MARK YOUNG CONSTRUCTION, INC. | B= | C | 05/30/2008 | ALL PAPERWORK ON FILE | BERTW | BERTW | | B= | C | 3683804 |
MARK YOUNG CONSTRUCTION, INC. | BFN | C | 05/30/2008 | | BERTW | BERTW | | BFN | C | 3683802 |
MARK YOUNG CONSTRUCTION, INC. | BFT | C | 05/30/2008 | HELICAL REPORT ON FILE | BERTW | BERTW | | BFT | C | 3683800 |
MARK YOUNG CONSTRUCTION, INC. | B= | P | 05/28/2008 | NEED ALL ENGINEERING PER FRAMING NOTES/ALL ELSE OK | BERTW | BERTW | | B= | P | 3682534 |
MARK YOUNG CONSTRUCTION, INC. | B= | R | 05/23/2008 | NO SUPERVISOR ON SITE NO INFO ON WHAT NEEDS TO BE LOOKED AT. | JEREMY | JEREMY | | B= | R | 3681001 |
MARK YOUNG CONSTRUCTION, INC. | BSP | P | 04/24/2007 | TALKED TO ERIC THE SUPERINTENDENT ABOUT THE STRUCTURAL INTEGRITY OF THE WIND BREAKING WALL THAT IS ATTACHED TO THE LID OF THE MAIN PEDESTRIAN WALKWAY. IT IS ATTACHED WITH ONLY 3 LIGHT GAGE 4" METAL STUDS THAT ARE ALMOST COMPLETELY WORN THROUGH.THIS IS A DANGEROUS SITUATION WITH THE WIND BLOWING AS PEOPLE WILL BE HURT IF THERE IS A FAILURE. THE SUPERINTENDENT ASSURED ME THIS WILL BE FIXED | BERTW | BERTW | | BSP | P | 3447077 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 04/18/2007 | LINTEL IS OK @ PHARMACY WINDOW CUTOUT/SOFFIT DROPS INTERIOR OF STORE ARE NOW COMPLETED FOR INSPECTION PURPOSES/ENTRY FRAMING IS NOW COMPLETED/NEED ALL ENGINEERING REPORTS PER PREVIOUS NOTES | BERTW | BERTW | | BFR | P | 3447070 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 03/28/2007 | FRONT ENTRANCE FRAMING SOUTH PORTION OK/NEED ENGINEERING REPORT FOR STRUCTURAL STEEL WELDS/STILL NEED CENTER AND NORTH SECTIONS INSPECTED/STARBUCKS AND FIRST BANK FASCIA FRAMING @ EXTERIOR CANOPY OK | BERTW | BERTW | | BFR | P | 3447063 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 03/21/2007 | 2ND FLOOR MEZZANINE OFFICES FRAMING OK/SEE SHEET A1.5 | BERTW | BERTW | | BFR | P | 3447055 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 03/15/2007 | 1)NEED ENGINEERING FOR LINTEL DELETED @ PHARMACY PIC-UP PRESCRIPTION WINDOW CUTOUT 2)ENGINNERING ON FILE FOR DROP SOFFITTS 3)SHEET S5.0 DETAIL #20 SHEET A2.1 #2 PHARMACY CANOPY FRAMING EXTERIOR FRAMING OK SEE PLANS FOR AREAS INSPECTED | BERTW | BERTW | | BFR | P | 3447048 |
MARK YOUNG CONSTRUCTION, INC. | BFN | P | 03/12/2007 | LAST OF 2 HELICALS/NEED ENGINEERING REPORT FOR FINAL | BERTW | BERTW | | BFN | P | 3447040 |
MARK YOUNG CONSTRUCTION, INC. | BFN | P | 03/09/2007 | LOOKED AT HELICALS 5 DONE NEED 2 MORE AND ENGINEER REPORT | BERTW | BERTW | | BFN | P | 3447033 |
