TANDEM ENTERPRISES INC | B= | C | 10/09/2007 | PER DELLA IN PALMER LAKE OKAY TO ISSUE CO ON THIS ADDRESS. 10-10-07 | ANGELA | ANGELA | | B= | C | 3387679 |
TANDEM ENTERPRISES INC | B= | P | 05/07/2007 | NEED PALMER LAKE APPROVAL | JOND | JOND | | B= | P | 3387671 |
TANDEM ENTERPRISES INC | B= | P | 05/04/2007 | 2 SOUTH CLOSET SHAFTS NOT SEALED PROPERLY / PALMER LAKE SIGN OFF | JOND | JOND | | B= | P | 3387663 |
TANDEM ENTERPRISES INC | B= | R | 05/03/2007 | CANCELLED IN FIELD | JOND | JOND | | B= | R | 3387654 |
TANDEM ENTERPRISES INC | B= | P | 04/15/2007 | TEMP CO: STILL NEED M=, Z=, AND B=//TCO EXTENDED UNTIL 5/15/07 TO ALLOW FOR CONSTRUCTION OF DETENTION POND REQUIRED BY PALMER LAKE. | SHELLEY | SHELLEY | | B= | P | 3387646 |
TANDEM ENTERPRISES INC | B= | P | 03/15/2007 | SMOKE BARRIERS IN FRONT OF ELEVATORS / SHAFTS IN CLOSETS NOT DONE / NEED TO CHECK CORRIDOR GOING TO EXERCISE ROOM / OCCUPANCY SIGN IN MEETING ROOM / STEEL BEAM NOT WRAPPED IN HALLWAY DOWNSTAIRS / PENETRATIONS NOT SEALED FAR WEST END CORRIDOR UPSTAIRS / NEED MECHANICAL FINAL SIGNED OFF | JOND | JOND | | B= | P | 3387639 |
TANDEM ENTERPRISES INC | BSP | T | 03/02/2007 | PAID (REC#740876)ADDITIONAL PLAN REVIEW TIME: $100.000 From: TIMC Revised plans | TIMC | TIMC | | BSP | T | 3387631 |
TANDEM ENTERPRISES INC | BFR | P | 02/28/2007 | FRAMING FOR NEW DOORS IN MEETING ROOM OK | JOND | JOND | | BFR | P | 3387623 |
TANDEM ENTERPRISES INC | BSP | R | 02/26/2007 | ABOVE CEILING IN UPPER HALLWAY AND LOWER HALLWAY / 2 MECHANICAL PIPES ONE ON WEST END AND ONE ON EAST END AT UPPER HALLWAY NOT SEALED / STEEL BEAM STILL EXPOSED IN LOWER HALLWAY / CLOSET AREAS WITH MECHANICAL STILL NOT ADDRESSED | JOND | JOND | | BSP | R | 3387615 |
TANDEM ENTERPRISES INC | B= | R | 02/07/2007 | JUST DID A PRE-FINAL SHOWING SUPERINTENDANT WHAT TO LOOK FOR AT FINAL INSPECTION | JOND | JOND | | B= | R | 3387608 |
TANDEM ENTERPRISES INC | BSP | R | 02/05/2007 | REJECT CEILING IN UPPER HALLWAY - SEAL ALL PENETRATIONS / NEED COVERS ON EXPOSED BOXES / NEED FIRE DOORS INSTALLED ON 2 ACCESSES TO ATTIC / NEED TO SEE FAR WEST END, NEED LADDER SET UP SO I CAN SEE THIS AREA BY THE STAIRS | JOND | JOND | | BSP | R | 3387600 |
HOGAN MECHANICAL, INC. | BSP | R | 02/02/2007 | ADDITIONAL PLAN REVIEW TIME: $50.000 FROM: DARYL ADDITIONAL PLAN REVIEW TIME PD 02-02-07 | DARYL | DARYL | | BSP | R | 3387765 |
TANDEM ENTERPRISES INC | BSP | T | 02/02/2007 | PAID (REC#735101)ADDITIONAL PLAN REVIEW TIME: $150.000 From: TIMC remove fire walls at walk-way | TIMC | TIMC | | BSP | T | 3387592 |
