12, 14 AND 15. BATH EXHAUST IN FRONT BATHS AND AUTO CENTER OK, BANK OFFICES ROUGH ABOVE CEILING OK. | LYNNS | LYNNS | | HD | P | 3234773 |
FRONTIER MECHANICAL INC. | HD | P | 06/08/2006 | ROUGH DUCT ON RTU'S 3, 6, 7, 9, 10, 11, 30, 31, 32 33, 34 AND 35. JOBSITE CONTACT: DJ 720-939-9589. | LYNNS | LYNNS | | HD | P | 3234765 |
INTERSTATE MECHANICAL, INC. | P= | C | 09/13/2006 | STORE COMPLETE | DOUGR | DOUGR | | P= | C | 3235102 |
INTERSTATE MECHANICAL, INC. | P= | P | 08/22/2006 | SEAFOOD AREA HAS FOOT OPERATED HAND SINK, WITH BACKGRADE. 3- COMPARTMENT SINK NEEDS TO HAVE DRAIN DIRECTED INTO FLOOR SINK, WITH NO SPLASHING ONTO FLOOR. BAKERY 3- COMPARTMENT SINK HAS BACKGRADE ON LEFT SIDE. PREP SINK NEEDS DRAIN DIRECTED INTO FLOOR SINK. 2'' VENT THROUGH FLOOR, AND 1/2'' LINE NEED TO BE SLEEVED THROUGH FLOOR. DELI FOOT CONTROLLED SINK NEEDS 1'' AIR-GAP TO HUB DRAIN. NO HOT WATER THROUGHOUT. | SCOTT | SCOTT | | P= | P | 3235094 |
INTERSTATE MECHANICAL, INC. | PRD | P | 08/22/2006 | 1-12'' OVERFLOW DRAIN ABOVE COMPUTER ROOM IS OK. 2ND. ONE DRAIN TO REPAIR LEAK. | SCOTT | SCOTT | | PRD | P | 3235086 |
INTERSTATE MECHANICAL, INC. | PRD | P | 08/15/2006 | LACKS TWO OVERFLOW DRAINS ON WEST END AND ALL TRANSITION BANDS | LEE | LEE | | PRD | P | 3235078 |
INTERSTATE MECHANICAL, INC. | PRD | P | 08/11/2006 | LACKS 3- CENTER OVERFLOWS, 2- PRIMARYS (LEAKS FROM PREVIOUS INSPECTION) AND ALL TRANSITION BANDS | LEE | LEE | | PRD | P | 3235070 |
INTERSTATE MECHANICAL, INC. | PRD | P | 08/09/2006 | END THREE OVERFLOW DRAINS WEST END OK, NOTE: STILL NEED APPROVED TRANSITION BANDS ON ALL DRAINS | LEE | LEE | | PRD | P | 3235063 |
INTERSTATE MECHANICAL, INC. | PRD | P | 08/08/2006 | ONE PRIMARY OUT OF THE LAST THREE ON WEST END OK, LEAKS ON OTHER TWO, PROVIDE ACCESS ATOP COOLERS FOR INSPECTION OF LAST TWO PRIMARYS | LEE | LEE | | PRD | P | 3235054 |
INTERSTATE MECHANICAL, INC. | PRD | P | 08/04/2006 | ALL PRIMARYS MINUS THREE ON WEST SIDE OK | LEE | LEE | | PRD | P | 3235046 |
INTERSTATE MECHANICAL, INC. | PRD | P | 08/01/2006 | EAST THREE PRIMARY DRAINS ONLY PENDING TRANSITION BANDS CHANGED OUT | LEE | LEE | | PRD | P | 3235038 |
INTERSTATE MECHANICAL, INC. | P= | P | 08/01/2006 | REAR PUBLIC RESTROOMS MINUS DRINKING FOUNTAINS | LEE | LEE | | P= | P | 3235030 |
INTERSTATE MECHANICAL, INC. | PRD | P | 07/31/2006 | EAST THREE SET OF PRIMARY DRAINS ONLY, INSULATION HAS WET SPOTS IN SEVERAL AREAS, REMOVE INSULATION FOR RE-INSPECTION | LEE | LEE | | PRD | P | 3235022 |
INTERSTATE MECHANICAL, INC. | PRD | R | 07/28/2006 | PIPE ALL INSULATED, USE PROPER TRANSITION BANDS AT DRAIN BODIES TO PVC, LOW TEST ON ALL AND NO TEST ON SECONDARYS (EAST 3- SETS ONLY) | LEE | LEE | | PRD | R | 3235012 |
INTERSTATE MECHANICAL, INC. | PTO | P | 07/13/2006 | PHARMACY & TLE | LARRY | LARRY | | PTO | P | 3235004 |
INTERSTATE MECHANICAL, INC. | PTO | P | 07/13/2006 | PHARMACY AND TLE AREA OK | LARRY | LARRY | | PTO | P | 3234996 |
INTERSTATE MECHANICAL, INC. | PTO | P | 07/10/2006 | SUBWAY, HAIR SALON, EYECARE OK. PHARMACY PENDING | LARRY | LARRY | | PTO | P | 3234988 |
INTERSTATE MECHANICAL, INC. | PTO | P | 07/07/2006 | HAIR SOLON RETEST ABOVE WALLS, VISION AREA OK | JACK | JACK | | PTO | P | 3234980 |
INTERSTATE MECHANICAL, INC. | PTO | P | 06/27/2006 | FRONT BATH GROUP, DELI, BAKERY, ALL WEST SIDE GROCERY AREA - WASTE, VENTS, & WATER PIPE COMPLETE | DOUGR | DOUGR | | PTO | P | 3234972 |
