BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 06/08/2007 | Temp CO: UNITS 104,105,204,205: NEED ALL OTHER INSPECTIONS INCLUDING ELECTRICAL, PLUMBING, MECHANICAL, FIRE & ZONING / NEED BUILDING ADDRESS NUMBERS / NEED UNIT NUMBERS / WEATHERSTRIP ALL EXTERIOR DOORS WITH DOOR BOTTOM SWEEPS / INSTALL BATHTUB ENCLOSURES / BALCONY BALUSTER SPACING OVER 4" / TRIM MISSING UNDER BALCONY DOOR / NEED POST TENSIONED SLAB CABLE PULL LETTER FROM ENGINEER. | HEATHER | HEATHER | | B= | P | 3392705 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | C | 06/06/2007 | | LEEG | LEEG | | B= | C | 3393297 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 05/31/2007 | NEED HANDRAIL ON STAIRS OF SIDEWALK OUTSIDE UNIT 104. | LEEG | LEEG | | B= | P | 3393290 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 05/08/2007 | ALL UNITS OKAY / SEAL ALL EXTERIOR WALL PENETRATIONS AT WIRES, GAS PIPES AT METERS & AIR CONDITIONING LINE SETS / FIRE CAULK PENETRATIONS INSIDE FIRE RISER CLOSET AND DOMESTIC WATER PIPE CLOSETS / ADA PROTECTION UNDER STAIRS / NEED HANDRAIL BOTH SIDES BREEZWAY STAIRS / NEED FIRE FINAL. | LEEG | LEEG | | B= | P | 3393283 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 05/07/2007 | UNIT 208 OKAY. OFFICE LOCKED AND NO ACCESS TO PERMIT TO SIGN. | LEEG | LEEG | | B= | P | 3393277 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | R | 05/04/2007 | UNIT 208 REPLACE SMOKE DECTECTOR IN LOWER LEVEL BEDROOM. | LEEG | LEEG | | B= | R | 3393271 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 05/04/2007 | UNIT 307 OKAY. | LEEG | LEEG | | B= | P | 3393264 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 05/03/2007 | UNIT 201 OKAY. | LEEG | LEEG | | B= | P | 3393257 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 05/03/2007 | UNITS 101,108, 202, 207, 302, 303 & 306 OKAY. UNIT 208 BALCONY PICKET SPACING OVER 4" APART / LOWER LEVEL BEDROOM SMOKE DETECTOR NOT WORKING PROPERLY. UNIT 307 FURNACE ROOM CEILING HAS OPENINGS REQUIRING DRYWALL AND FIRE CAULK. | LEEG | LEEG | | B= | P | 3393251 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | R | 05/02/2007 | UNIT 201 MISSING HANDRAIL AT UPPER STAIRS. | LEEG | LEEG | | B= | R | 3393240 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 05/02/2007 | INSIDE OF UNITS 107, 204, 102, 205, 203 & 206 OKAY. NEED ALL OTHER REQUIRED INSPECTIONS. | LEEG | LEEG | | B= | P | 3393234 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | R | 05/01/2007 | UNIT 105 OKAY, UNIT 106 OKAY, UNIT 107 MISSING SMOKE DETECTORS. NEED ALL OTHER INSPECTIONS. | LEEG | LEEG | | B= | R | 3393224 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | R | 04/30/2007 | UNIT 103 OKAY. UNIT 104 OKAY. UNIT 204 BALCONY PICKETS SPACED OVER 4" / SEAL DRYWALL JOINTS IN FURNACE CLOSET CEILING AND WALL. NEED ALL OTHER FINALS. | LEEG | LEEG | | B= | R | 3393218 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | R | 04/18/2007 | UNITS 104,105,204,205: NEED ALL OTHER INSPECTIONS INCLUDING