GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | C | 05/13/2008 | | BLAKE | BLAKE | | B= | C | 3675534 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 09/05/2007 | ROOMS 3043 AND 3047 OK-FIRE DEPARTMENT APPROVAL ON FILE | BERTW | BERTW | | B= | P | 3432194 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 08/16/2007 | EP LAB ROOM #3064 AND CORRIDOR OK FIRE DEPT APPROVAL ON FILE | BERTW | BERTW | | B= | P | 3432187 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | C | 07/27/2007 | ROOM 3046 SOFFITS AND WALL FRAMING OK/THIS COMPLETES FRAMING INSPECTIONS ON THIS JOB | BERTW | BERTW | | BFR | C | 3432179 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/10/2007 | ROOM 3047 DROP SOFFIT FRAMING SOUTHWEST CORNER | BERTW | BERTW | | BFR | P | 3432171 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 07/10/2007 | 3RD FLOOR VASCULAR CENTER-CORRIDORS -EXTERIOR ROOMS-LOCKER ROOMS-RECEPTION AREA OK/STILL NEED INSPECTIONS ON X-RAY AND UNFINISHED ROOMS IN CENTER OF UNIT/FIRE FINAL ON FILE | BERTW | BERTW | | B= | P | 3432164 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 06/13/2007 | SHAFT AND SMOKE WALL ROOM #3064 AND DROP SOFFITTS FRAMING ROOM #3034 OK | BERTW | BERTW | | BFR | P | 3432157 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 05/29/2007 | NEED SHAFT WALLS PER PLANS DETAIL G @ LAB ROOM/ OK NORTH WALL FRAMING @ JOB ROOM #3064 SEE PLANS SHEET A102 | BERTW | BERTW | | BFR | P | 3432148 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 05/03/2007 | FLOOR REPAIR FOR SHAFT REMOVAL; STEEL OK; NOTED ON APPROVED PLANS SHEET S101 | DANF | DANF | | BSP | P | 3432138 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 05/03/2007 | SMOKE PARTITIONS AND RATED WALLS IN NEW VASCULAR CENTER NOTED ON SHEET A102; STILL NEED INSPECTION OF NORTH WALL OF LAB AREA | DANF | DANF | | BSP | P | 3432130 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | T | 04/03/2007 | PAID (REC#749042)ADDITIONAL PLAN REVIEW TIME: $50.000 From: RUSSELL Revised mechanical | RUSSELL | RUSSELL | | BSP | T | 3432122 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 02/15/2007 | ALL BUT NEW SHAFT AT NORTH EAST CORNER | TERRYB | TERRYB | | BFR | P | 3432098 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | P | 02/02/2007 | STRUCTURAL SLAB INFILL AREAS SEE SHEET S101 FOR AREAS INSPECTED | BERTW | BERTW | | BFN | P | 3432091 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 02/02/2007 | SEE SHEET A102 FOR WALLS INSPECTED | BERTW | BERTW | | BFR | P | 3432083 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | T | 02/01/2007 | PAID (REC#735070)ADDITIONAL PLAN REVIEW TIME: $50.000 From: RICH revised 2hr wall at electrical room, 90 min door, per NFPA13 | RICH | RICH | | BSP | T | 3432075 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 01/24/2007 | CONSULTATION WITH CONTRACTOR ON SMOKE BARRIERS AND SMOKE PARTITIONS | BERTW | BERTW | | BSP | P | 3432067 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 01/23/2007 | WALLS FRAMING OK/SEE SHEET A102 FOR AREAS INSPECTED | BERTW | BERTW | | BFR | P | 3432060 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 01/18/2007 | WALLS EAST HALF GRIDS E THRU H AND 1 THRU 5 OK /NEED RBD AND FIRE DEPARTMENT APPROVAL ON FIREWALLS @ 2 ELECTRIC EQUIPMENT ROOMS IN LEIU OF SPRINKLER HEAD | BERTW | BERTW | | BFR | P | 3432054 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | P | 01/11/2007 | VASCULAR CENTER___ 3RD FLOOR @ ROOF___ REBAR FOR 6 COLUMNS(PIER CAPS) TO SUPPORT AIR HANDLER UNIT OK TO POUR | BERTW | BERTW | | BFN | P | 3432047 |