TANDEM ENTERPRISES INC | BSP | P | 01/24/2007 | ? ON SEPERATION AT CEILING ABOVE MEETING ROOM, WHETHER OR NOT YOU CAN HAVE AN EXPOSED STEEL BEAM, REGIONAL SET OF PLANS WERE DOWN AT REGIONAL GETTING REVISED, NEED ELECTRICAL SIGNED OFF | JOND | JOND | | BSP | P | 3387584 |
TANDEM ENTERPRISES INC | BFR | P | 11/27/2006 | NEED HV AND HI INSPECTIONS COMPLETE | DALE | DALE | | BFR | P | 3387576 |
TANDEM ENTERPRISES INC | BIN | C | 11/27/2006 | | DALE | DALE | | BIN | C | 3387567 |
TANDEM ENTERPRISES INC | BFR | P | 11/22/2006 | LOWER LEVEL OK | DALE | DALE | | BFR | P | 3387559 |
TANDEM ENTERPRISES INC | BIN | P | 11/22/2006 | EVERYTHING OK EXCEPT LOWER LEVEL, NORTH WALL | DALE | DALE | | BIN | P | 3387551 |
TANDEM ENTERPRISES INC | BFR | P | 11/21/2006 | TRUSSES OK, NEED FHA'S ON INTERIOR BEARING WALLS 2ND FLOOR | DALE | DALE | | BFR | P | 3387543 |
TANDEM ENTERPRISES INC | BFR | P | 11/20/2006 | OUTSIDE WALLS UPSTAIRS OK, LOWER OUTSIDE WALLS OK, ELE. WALLS OK | DALE | DALE | | BFR | P | 3387535 |
TANDEM ENTERPRISES INC | BSP | T | 11/13/2006 | PAID (REC#725541)ADDITIONAL PLAN REVIEW TIME: 2 REVIEWS $100.00 | RICH | RICH | | BSP | T | 3387520 |
TANDEM ENTERPRISES INC | BSP | T | 11/13/2006 | PAID (REC#725543)ADDITIONAL PLAN REVIEW TIME: $150.000 From: RUSSELL Revised mechanical plan layout, 4 reviews | RUSSELL | RUSSELL | | BSP | T | 3387527 |
HOGAN MECHANICAL, INC. | BSP | T | 11/13/2006 | PAID (REC#724790)ADDITIONAL PLAN REVIEW TIME: $50.000 From: LARRY Revised plumbing plan | LARRY | LARRY | | BSP | T | 3387758 |
TANDEM ENTERPRISES INC | BSP | T | 10/16/2006 | PAID (REC#723163)ADDITIONAL PLAN REVIEW TIME: $50.000 From: SHELBY | SHELBY | SHELBY | | BSP | T | 3387511 |
TANDEM ENTERPRISES INC | BLA | C | 10/13/2006 | | JOND | JOND | | BLA | C | 3387505 |
TANDEM ENTERPRISES INC | BSP | P | 09/25/2006 | SHEER WALL OK AT INTERIOR / HALLWAY DOWNSTAIRS OK TO DRYWALL LID | JOND | JOND | | BSP | P | 3387496 |
TANDEM ENTERPRISES INC | BSP | P | 09/14/2006 | EXTERIOR PLYWOOD OK | JOND | JOND | | BSP | P | 3387489 |
TANDEM ENTERPRISES INC | BSP | P | 08/22/2006 | 2 NEW 36" PADS OK | JOND | JOND | | BSP | P | 3387479 |
TANDEM ENTERPRISES INC | BFT | C | 08/08/2006 | 72 X 72 PAD - OK TO POUR / FOOTER AND FOUNDATION POURED WITH MAIN BUILDING | MICHAELA | MICHAELA | | BFT | C | 3387470 |
KURT EHRHARDT CONSTRUCTION CORP | BE | C | 03/26/2003 | TO EXTEND PERMIT | DAVEL | DAVEL | | BE | C | 3387240 |