ELECTRICAL, PLUMBING, MECHANICAL, FIRE & ZONING / NEED BUILDING ADDRESS NUMBERS / NEED UNIT NUMBERS / WEATHERSTRIP ALL EXTERIOR DOORS WITH DOOR BOTTOM SWEEPS / INSTALL BATHTUB ENCLOSURES / BALCONY BALUSTER SPACING OVER 4" / TRIM MISSING UNDER BALCONY DOOR / NEED POST TENSIONED SLAB CABLE PULL LETTER FROM ENGINEER. | LEEG | LEEG | | B= | R | 3393211 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | R | 04/17/2007 | ATTIC INSULATION INSPECTION TO BE PERFORMED AT FINAL INSPECTION. | LEEG | LEEG | | BIN | R | 3393204 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 03/21/2007 | PARTY WALL PENETRATION FIRE CAULKING ALL UNITS OKAY. | LEEG | LEEG | | BSP | P | 3393198 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 03/13/2007 | INTERIOR DRYWALL NAILING OKAY UNITS 201 AND 208. | LEEG | LEEG | | BSP | P | 3393191 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 03/09/2007 | INTERIOR DRYWALL NAILING OKAY UNITS 101, 102, 107, 108, 202 & 207. | LEEG | LEEG | | BSP | P | 3393183 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 03/07/2007 | EXTERIOR FIRE RISER CLOSET FRAMING EAST SIDE OKAY. | LEEG | LEEG | | BFR | P | 3393175 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 03/07/2007 | DRYWALL NAILING END A2 UNIT PORCH CEILINGS AND BALCONY CEILINGS 2ND & 3RD FLOORS ALL OKAY. | LEEG | LEEG | | BSP | P | 3393169 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 03/06/2007 | DRYWALL NAILING OKAY UNITS 302 AND 307 PLUS BREEZEWAY CEILINGS ALL FLOORS OKAY | LEEG | LEEG | | BSP | P | 3393162 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 03/06/2007 | UNITS 101 AND 108 OKAY. | LEEG | LEEG | | BIN | P | 3393154 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 03/06/2007 | UNITS 101 AND 108 FRAME AND R-C CHANNEL OKAY. | LEEG | LEEG | | BFR | P | 3393145 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 03/05/2007 | UNITS 201 & 208 OKAY. | LEEG | LEEG | | BIN | P | 3393138 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 03/05/2007 | UNITS 201 & 208 OKAY | LEEG | LEEG | | BFR | P | 3393129 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 03/05/2007 | INTERIOR DRYWALL SHEAR NAILING OKAY UNITS 103 & 106. | LEEG | LEEG | | BSP | P | 3393122 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | R | 03/02/2007 | DRYWALL SHEAR UNIT 103 NOT FASTENED PER SHEDULE. | LEEG | LEEG | | BSP | R | 3393114 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 03/02/2007 | UNITS 102 & 107 FRAME AND R-C CHANNEL OKAY. | LEEG | LEEG | | BFR | P | 3393098 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 03/02/2007 | UNITS 102 & 107 OKAY. | LEEG | LEEG | | BIN | P | 3393106 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 03/01/2007 | FRME AND R-C CHANNEL OKAY UNITS 202 & 207. | LEEG | LEEG | | BFR | P | 3393089 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 03/01/2007 | UNITS 202 & 207 OKAY. | LEEG | LEEG | | BIN | P | 3393078 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 03/01/2007 | INTERIOR DRYWALL SHEAR