MARK YOUNG CONSTRUCTION, INC. | BFT | P | 03/08/2007 | HELICAL PIERS, NEED ENGINEERS INSTALLATION REPORT WHEN READY | TERRYB | TERRYB | | BFT | P | 3447025 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 03/01/2007 | SEE SHEET A1.11 FOR INTERIOR NON BEARING WALLS INSPECTED | BERTW | BERTW | | BFR | P | 3447017 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 02/13/2007 | DROP SOFFITS FRAMING SEE SHEET A1.10 FOR AREAS INSPECTED/INTERIOR WALL FRAMING SEE SHEET A1.4 FOR AREAS INSPECTED/NEED SOFFIT DETAIL PER PREVIOUS INSPECTORS COMMENTS | BERTW | BERTW | | BFR | P | 3447008 |
MARK YOUNG CONSTRUCTION, INC. | BFR | R | 02/02/2007 | NEED DETAIL FOR SOFFET ATTACHMENT TO ROOF DECK AT REAR OF STORE | DANF | DANF | | BFR | R | 3447000 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 01/30/2007 | DROP SOFFITS @ BAKERY SEE PLANS FOR AREA INSPECTED SHEET A1.11 | BERTW | BERTW | | BFR | P | 3446992 |
MARK YOUNG CONSTRUCTION, INC. | BFR | P | 01/24/2007 | SEE PLANS SHEET A1.3 AND A1.4 FOR AREAS INSPECTED,WALLS OK | BERTW | BERTW | | BFR | P | 3446984 |
WAYNE'S ELECTRIC INC | E= | C | 07/24/2007 | SCOPE OF WORK COMPLETE , LIGHTING CHANGE AT A LATER DATE | BRET | BRET | | E= | C | 3446952 |
WAYNE'S ELECTRIC INC | E= | T | 06/14/2007 | PAID (REC#761689) TRIP FEE TOO MANY TRIPS.ORIGNAL SCOPE OF WORK COMPLETE CONTRACTOR IN THE PROCESS OF DRAWING PLANS FOR LIGHTING CHANGES WHEN FINISHED THEY WILL SUBMITT THEM FOR REVIEW | BRET | BRET | | E= | T | 3446944 |
WAYNE'S ELECTRIC INC | ER | T | 06/12/2007 | PAID (REC#755620): TRIP FEE FOR TOO MANY INSPECTIONS. PARTIAL FINAL FRONT OF STORE. ALL KITCHEN AREA 120V 15 AND 20 AMP RECEPTACLES NEED GFCI PROTECTION THIS INCLUDES EXISTING AS WELL AS NEW AS PER GENERAL NOTES ON PLANS. | BRET | BRET | | ER | T | 3446937 |
WAYNE'S ELECTRIC INC | ER | P | 05/21/2007 | BATHROOM ,FRONT VESTIBLE CEILINGS AND COOLERS OK INSTALL BREAKER LOCKS FOR COOLER UNITS | BRET | BRET | | ER | P | 3446930 |
WAYNE'S ELECTRIC INC | E= | R | 05/18/2007 | NEED TO TRIP FEE FROM NOW ON TILL LAST INSPECTION | TERRY | TERRY | | E= | R | 3446921 |
WAYNE'S ELECTRIC INC | ER | P | 05/14/2007 | SEE ORANGE CARD | MIKEC | MIKEC | | ER | P | 3446913 |
WAYNE'S ELECTRIC INC | ER | P | 04/20/2007 | FRONT ENTRY , TRANSFORMERS TBS45 AND TD75 | BRET | BRET | | ER | P | 3446906 |