KURT EHRHARDT CONSTRUCTION CORP | BSP | P | 10/08/2002 | INTERIOR FOOTINGS AND PADS | PHIL | PHIL | | BSP | P | 3387232 |
KURT EHRHARDT CONSTRUCTION CORP | BSP | P | 09/16/2002 | FOUNDATION WALL FOR ELEVATOR | PHIL | PHIL | | BSP | P | 3387225 |
KURT EHRHARDT CONSTRUCTION CORP | BSP | P | 09/12/2002 | ELEVATOR PAD | PHIL | PHIL | | BSP | P | 3387218 |
KURT EHRHARDT CONSTRUCTION CORP | BSP | R | 09/11/2002 | ELEVATOR PAD NOT READY | PHIL | PHIL | | BSP | R | 3387208 |
KURT EHRHARDT CONSTRUCTION CORP | BFN | P | 09/04/2002 | STILL NEED REST OF INTERIOR PADS | PHIL | PHIL | | BFN | P | 3387202 |
KURT EHRHARDT CONSTRUCTION CORP | BFD | C | 08/30/2002 | | PHIL | PHIL | | BFD | C | 3387195 |
KURT EHRHARDT CONSTRUCTION CORP | BFT | P | 08/27/2002 | frost trench | PHIL | PHIL | | BFT | P | 3387186 |
KURT EHRHARDT CONSTRUCTION CORP | BFN | P | 08/22/2002 | 3- 30'' PADS, AND BACK WALL | PHIL | PHIL | | BFN | P | 3387178 |
KURT EHRHARDT CONSTRUCTION CORP | BFN | P | 08/02/2002 | CANCEL | PHIL | PHIL | | BFN | P | 3387170 |
KURT EHRHARDT CONSTRUCTION CORP | BFT | P | 07/10/2002 | back section | PHIL | PHIL | | BFT | P | 3387163 |
D & J QUALITY ELECTRIC INC | E= | C | 03/02/2007 | CONTRACTOR REPLACED THE 2 STAIRWELL WALL LIGHTS IN QUESTION ABOUT THIER UL LISTING WITH NEW LIGHTS. | DEAN | DEAN | | E= | C | 3387462 |
D & J QUALITY ELECTRIC INC | E= | R | 02/26/2007 | ALL CORRECTIONS NOT MADE, STILL HAVE INCORRECT PANEL SCHEDULE FAR RIGHT PANEL IN BASEMENT, NEED TO COVER PHOTO CELL FOR OUTSIDE LIGHTS, RBD HAS STARTED A FIELD REPORT WITH UL TO DETERMINE LISTING OF 2 STAIRWELL LIGHTS. ----------------------3 RTU'S 45-AMP AND 1 RTU 60-AMP OK---------------- | DEAN | DEAN | | E= | R | 3387455 |
D & J QUALITY ELECTRIC INC | E= | P | 02/06/2007 | TOO MUCH TO LIST, SEE PERMIT LOG. | DEAN | DEAN | | E= | P | 3387447 |
D & J QUALITY ELECTRIC INC | E= | P | 02/02/2007 | GROUND SCONCES IN CORRIDORE, GROUND STAIRWELL LIGHTS (UL STICKER LOOKS FUNNY; NO GROUNDING MEANS FOR FIXTURE), MISSING EM LIGHT AND EXIT SIGN MISSING SECOND FLOOR BY ELEVATORS, BATH LIGHT ON GFCI CIRCUIT IN ROOM 214, 211 AND 218 NEED MATTRESSES REMOVED FOR INSPECTION----- INSPECTED SECOND FLOOR AND ROOMS 101 AND 112A ONLY ----- | MATTHEW | MATTHEW | | E= | P | 3387440 |
TANDEM ENTERPRISES INC | EE | C | 02/01/2007 | ELECTRICAL 50.00 JM PLAN CHECK FEE | ANGELA | ANGELA | | EE | C | 3387687 |
TANDEM ENTERPRISES INC | EE | T | 02/01/2007 | PAID (REC#735101)ELECTRICAL PLAN REVIEW 50.00 JM | ANGELA | ANGELA | | EE | T | 3387695 |