OKAY UNITS 203, 206, 303 & 306. | LEEG | LEEG | | BSP | P | 3392698 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 02/27/2007 | UNITS 302 & 397 OKAY. | LEEG | LEEG | | BFR | P | 3392690 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 02/27/2007 | UNITS 302 & 307 OKAY. | LEEG | LEEG | | BIN | P | 3392682 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 02/26/2007 | INTERIOR DRYWALL SHEAR OKAY UNITS 104, 105, 204 & 205. | LEEG | LEEG | | BSP | P | 3392674 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 02/26/2007 | UNITS 103 & 106 OKAY. | LEEG | LEEG | | BIN | P | 3392666 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 02/26/2007 | UNITS 103 & 106 OKAY TO ROCK. | LEEG | LEEG | | BFR | P | 3392658 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 02/23/2007 | OK TO ROCK UNITS 203 AND 206 | BLAINE | BLAINE | | BIN | P | 3392650 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 02/23/2007 | INTERIOR SHEAR OK 203 AND 206 | BLAINE | BLAINE | | BFR | P | 3392642 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 02/22/2007 | OK TO ROCK 303 AND 306, HAT CHANNEL AND INSULATION OK | CHRISM | CHRISM | | BFR | P | 3392634 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 02/20/2007 | UNITS 104, 105, 204 & 205 OKAY. | LEEG | LEEG | | BIN | P | 3392626 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 02/20/2007 | UNITS 104, 105, 204 & 205 OKAY. | LEEG | LEEG | | BFR | P | 3392618 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 02/16/2007 | ENTRY SIGN BOND BEAM OKAY TO POUR. | LEEG | LEEG | | BSP | P | 3393070 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | T | 02/16/2007 | PAID (REC#737169)ADDITIONAL PLAN REVIEW TIME: $50.000 From: RICH revised res checks | RICH | RICH | | BSP | T | 3393052 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | T | 02/16/2007 | PAID (REC#737171)ADDITIONAL PLAN REVIEW TIME: $50.000 FROM: RUSSELL REVISED MECHANICAL PLANS FOR A1 & A2 UNITS | RUSSELL | RUSSELL | | BSP | T | 3393060 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | R | 02/15/2007 | FIRESTOPPING: REVIEWED WITH CONTRCTORS FLUE PENETRTIONS AND FIRE COLLAR INSTALLATION REQUIREMENTS FROM MANUFACTURER HILTI CORP. | LEEG | LEEG | | BSP | R | 3393040 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 02/09/2007 | ADDED METER CLOSET AT EAST SIDE MID-BUILDING. FOUNDATION WITH SLAB OKAY TO POUR. STAMPED ENGINEERING FOR ADDED CLOSET TO BE PROVIDED FOR RBD FILE. | LEEG | LEEG | | BSP | P | 3393032 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 02/07/2007 | INTERIOR PARTY WALLS ONLY OKAY TO SHEAR. | LEEG | LEEG | | BIN | P | 3393024 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 02/06/2007 | ALL ROOF AND FLOOR TRUSS REPAIRS COMPLETE AND TRUSS DETAILS WITH INSPECTOR. | LEEG | LEEG | | BFR | P | 3393015 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 02/06/2007 | FIRST FLOOR EXTERIOR WALLS: TOP PLATES AT AIR CONDITIONING LINE HOLES TO BE REPAIRED. OKAY TO INSULATE. | LEEG | LEEG | | BFR | P | 3393008 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 02/01/2007 | FIRST FLOOR EXTERIOR BEARING WALLS: STOPPED INSPECTION AFTER TWO UNITS NORTH OF BREEZEWAY. STUD POSTS AT SIDE OF HEADERS . SEE PREVIOUS INSPECTIONS FOR ADDITIONAL CORRECTIONS UPPER FLOORS. | LEEG | LEEG | | BFR | R | 3392611 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/31/2007 | THIRD AND SECOND FLOOR EXTERIOR BEARING WALLS: SISTER NOTCHED STUDS / STRAP TOP PLATES AT LINE SETS. | LEEG | LEEG | | BFR | P | 3392997 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/30/2007 | INTERIOR PARTY WALL FRAME OKAY / FIRE CAULK AND DRAFT STOP INSIDE WALLS OKAY. OKAY TO INSULATE PARTY WALLS. | LEEG | LEEG | | BFR | P | 3392989 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/25/2007 | MAIN FLOOR DRAFT STOPS AND FIRE STOPS INSPECTED AND APPROVED FOR APLICATION OF SHEAR PANELS AND INSULATION. STUD SPACING, ANCHOR BOLTS AND POINT LOADS OKAY. THIS INSPECTION FOR INTERIOR PARTY WALLS ONLY. | LEEG | LEEG | | BFR | P | 3392981 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/24/2007 | FIRST FLOOR DOUBLE WALL DRAFT STOP AND FIRE STOP. REPAIR SEVERAL HOLES AND RE-CALL INSPECTION. | LEEG | LEEG | | BFR | R | 3392974 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/23/2007 | RC-1 CHANNEL AT ALL EXTERIOR CEILINGS OKAY. | LEEG | LEEG | | BFR | P | 3392965 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/22/2007 | ALL ROOF TRUSSES OKAY. | LEEG | LEEG | | BFR | P | 3392958 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/19/2007 | BALCONY FRAMING OKAY. ENGINEERS LETTER OF APPROVAL FOR JOIST HANGER SUBSTITUTION WITH INSPECTOR. | LEEG | LEEG | | BFR | P | 3392950 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/19/2007 | ROOF TRUSSES ONLY: UNIT 205 REPAIR FOR B1AR DAMAGED BY DUCT INSTALLATIN - REPLACE SCAB PER DETAIL. IN UNITS B302, B303, B306 & B307 TRUSSES HG AT BEARING WALLS BLOCK TALL HEELS , INSTALL H2.5 TRUSS CLIPS AND INSTALL H2.5 TRUSS CLIPS AT G2 & G TRUSSES AT NG GIRDERS. | LEEG | LEEG | | BFR | R | 3392942 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/18/2007 | BALANCE OF FLOOR TRUSSES: B 2 STAIR LANDING HEADER JOIST NOT SUPPORTED PROPERLY - NEED FLOOR JOIST DESIGN FOR HANGER POINT LOAD / NAIL AND BLOCK JOIST HANGERS AT B2 LOFT / JOIST REPAIR AT MAIN FLOOR FIRE CLOSET SOUTHWEST CORNER / A 108 FLOOR JOIST REPAIR LETTER FOR JOIST ABOVE FIREPLACE AND BETWEEN FAMILY ROOM & BEDROOM / NEED LETTER FOR DAMAGED PLATE AT TOP CHORD TO WEB. | LEEG | LEEG | | BFR | R | 3392934 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/18/2007 | TRUSS REPAIR UNIT 208 BALCONY COMPLETE. | LEEG | LEEG | | BFR | P | 3392927 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/18/2007 | FLOOR TRUSS REPAIRS NOT COMPLETED PER ENGINEERS DESIGN. | LEEG | LEEG | | BFR | R | 3392920 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/16/2007 | TRUSS REPAIR FOR UNIT 208 BALCONY NOT PER REPAIR DETAIL. | LEEG | LEEG | | BFR | R | 3392912 