WAYNE'S ELECTRIC INC | ER | P | 03/28/2007 | CEILINGS PHOTO/VIDEO SEE PLANS, FRONT SOFFITTS ABOVE STARBUCKS SIGN , FIRST BANK AND SOUTH ENTRY WALL | BRET | BRET | | ER | P | 3446897 |
WAYNE'S ELECTRIC INC | ER | P | 03/21/2007 | 2ND FLOOR OFFICE WALLS , FRONT SOUTH SOFFIT AND RTU #1 AND #2 OK | BRET | BRET | | ER | P | 3446890 |
WAYNE'S ELECTRIC INC | ER | P | 03/15/2007 | 2 OUTSIDE OUTLETS-PHOTO DARK RM. SWITCH-RTU TRANSFORMER APPEARS TO BE CORRECT BUT NEED ON LINE TO CORRESPOND. | RED | RED | | ER | P | 3446882 |
WAYNE'S ELECTRIC INC | ER | P | 03/06/2007 | FLORAL CEILING OK | BRET | BRET | | ER | P | 3446874 |
WAYNE'S ELECTRIC INC | ER | P | 03/01/2007 | SINK WALL IN FLORAL AND OFFICE SWITCH | BRET | BRET | | ER | P | 3446867 |
WAYNE'S ELECTRIC INC | ER | P | 02/21/2007 | CUSTOMER SERVICE AND BAKERY CEILING OK | BRET | BRET | | ER | P | 3446858 |
WAYNE'S ELECTRIC INC | ER | P | 02/16/2007 | OUTLETS CUSTOMER SERVICE COUNTERS | THOMAS | THOMAS | | ER | P | 3446847 |
WAYNE'S ELECTRIC INC | ER | T | 02/16/2007 | PAID (REC#737432): CIELING INSPECTION FRONT OF STORE ; PROPERLY SUPPORT MC--FINISH INSTALLING CONDUIT --SECURE 2X4 FIXTURES TO GRID---REMOVE OLD CONDUIT OR SUPPORT OFF CIELING---DATA CABLES LAYING ON CIELING-====CILING AT BACK OF STORE--CIELING WIRES NOT IDENTIFIED PER BRET | THOMAS | THOMAS | | ER | T | 3446831 |
WAYNE'S ELECTRIC INC | ER | R | 02/15/2007 | NO ELECTRICIAN --NO POINT OF CONTACT #---NO GENERAL CONTRACTOR----TOO MANY AREAS POSSIBLE TO INSPECT | THOMAS | THOMAS | | ER | R | 3446823 |
WAYNE'S ELECTRIC INC | ER | P | 02/13/2007 | SECURITY WALLS, BAKERY CEILING OK TO COVER BUT LEAVE TILE OUT ON ONE SDE OF FIXTURE. SECURE LOW VOLT WIRING | BRET | BRET | | ER | P | 3446812 |
WAYNE'S ELECTRIC INC | E= | P | 02/09/2007 | PHARMACY COMPLETE | THOMAS | THOMAS | | E= | P | 3446804 |
WAYNE'S ELECTRIC INC | ER | P | 02/02/2007 | PHARMACY CEILING OK CONTRACTOR TO IDENTIFY FIXTURE SUPPORT WIRES. | BRET | BRET | | ER | P | 3446797 |
WAYNE'S ELECTRIC INC | ER | P | 01/23/2007 | PHARMACY WALLS AND JANITOR CLOSET WALL OK | BRET | BRET | | ER | P | 3446789 |
ALWAYS PLUMBING & HEATING INC | H= | C | 04/18/2008 | | JON | JON | | H= | C | 3446976 |
AMERICAN MECHANICAL SERVICES | H= | C | 04/18/2008 | RECIEVED BALANCE REPORT | JON | JON | | H= | C | 3447292 |
ALWAYS PLUMBING & HEATING INC | H= | P | 04/17/2008 | SEE GAS NOTES. | JON | JON | | H= | P | 3446968 |
ALWAYS PLUMBING & HEATING INC | HI | C | 04/17/2008 | NEED CONDENSATE FROM AIR HANDLER AND BOILERS TO HAVE LISTING TAGS FOR MODEL NUMBERS, BTU'S AND LISTING. DOUBLE CHECK NEW OVEN FOR FUEL SOURCE. | JON | JON | | HI | C | 3446960 |