D & J QUALITY ELECTRIC INC | E= | P | 01/24/2007 | CEILING OF THE LOWER LEVEL MEETING ROOM OK TO CLOSE. | DEAN | DEAN | | E= | P | 3387432 |
D & J QUALITY ELECTRIC INC | EUG | P | 11/03/2006 | ALL SITE LIGHTING UNDERGROUND ON NORTH SIDE OF BUILDING OK. | DEAN | DEAN | | EUG | P | 3387425 |
D & J QUALITY ELECTRIC INC | ER | P | 11/03/2006 | RECESSED CANS OK | DEAN | DEAN | | ER | P | 3387417 |
D & J QUALITY ELECTRIC INC | ER | P | 10/24/2006 | ---------INSTALL GROUND TAIL IN 2 GANG SW BY DOOR OF ROOM 3 ON LOWER LEVEL------------ALL SUITES OK, ALL HALL AND COMMON AREAS WALL AND HARD LIDS OK, STILL NEED CEILING FOR DROP AREAS. | DEAN | DEAN | | ER | P | 3387409 |
D & J QUALITY ELECTRIC INC | ER | P | 10/23/2006 | ROOMS AND HARD LID AREAS MARKED ON PERMIT. | DEAN | DEAN | | ER | P | 3387393 |
D & J QUALITY ELECTRIC INC | ES | C | 10/23/2006 | COMMERCIAL SERVICE: 600-AMP 4 WIRE FEEDER FROM MAIN SERVICE IN HOTEL BY D&J ELEC. | DEAN | DEAN | | ES | C | 3387386 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 04/24/2007 | BALANCE REPORT RECEIVED. | NANCY | NANCY | | H= | C | 3387325 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 04/18/2007 | LOOKING AT BALANCE REPORT. | NANCY | NANCY | | H= | P | 3387314 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 04/17/2007 | ROOM 209 SECURE ANGLES TO BOTH DUCT AND STRUCTURE IF ANGLES ARE ONLY ON ONE SIDE. INSTALL P-TRAPS ON ALL ROOFTOPS. | NANCY | NANCY | | H= | P | 3387305 |
O.M.A.G.M., INC. | H= | C | 04/17/2007 | | NANCY | NANCY | | H= | C | 3387735 |
HOGAN MECHANICAL, INC. | H= | C | 04/17/2007 | | NANCY | NANCY | | H= | C | 3387779 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 04/12/2007 | INSTALL P-TRAPS ON ROOF TOP UNITS. INSTALL VENT EXTENSIONS ON ROOF TOP UNITS AND PROVIDE PAPERWORK FROM MANUFACTURER REGARDING EXTENSIONS. REMOVE FIRE CAULKING FROM AROUND FIRE DAMPERS ON 2ND FLOOR HALLWAY DIFFUSERS. COMPLETE EXERCISE ROOM. LABEL FIRE DAMPER ACCESS DOORS. NOTE: DUCTS AND FIRE DAMPERS IN CLOSETS OK. | NANCY | NANCY | | HD | P | 3387297 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 04/11/2007 | 2ND FLOOR STAIRWELLS: FIRERATING AT SHEETROCK. INSTALL FIRE DAMPERS AT RATING. FLEX TO DIFFUSERS TOO RESTRICTIVE. ROOM 209: SCREW ANGLES TO DUCT. ROOM 210: SCREW ANGLES TO DUCT. ROOM 201: ACCESS DOORS INSTALLED. | NANCY | NANCY | | HD | P | 3387290 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 03/29/2007 | ROOM 208: EXHAUST AND MAKE-UP