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/16/2007 | FLOOR TRUSSES NORTH END ONLY. TRUSS REPAIR NOT PER DETAIL / TOP CHORD TRUSS PLATE DAMAGED AT BEARING WALL EAST END LOWER LEVEL / TIE OFF STRONGBACKS AND RIBBON TIE ENDS AND SPLICE BREAKS. | LEEG | LEEG | | BFR | R | 3392903 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/04/2007 | SOUTH AND NORTH ENDS A2 PORCHES AND BALCONY ROOF TRUSSES: ALL OKAY EXCEPT ONE (1) DAMAGED, SPLIT BOTTOM CHORD UNIT 208 SOUTH WEST CORNER, PROVIDE REPAIR LETTER. | LEEG | LEEG | | BFR | R | 3392896 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 01/04/2007 | BREEZEWAY ROOF TRUSSES, BEAMS AND FLOOR TRUSSES OKAY. | LEEG | LEEG | | BFR | P | 3392887 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 01/03/2007 | BREEZEWAY TRUSSES, A-1 UNITS NORTH ENDS AT BALCONIES: BREEZEWAY TRUSSES NEED CLIPS AT TALL ENDS , TIE MICROLAM BEAM ENDS TO WALLS / BALCONY AND ENTRY TRUSSES NORTH END OKAY. | LEEG | LEEG | | BFR | R | 3392880 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | R | 12/15/2006 | ROOF TRUSS INSPECTION NORTH HALF: TRUSS CHANGES NOT DETAILED ON APPROVED PLANS / TRUSS LATERAL BRACES MISSING / BOTTOM CHORD LOADED FOR STAIR LANDING SUPPORT - TRUSS NOT ENGINEERED FOR LOAD / GIRDER TRUSS OVERLOADED AT INTENDED BEARING WALLS. DID NOT COMPLETE INSPECTION OF TRUSSES. | LEEG | LEEG | | BSP | R | 3392872 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 12/04/2006 | SHEAR ON REST OF BLDG. OK | DALE | DALE | | BSP | P | 3392865 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/30/2006 | UNIT 103, 104, 105, 106, 203, 204, 205, 206, 303 AND 306 SHEAR OK | DALE | DALE | | BSP | P | 3392858 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/27/2006 | EXTERIOR SHEAR 2ND & 3RD FLOOR BREEZEWAYS OKAY. INTERIOR SHEAR BEHIND BATHTUBS 2ND & 3RD FLOORS OKAY. | LEEG | LEEG | | BSP | P | 3392835 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/27/2006 | INSULATION AND PRE-ROCK BEHIND BATH TUBS AT 2ND & 3RD FLOORS OKAY. | LEEG | LEEG | | BSP | P | 3392842 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/27/2006 | INTERIOR SHEAR AT PLANT SHELVES 2ND & 3RD FLOORS OKAY. INSULATION AT EXTERIOR WALLS OF FOUR (4) MECHANICAL ROOMS AT A-1 2ND FLOOR OKAY. | LEEG | LEEG | | BSP | P | 3392851 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/17/2006 | FOUNDATION FOR PROJECT ENTRY SIGN OKAY. DOWELS FOR MASONRY TO BE WET SET AFTER POUR. | LEEG | LEEG | | BSP | P | 3392826 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/16/2006 | OK PRESHEAR ( INTERIOR ) UNITS; 101 - 108 | BOBB | BOBB | | BSP | P | 3392818 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/16/2006 | OK SHEAR FOR 1ST FLOOR BREEZEWAY. | BOBB | BOBB | | BSP | P | 3392810 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/16/2006 | OK INSULATION & SHEAR FOR PLANT SHELFS, TUBS , & 4- MECHANICAL ROOMS FOR A-UNITS , 101 - 108 | BOBB | BOBB | | BSP | P | 3392802 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/14/2006 | ENTRANCE SIGN FOOTINGS OKAY. | LEEG | LEEG | | BSP | P | 3392794 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/03/2006 | UPPER FLOOR BALCONY BEAMS AND POSTS OKAY. NEED LETTER FOR JOIST, LEDGER, JOIST HANGERS & LDGER BOLTS. | LEEG | LEEG | | BSP | P | 3392788 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/03/2006 | MAIN FLOOR BALCONY BEAMS POSTS AND ANCHOR BOLTS OKAY. NEED ENGINEER LETTER FOR JOIST, LEDGER, JOIST HANGER, LEDGER BOLTS. | LEEG | LEEG | | BSP | P | 3392780 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | R | 11/02/2006 | LOWER LEVEL BALCONY FRAMES: ANCHOR BOLTS OKAY / HEADERS OKAY / SOME JOIST MISSING / SOME HANGERS MISSING / SOME LEDGER BOLTS MISSING. | LEEG | LEEG | | BSP | R | 3392771 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | R | 10/16/2006 | EXTERIOR SHEAR: NEED ALL HARDWARE AND NAILING PER PLANS. THIS INSPECTION WAS FIRST TIME WALK THROUGH OF STRUCTURE TO DETERMINE SEQUENCE AND EXTENT OF EACH INSPECTION. | LEEG | LEEG | | BSP | R | 3392763 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFN | C | 09/11/2006 | POST TENSION SLAB FOR CONDOS | MELANIE | MELANIE | | BFN | C | 3392756 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFI | C | 09/11/2006 | POST TENSION SLAB FOR CONDOS | MELANIE | MELANIE | | BFI | C | 3392745 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFI | P | 09/06/2006 | NORTH 25% ONLY OKAY. | LEEG | LEEG | | BFI | P | 3392738 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFN | P | 09/06/2006 | NORTH 25% ONLY. NEED PULL REPORT FOR CABLES. | LEEG | LEEG | | BFN | P | 3392730 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFI | R | 09/05/2006 | CANCELLED IN FIELD BY RICK. RESCHECK REQUIRES R-5 PERIMETER INSULATION. RESCHECK DOES NOT HAVE ANY HEAT LOSS FOR SLAB PERIMETER. | LEEG | LEEG | | BFI | R | 3392722 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFT | C | 08/17/2006 | GRADE BEAM AND UFER GROUND OK / NEED POST TENSION REPORT | ANDY | ANDY | | BFT | C | 3392713 |
BRILLIANT ELECTRIC, LLC | E= | C | 05/07/2007 | 8 AC UNITS INSTALLED | THOMAS | THOMAS | | E= | C | 3393538 |
BRILLIANT ELECTRIC, LLC | E= | P | 05/04/2007 | UNITS: 101, 102, 203, 208 ARE OK, NOTE! NO A/C'S ON ANY UNITS AT THIS TIME | GARYL | GARYL | | E= | P | 3393530 |
BRILLIANT ELECTRIC, LLC | E= | P | 04/23/2007 | UNITS 201, 108 OK | GARYL | GARYL | | E= | P | 3393522 |
BRILLIANT ELECTRIC, LLC | E= | P | 04/12/2007 | 107,207,307 OK | GARYL | GARYL | | E= | P | 3393515 |
BRILLIANT ELECTRIC, LLC | E= | P | 04/11/2007 | UNITS 202, 205, AND 206 OK | MATTHEW | MATTHEW | | E= | P | 3393507 |
BRILLIANT ELECTRIC, LLC | E= | P | 04/10/2007 | 105,204,306 | MIKEC | MIKEC | | E= | P | 3393499 |
BRILLIANT ELECTRIC, LLC | E= | P | 04/09/2007 | 106 OK. NO AC'S AT THIS TIME. 204 AND 306 NOT READY. | ROBERT | ROBERT | | E= | P | 3393491 |
BRILLIANT ELECTRIC, LLC | E= | P | 04/06/2007 | 103,104,302,303 | MIKEC | MIKEC | | E= | P | 3393483 |