GREEN ELECTRIC INC | E= | C | 11/07/2007 | | MIKEC | MIKEC | | E= | C | 3432500 |
GREEN ELECTRIC INC | E= | P | 08/31/2007 | ROOM 3042 | MIKEC | MIKEC | | E= | P | 3432493 |
GREEN ELECTRIC INC | ER | P | 08/31/2007 | | MIKEC | MIKEC | | ER | P | 3432485 |
GREEN ELECTRIC INC | ER | P | 08/15/2007 | CEILING 3014 | MIKEC | MIKEC | | ER | P | 3432477 |
GREEN ELECTRIC INC | E= | P | 08/10/2007 | PROCEDURE ROOM # 1 & INTERIOR CORRIDOR----NEED TO COMPLETE 2 PANEL SCHEDULES----PANEL IN PROCEDURE ROOM GOOD & HALL GOOD | THOMAS | THOMAS | | E= | P | 3432468 |
GREEN ELECTRIC INC | ER | P | 07/25/2007 | WALLS SEE ORANGE CARD | MIKEC | MIKEC | | ER | P | 3432460 |
GREEN ELECTRIC INC | ER | P | 07/11/2007 | WALLS 3064 AND3047 | MIKEC | MIKEC | | ER | P | 3432452 |
GREEN ELECTRIC INC | E= | P | 06/26/2007 | 3RD FLOOR CORRIDORS AND EXTERIOR ROOMS SEE PLANS, ELECTRIC ROOM, RECEPTION AREA AND ROOM ON EAST SIDE NOT READY | BRET | BRET | | E= | P | 3432445 |
GREEN ELECTRIC INC | ER | P | 06/26/2007 | 3043 EP LAB WALL ROUGH | BRET | BRET | | ER | P | 3432436 |
GREEN ELECTRIC INC | ER | P | 05/25/2007 | WALLS E.P 1 | MIKEC | MIKEC | | ER | P | 3432429 |
GREEN ELECTRIC INC | ER | P | 04/17/2007 | CEILINGS EXCEPT PROCEDURE ROOMS | MIKEC | MIKEC | | ER | P | 3432421 |
GREEN ELECTRIC INC | ER | P | 01/29/2007 | REST OF WALLS | MIKEC | MIKEC | | ER | P | 3432412 |
GREEN ELECTRIC INC | ER | P | 01/22/2007 | SEE PLANS | MIKEC | MIKEC | | ER | P | 3432403 |
GREEN ELECTRIC INC | ER | P | 01/17/2007 | SEE HIGHLIGHTED PLANS | MIKEC | MIKEC | | ER | P | 3432396 |
GREEN ELECTRIC INC | ER | P | 11/21/2006 | WALLS GOOD | THOMAS | THOMAS | | ER | P | 3432389 |
COLORADO SHEET METAL CO., INC. | H= | C | 04/30/2008 | RECEIVED BALANCE REPORT. | LYNNS | LYNNS | | H= | C | 3668279 |
COLORADO SHEET METAL CO., INC. | H= | P | 08/23/2007 | HVAC FINAL PENDING BALANCE REPORT. | LYNNS | LYNNS | | H= | P | 3432381 |
COLORADO SHEET METAL CO., INC. | H= | P | 08/10/2007 | PROCEDURE ROOMS 3045, 3043 AND 3047, HVAC FINALS. | LYNNS | LYNNS | | H= | P | 3432373 |
COLORADO SHEET METAL CO., INC. | HD | C | 08/07/2007 | ROUGTH DUCT IN PROCEDURE ROOMS 3 AND 4 OK TO INSULATE. | LYNNS | LYNNS | | HD | C | 3432365 |
COLORADO SHEET METAL CO., INC. | HD | P | 07/26/2007 | PROCEDURE ROOM #2, REGISTERS, GRILLES OK, INTERNAL HALLWAY, REGISTERS OK NEED RETURNS IN YET, PROCEDURE ROOM #4, RETURN AIR DUCT ROUGH COMPLETE. | LYNNS | LYNNS | | HD | P | 3432357 |
COLORADO SHEET METAL CO., INC. | HD | P | 06/27/2007 | ROUGH DUCT IN ROOMS 3047 AND 3043, OK TO INSULATE. | LYNNS | LYNNS | | HD | P | 3432349 |
OLSON PLUMBING & HEATING COMPANY | H= | C | 06/27/2007 | CHILL WATER SUPPLY AND RETURN, STEAM SUPPLY AND RETURN TO RTU'S 1 AND 2. HWP FINAL FOR THIRD FLOOR. | LYNNS | LYNNS | | H= | C | 3432211 |