AIR DUCTS FOR ELEVATOR EQUIPMENT ROOM OK. SMOKE/FIRES INSTALLED AT CEILING GOING INTO ATTIC. ROOM 201: DUCT OK. STILL NEED TO INSTALL ACCESS DOORS. RETAINING ANGLES FOR DAMPERS ON ONE SIDE ONLY. ROOM 105: DUCT PROPERLY SEALED. OKAY TO ENCLOSE DUCT. | NANCY | NANCY | | HD | P | 3387284 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 03/22/2007 | ROOM 209: NOT READY, SHEET ROCK NOT COMPLETED. ROOM 210: INSTALL FIRE DAMPERS AT CEILING INTO ATTIC. ROOM 216: INSTALL FIRE DAMPERS AT CEILING INTO ATTIC. ROOM 201: OK. | NANCY | NANCY | | HD | P | 3387278 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 03/14/2007 | CONSULTATION INSPECTION. LOOKED AT ASSEMBLIES, FRAMING AND SHEET ROCK ON FIRE CHASES AND CLOSETS. | NANCY | NANCY | | HD | P | 3387272 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 02/12/2007 | COURTESY CALL TO SEE HOW JOB IS PROGRESSING. STILL WAITING ON PRINTS. | NANCY | NANCY | | H= | P | 3387265 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 02/07/2007 | DUCTWORK IN WALKWAY BETWEEN BUILDINGS OK. 2 SUPPLIES, 0 RETURN. | NANCY | NANCY | | HD | P | 3387257 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 02/07/2007 | WALKED JOB WITH CONTRACTOR AND ADDRESSED ISSUES. SEE H16 NOTES FROM 2/6/07. | NANCY | NANCY | | H= | P | 3387247 |
WRIGHT PLBG. & HTG. CO.,INC. | H16 | C | 02/06/2007 | FIRE DAMPERS NOT CORRECTLY INSTALLED IN BUILDING AT ANY POINT. HOLES CUT IN PREROCK IN SEVERAL AREAS DOWNSTAIRS, NO FIRE DAMPERS IN AREAS WHERE THEY PENETRATED 1 HOUR ASSEMBLIES, NO FIRE DAMPERS IN ELEVATOR EQUIPMENT ROOM, NO CEILING IN CLOSETS THAT ARE USED FOR CHASES UPSTAIRS WILL NEED CEILINGS AND FIRE DAMPERS PROPERLY INSTALLED. NO CHASE FOR ELEVATOR EQUIPMENT ROOM MAKE-UP AIR | JACK | JACK | | H16 | C | 3387378 |
WRIGHT PLBG. & HTG. CO.,INC. | H= | R | 02/02/2007 | WRIGHT PLB & HEATING PERMIT WAS VOID BY TANDEM THE GENERAL CONTRACTOR AS OF 11:20 FEB 5, 2007 A NEW PERMIT WILL BE ISSUE TO A NEW CONTRACTOR SOON. | JAN | JAN | | H= | R | 3387370 |
WRIGHT PLBG. & HTG. CO.,INC. | HRR | P | 01/25/2007 | NEED APPROVED PRINTS SHOWING THAT SMOKE AND FIRE DAMPERS FOR SUPPLIES AND RETURN INTO BREEZEWAY HAVE BEEN ELIMINATED. ALSO THERE IS SUPPOSED TO BE A REVISION SHOWING THAT THE RETURN IN THE BREEZEWAY HAS BEEN ELIMINATED. | NANCY | NANCY | | HRR | P | 3387361 |
WRIGHT PLBG. & HTG. CO.,INC. | HD | P | 01/18/2007 | ROOFTOP UNITS INSPECTION ONLY. NEED 10 AWAY OR 3 FEET ABOVE BETWEEN UNIT ECONOMIZERS AND SEWER VENTS AND ROOFTOP EXHAUST VENT HOODS. INSTALL P-TRAPS ON UNITS. | NANCY | NANCY | | HD | P | 3387354 |