AMERICAN MECHANICAL SERVICES | H= | P | 12/07/2007 | NEED GAS PERMITS AND PROPER INSPECTIONS. NEED INSTRUCTIONS FOR NEW WATER HEATERS TO ENSURE CELL CORE IS ACCEPTABLE VENT MATERIAL. AIR BALANCE COMPANY TO PROVIDE THEIR CERTIFICATION DOCUMENTS. REST OK | JON | JON | | H= | P | 3447285 |
HUSSMANN CORPORATION | H= | C | 12/03/2007 | REFRIGERATION CONTRACTOR. ALL FLOOR DRAINS PARTIALLY EXPOSED AND CENTER RACKS HAVE HUB DRAINS IN TUNNEL. | ERIC | ERIC | | H= | C | 3447192 |
AMERICAN MECHANICAL SERVICES | H= | R | 11/21/2007 | CANCELLED BY CONTRACTOR | JON | JON | | H= | R | 3447281 |
HUSSMANN CORPORATION | H= | R | 11/15/2007 | REJECT NEED CALL AHEAD AND APPROVED PLANS ON SITE PER LAST INSPECTION NOTES FOR THIS CONTRACTOR., | JON | JON | | H= | R | 3447182 |
AMERICAN MECHANICAL SERVICES | H= | P | 06/07/2007 | NEED PERMIT CORRECTED, DID NOT SEE ANY NEW BOILERS OR WATER HEATRERS ON SCHEDULES. NEED VERIFICATION OF 800 PPM SENSOR INSTALLED PER PLANS AT RTU 1. NEED SMOKE SHUT DOWN VERIFIED AT BOTH UNITS. WILL WALK ROOF NEXT INSPECTION. BALANCE REPORT BEFORE FINAL. NEED TO ADDRESS WATER HEATERS. | JON | JON | | H= | P | 3447276 |
HUSSMANN CORPORATION | HRP | P | 04/10/2007 | TIE IN IN CAVE OK | DOUGR | DOUGR | | HRP | P | 3447174 |
AMERICAN MECHANICAL SERVICES | HD | P | 03/26/2007 | ABOVE CEILING NORTH WEST CORNER OF STORE | DOUGR | DOUGR | | HD | P | 3447268 |
AMERICAN MECHANICAL SERVICES | HD | P | 03/21/2007 | SUPPLY DUCT & EXHAUST DUCT & FAN OVER PHOTO LAB SINK ROOM OK | DOUGR | DOUGR | | HD | P | 3447260 |
AMERICAN MECHANICAL SERVICES | HD | P | 03/16/2007 | DROPS & CONNECTIONS FROM ROOF TOPS OK, NEED TO SEE RETURN DUCT DROPS TO CEILING FOR RTU 2, ALSO STILL HAVE DUCTS TO RUN ON NORTH END OF STORE - THERE ARE SOME FIREDAMPER QUESTIONS THAT INSPECTOR COVERED WITH ERIC THE SUPERINTENDENT & HE WILL GET CLARIFICATION FROM THE ENGINEER - SEE NOTES D,G, & H ON SCHEDULE OF DIFUSERS | DOUGR | DOUGR | | HD | P | 3447253 |
HUSSMANN CORPORATION | HRP | P | 03/05/2007 | OK TO CHARGE LINES, STILL NEED TO SEE CONNECTIONS IN TUNNEL, BY FINAL NEED REFRIGERATION DRAWING APPROVED & SPLICED INTO PLANS - CURRENTLY PLANS SHOW NO REFRIGERATION | DOUGR | DOUGR | | HRP | P | 3447166 |
AMERICAN MECHANICAL SERVICES | HD | P | 03/05/2007 | SUPPLIES ABOVE FLORAL OK | DOUGR | DOUGR | | HD | P | 3447247 |