INTERSTATE MECHANICAL, INC. | PTO | T | 06/26/2006 | PAID (REC#703803)NOT READY---STATE ON REQUEST WHAT YOU WANT AND WHERE IT IS---GROCERY AREA WAS TO BE INSPECTED--1) NO SUPPORTS ON DWV 2) SOME SINKS WERE NOT SSTUBBED OUT OF WALLS 3) ONE SINK THRU SLAB HAS COME APART UNDER THE FLOOR AND WAS NOT STUBBED OUT 4) MISC COPPER LINES ARE NOT SUPORTED IN WALLS ( ISOLATED TOO FROM GALV STUDS) | LYNNIE | LYNNIE | | PTO | T | 3234964 |
INTERSTATE MECHANICAL, INC. | PTO | P | 06/14/2006 | REAR MAIN RESTROOMS, FAMILLY BATHROOM, BREAK SINK AND REAR JANITORS CLOSET DWV AND H20 OK | LEE | LEE | | PTO | P | 3234956 |
INTERSTATE MECHANICAL, INC. | PB | C | 04/17/2006 | | LEE | LEE | | PB | C | 3234950 |
INTERSTATE MECHANICAL, INC. | PB | P | 04/12/2006 | H20 ENTRY AND JANITORS CLOSET SAME AREA OK | LEE | LEE | | PB | P | 3234942 |
INTERSTATE MECHANICAL, INC. | PRD | P | 04/12/2006 | UNDERGROUND COMPLETE | LEE | LEE | | PRD | P | 3234934 |
INTERSTATE MECHANICAL, INC. | PRD | P | 04/11/2006 | TWO 12" DRAINS UNDERGROUND AT LOADING DOCK AND THREE 12" DRAINS EAST END OK | LEE | LEE | | PRD | P | 3234926 |
INTERSTATE MECHANICAL, INC. | PB | P | 04/11/2006 | LOADING DOCK DWV, NEED TO COMPLETE WEST END AND REPAIR LEAKS NEAR TERMINATION ON 4" WYE, REAR PUBLIC RESTROOMS OK, FAMILY RESTROOM OK | LEE | LEE | | PB | P | 3234919 |
INTERSTATE MECHANICAL, INC. | PRD | P | 04/06/2006 | NEED TO UNCOVER ALL FITTINGS ON 12" UNDERGROUND EAST SIDE, LOW TEST, WEST 12" UNDERGROUND DRAIN LACKS TEST | LEE | LEE | | PRD | P | 3234912 |
INTERSTATE MECHANICAL, INC. | PB | P | 04/06/2006 | C.W.V. AND GREASE WASTE COMPLETE FROM COLUMN E TO J & 1 TO 4 | LEE | LEE | | PB | P | 3234905 |
INTERSTATE MECHANICAL, INC. | PB | P | 03/24/2006 | RECHECKED TEST ALL GOOD FOR LEE'S NOTES FROM PREVIOUS INSPECTION, FITTINGS CHANGED TO 45'S | JACK | JACK | | PB | P | 3234899 |
INTERSTATE MECHANICAL, INC. | PB | P | 03/23/2006 | CWV, LOW TEST, NO 90S ALLOWED AT HORIZ TO VERTICAL, NEED 3" VENT AT UPPER END OF CWV NEAR COLUMN 3, GREASE WASTE HAD LOW TEST, LACKS FULL SIZE C/OUTS ON FOUR BRANCHES, TRENCH DRAIN NOT COMPLETE, INSPECTED FROM UPPER END TO COLUMN "D" ON BOTH SANITARY AND GREASE, TOLD PLUMBER TO HAVE TEST UP TO TOP OF PIPE OR WILL NOT PASS (GROUND TO WET TO CONFIRM LEAKS) CAN COVER AREAS NOT AFFECTED AT OWN RISK | LEE | LEE | | PB | P | 3234893 |
INTERSTATE MECHANICAL, INC. | PB | P | 03/10/2006 | APPROVED PLANS LOCKED UP, LOOKED AT SANITARY UP FRONT GRID 4 THRU 10, PROCEED AT OWN RISK | LEE | LEE | | PB | P | 3234887 |
INTERSTATE MECHANICAL, INC. | PB | P | 03/09/2006 | SANITARY UP FRONT, THREE FLOOR DRAINS MISSING P-TRAPS AND VENTS ?, NEED FULL SIZE EOL C/O AT VISION CENTER, REPLACE 1/4 BEND ON F/D IN PHARMACY | LEE | LEE | | PB | P | 3234879 |
INTERSTATE MECHANICAL, INC. | PB | P | 02/28/2006 | GARDEN CENTER TRUNK COMPLETE, PHOTO LAB TRUNK, TRAP AND STACK COMPLETE, FISH TANK TRUNK AND TRAP COMPLETE | LEE | LEE | | PB | P | 3234874 |
INTERSTATE MECHANICAL, INC. | PB | P | 02/15/2006 | TRUNK LINES ONLY AT REAR RESTROOMS, LOADING DOCK AND TIRE & LUBE N/E CORNER | LEE | LEE | | PB | P | 3234869 |
INTERSTATE MECHANICAL, INC. | PB | P | 02/03/2006 | SANITARY TRUNK AND RISERS ONLY NORTH TO SOUTH, COLUMNS (B TO H) BETWEEN (10 AND 11) | LEE | LEE | | PB | P | 3234862 |