BRILLIANT ELECTRIC, LLC | ES | C | 01/23/2007 | COMMERCIAL SERVICE: 1200A, 3-WIRE, U/G, FOR METERS: 101-108 201-208, 302, 303, 306, 307, AND HSE, BRILLIANT ELECT | GARYL | GARYL | | ES | C | 3393476 |
BRILLIANT ELECTRIC, LLC | ER | P | 01/22/2007 | 101 OK. BALCONY CEILINGS 201,204,205,208 OK. | ROBERT | ROBERT | | ER | P | 3393467 |
BRILLIANT ELECTRIC, LLC | ER | P | 01/19/2007 | UNITS: 201,208,108 OK TO COVER UNIT 101 NOT READY | GARYL | GARYL | | ER | P | 3393460 |
BRILLIANT ELECTRIC, LLC | ER | P | 01/09/2007 | UNIT 205 OK TO COVER | GARYL | GARYL | | ER | P | 3393451 |
BRILLIANT ELECTRIC, LLC | ER | P | 01/08/2007 | 104, 105, 204 OK TO COVER, 205 NOT READY | GARYL | GARYL | | ER | P | 3393444 |
BRILLIANT ELECTRIC, LLC | ER | P | 01/05/2007 | | GARYL | GARYL | | ER | P | 3393435 |
BRILLIANT ELECTRIC, LLC | ER | P | 01/03/2007 | NOTE! POC-BRETT 371-0683, UNITS 102, 103, 106, 107 OK | GARYL | GARYL | | ER | P | 3393428 |
BRILLIANT ELECTRIC, LLC | ER | P | 01/02/2007 | UNITS 202--203--206--207 GOOD | THOMAS | THOMAS | | ER | P | 3393420 |
JOHNSON HEATING AND PLUMBING, INC. | H= | C | 05/07/2007 | HVAC FINAL. | LYNNS | LYNNS | | H= | C | 3392596 |
STEEL-T HEATING, INC. | H= | C | 05/07/2007 | | LYNNS | LYNNS | | H= | C | 3392603 |
JOHNSON HEATING AND PLUMBING, INC. | H= | P | 04/27/2007 | UNITS:302, 303, 306 AND 307 COMPLETE. STILL WAITING ON CONDENSERS TO BE SET. | LYNNS | LYNNS | | H= | P | 3392588 |
JOHNSON HEATING AND PLUMBING, INC. | H= | P | 04/26/2007 | HVAC FINALS IN UNITS: 201, 202, 203, 204, 205, 206, 207 AND 208. | LYNNS | LYNNS | | H= | P | 3392581 |
JOHNSON HEATING AND PLUMBING, INC. | H= | P | 04/25/2007 | PARTIAL FOR UNITS 101, 102, 103, 105, 106, 107 AND 108. NEED TO ADD 12 CONDENSERS TO PERMIT AND INSTALL FOR FINAL ON SHELL. | LYNNS | LYNNS | | H= | P | 3392572 |
JOHNSON HEATING AND PLUMBING, INC. | H= | P | 04/24/2007 | UNIT 105 HVAC FINAL. | LYNNS | LYNNS | | H= | P | 3392564 |
BLUE FLAME GAS COMPANY, INC. | H= | C | 04/05/2007 | GAS CONTRACTOR O.K | JOEL | JOEL | | H= | C | 3392469 |
JOHNSON HEATING AND PLUMBING, INC. | HRR | C | 03/07/2007 | NEED TO RE-CHECK RETAINING ANGLE CORNERS AT FINAL. | JIMV | JIMV | | HRR | C | 3392556 |
JOHNSON HEATING AND PLUMBING, INC. | HRP | P | 03/02/2007 | OK FOR UNITS 106-201-307 | TCRIPPEN | TCRIPPEN | | HRP | P | 3392548 |
BLUE FLAME GAS COMPANY, INC. | HC | C | 03/01/2007 | OK FOR METERS, ALL UNITS. | LYNNS | LYNNS | | HC | C | 3392463 |
JOHNSON HEATING AND PLUMBING, INC. | HRP | P | 02/28/2007 | TESTED UNITS 101-103-105-107-108-ARE OK TESTED 203-208-ARE OK TESTED 303-306-ARE OK, /// NEED TO RETEST 106-201-307-/// | TCRIPPEN | TCRIPPEN | | HRP | P | 3392540 |
JOHNSON HEATING AND PLUMBING, INC. | HRP | P | 02/23/2007 | NOT READY FOR UNITS 104 AND 204 | TCRIPPEN | TCRIPPEN | | HRP | P | 3392532 |
JOHNSON HEATING AND PLUMBING, INC. | HRR | P | 02/23/2007 | PARTIAL FOR UNITS 201, 208 NATE REQUSETED THAT ALL MECH ROOMS BE DONE AT FINAL | TCRIPPEN | TCRIPPEN | | HRR | P | 3392525 |