AMERICAN MECHANICAL SERVICES | HD | P | 02/26/2007 | ABOVE CEILING FROM ENTRANCE & TOWARD THE SOUTH OVER REGISTERS OK | DOUGR | DOUGR | | HD | P | 3447239 |
AMERICAN MECHANICAL SERVICES | HD | P | 02/21/2007 | OK TO COVER CEILING IN RAISED AREA AT VERY FRONT OF STORE - STILL NEED TO SEE DUCTS COMPLETED & SEALED OVER CASHIER AREA, IN MAIN PART OF STORE OK TO COVER ALL EXCEPT DROPS FROM ROOFTOPS, OK TO COVER DAIRY AREA | DOUGR | DOUGR | | HD | P | 3447232 |
AMERICAN MECHANICAL SERVICES | HD | P | 02/09/2007 | OK TO COVER CEILING EXCEPT: WHERE MAIN TRUNK LINES RUN FRO PHARMACY & BAKERY TO NEW RTUS THAT ARE NOT IN YET, DAIRY AREA, CASHIER AREA | DOUGR | DOUGR | | HD | P | 3447225 |
AMERICAN MECHANICAL SERVICES | HD | P | 02/01/2007 | DUCT IN PHARMACY COMPLETE & OK TO DROP LID - STILL NEEDS TO RUN THRU STORE TO NEW RTU, FIRE WRAP IN BAKERY COMPLETE | DOUGR | DOUGR | | HD | P | 3447218 |
AMERICAN MECHANICAL SERVICES | HD | P | 01/31/2007 | GREASE DUCT ON BREAD OVENS OK TO FINISH WRAP, WILL NEED FIRE WRAP ON TOP OF HOOD ALSO AS THE CEILING STOPS AT EDGE OF HOOD | DOUGR | DOUGR | | HD | P | 3447212 |
AMERICAN MECHANICAL SERVICES | HD | P | 01/29/2007 | TOP 12' ON TWO GREASE DUCTS, OK TO WRAP AND DROP THROUGH ROOF. WILL INSPECT FROM THERE TO TOP OF HOOD AND THEN WRAP BOTTOM. | LYNNS | LYNNS | | HD | P | 3447205 |
AMERICAN MECHANICAL SERVICES | HD | P | 01/25/2007 | FOR HVAC CONTACT MARK AT 303-961-2965 PHARMACY... 26 X 18 AND 16 X 16 SUPPLY DUCT AND 8- HEAT RUNS READY FOR WRAP. | JON | JON | | HD | P | 3447197 |
VITTETOE PLUMBING CO., INC. | P= | C | 11/08/2007 | | MARTY | MARTY | | P= | C | 3447155 |
VITTETOE PLUMBING CO., INC. | PTO | R | 06/19/2007 | THIS WAS TO BE GREASE TRAP INSPECTION,WASTWATER. | MARTY | MARTY | | PTO | R | 3447148 |
VITTETOE PLUMBING CO., INC. | PB | C | 04/18/2007 | | MARTY | MARTY | | PB | C | 3447140 |
VITTETOE PLUMBING CO., INC. | PB | P | 04/11/2007 | 5- DRAINS IN PRODUCE DEPT. COMPLETE | LEE | LEE | | PB | P | 3447132 |
VITTETOE PLUMBING CO., INC. | PB | P | 03/12/2007 | STARBUCKS | MARTY | MARTY | | PB | P | 3447124 |
VITTETOE PLUMBING CO., INC. | PB | P | 02/27/2007 | FLORAL SIDE,FLOOR SINKS TESTED UNDER FLOOR AND THRU ROOF. | MARTY | MARTY | | PB | P | 3447116 |
VITTETOE PLUMBING CO., INC. | PTO | P | 01/23/2007 | PHARMACY,NORTH SIDE MOP SINK AND FLOOR DRAIN. | MARTY | MARTY | | PTO | P | 3447108 |
VITTETOE PLUMBING CO., INC. | PB | P | 01/23/2007 | PHARMACY,NORTH SIDE MOP SINK. | MARTY | MARTY | | PB | P | 3447101 |