COLORADO SHEET METAL CO., INC. | HD | P | 06/11/2007 | AHU-1 SUPPLY AND RETURN DUCT COMPLETE. STILL NEED FRESH AIR. | LYNNS | LYNNS | | HD | P | 3432341 |
COLORADO SHEET METAL CO., INC. | HD | P | 05/24/2007 | PROCEDURE ROOM 1: SUPPLY AIR ROUND PIPE OK TO WRAP. PROCEDURE ROOM 1: RETURN AIR'S IN TWO CORNERS COMPLETE, OK TO COVER. 2ND FLOOR: BOTTOM OF NORTH SHAFT RETURN AIR S/F DAMPERS OK. DUCT IS COMPLETE. RTU 2: ROOF DUCT SUPPLY AND RETURN OK TO INSULATE. CHECK INSTALLATION OF LEGS AT LATER INSPECTION. | NANCY | NANCY | | HD | P | 3432333 |
COLORADO SHEET METAL CO., INC. | HD | P | 05/08/2007 | ROUGH DUCT ON FH-2 RISER, FH-1 AND GE-3 ON ROOF, EP LAB 3064 SUPPLY AND RETURN AND 5- FIRE/ SMOKE DAMPERS IN TWO ELECTRICAL ROOMS 3RD FLOOR. | LYNNS | LYNNS | | HD | P | 3432325 |
COLORADO SHEET METAL CO., INC. | H= | P | 04/25/2007 | PARTIAL FINAL FOR PERMITER ROOMS EXCEPT FOR AREAS WHERE RETURN GRILLES ARE MISSING. | LYNNS | LYNNS | | H= | P | 3432317 |
COLORADO SHEET METAL CO., INC. | HD | P | 03/22/2007 | ROUGH DUCT COMPLETE EXCEPT FOR SUPPLY AIR IN CLEAN AIR UTILITY AND RTU RISER TO ROOF. | LYNNS | LYNNS | | HD | P | 3432309 |
COLORADO SHEET METAL CO., INC. | HD | P | 03/07/2007 | SUPPLY AND RETURN LINES IN WEST HALLWAY, EXHAUST AND SUPPLY IN NORTH/ WEST BATHROOMS, LOW PRESSURE ON THE NORTH OK TO COVER. | LYNNS | LYNNS | | HD | P | 3432301 |
OLSON PLUMBING & HEATING COMPANY | HWP | C | 02/14/2007 | 80# TEST ON HEATING WATER SUPPLY AND RETURN LINE LOOP FOR THIRD FLOOR. OK TO INSULATE. | LYNNS | LYNNS | | HWP | C | 3432203 |
COLORADO SHEET METAL CO., INC. | HD | P | 02/08/2007 | DISCUSSION WITH CONTRACTOR AND GENERAL CONTRACTOR'S REP. ON RISER SHAFT AND FIRE WALL PROTECTION. NEED INFORMATION ON EGRESS HALLWAY RATING AND RATING FOR 2- ELECTRICAL ROOMS. QUESTION IF SMOKE WALLS AT HALLWAY FOR EGRESS JUSTIFIES 1 HOUR FIRE RATING. RATING FOR RISER SHAFT STARTS AT FLOOR ON 2ND. NEEDPROTECTION AT THAT POINT. | LYNNS | LYNNS | | HD | P | 3432291 |
COLORADO SHEET METAL CO., INC. | HD | P | 02/02/2007 | PARTIAL ROUGH DUCT ON LOW PRESSURE DOWNSTREAM OF VAV'S OK TO INSULATE. | LYNNS | LYNNS | | HD | P | 3432282 |
COLORADO SHEET METAL CO., INC. | HD | P | 01/16/2007 | MEDIUM AND LOW PRESSURE SUPPLY, OK TO INSULATE. | LYNNS | LYNNS | | HD | P | 3432274 |
COLORADO SHEET METAL CO., INC. | HD | P | 12/04/2006 | MAIN SUPPLY TRUCK LINE AROUND PERIMETER OK TO INSULATE. | LYNNS | LYNNS | | HD | P | 3432266 |
OLSON PLUMBING & HEATING COMPANY | P= | C | 06/29/2007 | | LYNNIE | LYNNIE | | P= | C | 3432258 |
OLSON PLUMBING & HEATING COMPANY | PTO | C | 02/21/2007 | | MARTY | MARTY | | PTO | C | 3432250 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 02/14/2007 | N/WEST BATHROOMS AMB. CARE CENTER. | MARTY | MARTY | | PTO | P | 3432242 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 01/30/2007 | H2 TO SOUTH.PRD H2 TO C6.. | MARTY | MARTY | | PTO | P | 3432234 |
OLSON PLUMBING & HEATING COMPANY | PRD | P | 01/30/2007 | H2 TO C6. | MARTY | MARTY | | PRD | P | 3432228 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 01/16/2007 | COLUMN E SOUTH 3RD FLOOR. | MARTY | MARTY | | PTO | P | 3432218 |