JOHNSON HEATING AND PLUMBING, INC. | HRR | P | 02/22/2007 | ROUGH DUCT AND DIRECT VENTS IN UNITS 202, 207, 102, 302 AND 307 OK. STILL WAITING ON APPROVED PLANS FROM ENGINEER FOR FIRE DAMPER INSTALLATION. | LYNNS | LYNNS | | HRR | P | 3392516 |
JOHNSON HEATING AND PLUMBING, INC. | HRP | P | 02/22/2007 | UNITS 103, 203, 303, 205, 206 AND 207, 410# TESTS OK. | LYNNS | LYNNS | | HRP | P | 3392508 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 02/20/2007 | 10 UNITS ON SOUTH END O.K | JOEL | JOEL | | HI | C | 3392451 |
JOHNSON HEATING AND PLUMBING, INC. | HRP | P | 02/15/2007 | UNITS 104 AND 204, 410# TESTS OK. | LYNNS | LYNNS | | HRP | P | 3392501 |
JOHNSON HEATING AND PLUMBING, INC. | HD | P | 02/15/2007 | UNITS 103, 104, 204 AND 205 ROUGH DUCT COMPLETE. NEED APPROVED PLANS. | LYNNS | LYNNS | | HD | P | 3392493 |
JOHNSON HEATING AND PLUMBING, INC. | HD | P | 02/06/2007 | UNITS 101, 107, 108, 203, 303 AND 304 ROUGH DUCT OK. NEED APPROVED PLANS. | LYNNS | LYNNS | | HD | P | 3392485 |
BLUE FLAME GAS COMPANY, INC. | HI | P | 01/24/2007 | 10 - 10# TESTS AND DESIGN OK FOR NORTH HALF OF BUILDING. | LYNNS | LYNNS | | HI | P | 3392443 |
JOHNSON HEATING AND PLUMBING, INC. | HV | P | 01/16/2007 | MECHANICAL CONTRACTOR. DRYER, EXHAUST FANS, BVENTS ONLY. COMPLETE AFTER PVC VENTING OF 90% FURNACES. | TOMS | TOMS | | HV | P | 3392477 |
A-TOTAL PLUMBING, INC. | P= | C | 05/07/2007 | | LEE | LEE | | P= | C | 3393413 |
A-TOTAL PLUMBING, INC. | P= | R | 05/03/2007 | SUPPLY TO TRAP PRIMER AT WATER METER ROOM PIPED AFTER IRRIGATION ISOLATION VALVE, PEX AGAINST WATER HEATER VENT AT 306, NEED PROPER AIR GAP AT DISH WASHER DRAIN 101, WATER HEATER FLEX CONNECTORS KINKED AT UNIT 101, NEED PROPER AIR GAP AT DISH WASHER DRAIN 108, CAN NOT USE PEX AT T&P DRIP LEG UNIT 204 | JEFF | JEFF | | P= | R | 3393404 |
A-TOTAL PLUMBING, INC. | P= | R | 04/30/2007 | WAIVE TRIP FEE, NOT READY, STOPPED INSPECTION, CONTRACTOR TO VERIFY WORK COMPLETE PRIOR TO CALLING INSPECTION IN, RBD NO TO BE USED AS QUALITY CONTROL, REINSPECT ALL | JEFF | JEFF | | P= | R | 3393394 |
A-TOTAL PLUMBING, INC. | P= | P | 04/27/2007 | NORTH HALF COMPLETE | JEFF | JEFF | | P= | P | 3393387 |
A-TOTAL PLUMBING, INC. | P= | P | 04/26/2007 | UNIT 103 OK---GET NUMBERS UP ON UNIT 105 ----105 AND 204 DIDNT HAVE THE WATER HEATERS LITE!!! ITS 130!! | LYNNIE | LYNNIE | | P= | P | 3393379 |
A-TOTAL PLUMBING, INC. | PTO | C | 02/21/2007 | | JEFF | JEFF | | PTO | C | 3393373 |
A-TOTAL PLUMBING, INC. | PTO | P | 12/13/2006 | LEAK ON 4" STACK AT UNIT 207 PLUS PREVIOUS NOTES, NEED NAIL PROTECTION THROUGHOUT | JEFF | JEFF | | PTO | P | 3393366 |
A-TOTAL PLUMBING, INC. | PTO | P | 12/06/2006 | COMPLETE NAIL PROTECTION, ANCHOR CLOSET FLANGES, PROPERLY GRADE TUB WASTE ABOVE 204, FOR NORTH HALF OF BUILDING ONLY | JEFF | JEFF | | PTO | P | 3393358 |
A-TOTAL PLUMBING, INC. | PB | C | 08/31/2006 | | JEFF | JEFF | | PB | C | 3393350 |
A-TOTAL PLUMBING, INC. | PB | P | 08/25/2006 | A1 TO INCLUDE BATHROOMS IN B2 BOTH SIDES | JEFF | JEFF | | PB | P | 3393342 |