WRIGHT PLBG. & HTG. CO.,INC. | HC | C | 01/18/2007 | OK TO RELEASE METER. | NANCY | NANCY | | HC | C | 3387346 |
HOGAN MECHANICAL, INC. | HV | C | 12/13/2006 | WATER HEATER VENTS OK | DOUGR | DOUGR | | HV | C | 3387772 |
WRIGHT PLBG. & HTG. CO.,INC. | HD | P | 12/12/2006 | STILL NEED TO SEE: ROOF TOP UNITS, DUCTS IN CONNECTOR HALLWAY, CONNECTIONS AT FIRE DAMPERS, ELEVATOR ROOM EXAHAUST FAN & TERMINATION, MAIN EXHAUST FAN, WATER HEATER VENTS | DOUGR | DOUGR | | HD | P | 3387337 |
O.M.A.G.M., INC. | HI | C | 12/12/2006 | PLANS CORRECTED - GAS PIPING COMPLETE INSIDE | DOUGR | DOUGR | | HI | C | 3387727 |
O.M.A.G.M., INC. | HI | P | 11/27/2006 | OK TO PROCEED AT OWN RISK ON GAS - PLANS NEED TO MATCH JOB BEFORE FINAL, NOTE - SUPERINTENDANT INDICATED THAT THEY WOULD BE CONNECTING TEMPORARY HEATERS TO THE EXISTING GAS LINES - INSPECTOR INFORMED HIM THAT RBD WOULD NEED TO INSPECT THE TEMP LINES BEFORE BEING CONNECTED & IF THEY WERE MEDIUM PRESSURE THEY WOULD NEED TO BE PRESSURE TESTED | DOUGR | DOUGR | | HI | P | 3387718 |
WRIGHT PLBG. & HTG. CO.,INC. | HD | P | 11/17/2006 | OK TO INSULATE AREAS THAT DON'T CONTAIN MECHANICAL, OK TO SEAL DUCT INSULATION IN ATTIC, HAVE MANY FIRE \ SMOKE SEPERATION ISSUES THAT NEED TO BE RESOLVED, PLANS NEED TO BE RESUBMITTED TO MATCH WHAT WAS INSTALLED | DOUGR | DOUGR | | HD | P | 3387332 |
HOGAN MECHANICAL, INC. | P= | C | 03/09/2007 | | SCOTT | SCOTT | | P= | C | 3387819 |
HOGAN MECHANICAL, INC. | PTO | C | 11/15/2006 | CHECK FOR 4'' END OF LINE CLEANOUT ABOVE TOILET IN SOUTH EAST BASEMENT UNIT ON FINAL. | SCOTT | SCOTT | | PTO | C | 3387810 |
HOGAN MECHANICAL, INC. | PTO | T | 11/06/2006 | PAID (REC#724638): STILL DON'T HAVE APPROVED PLANS. LOST TEST. REINSPECT ALL. | SCOTT | SCOTT | | PTO | T | 3387802 |
HOGAN MECHANICAL, INC. | PTO | R | 11/01/2006 | CANCELLED AT CONTRACTORS REQUEST. | SCOTT | SCOTT | | PTO | R | 3387793 |
HOGAN MECHANICAL, INC. | PTO | R | 10/31/2006 | NOT READY. NEED APPROVED PLANS. GRADE AND STRAP TO CODE. LACKS NAIL PROTECTION. ANCHOR CLOSET FLANGES. EXPOSE UNDERGROUND CHANGES AND GET REVISED TO PLANS. | SCOTT | SCOTT | | PTO | R | 3387789 |
NEWCOMER'S PLUMBING AND HEATING, INC. | PB | P | 10/07/2002 | Need elevator sump drain, rest ok | LEE | LEE | | PB | P | 3387750 |
O.M.A.G.M., INC. | V= | C | 10/11/2007 | SCHINDLER--LABEL CAR LIGHT DISCONNECT--M/R DOOR SIGN--FIRE FINAL | TOM | TOM | | V= | C | 3387743 |