BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 01/20/2008 | Temp CO: EXTERIOR OF BUILDING ONLY INSPECTED THIS DATE: MISSING HANDRAIL AT NORTH WEST STAIR TO PARKING. | JAN | JAN | | B= | P | 3522295 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | C | 01/17/2008 | | LEEG | LEEG | | B= | C | 3522770 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 01/07/2008 | HANDRAIL OKAY. NEED OTHER INSPECTIONS / NEED TEMPERED GLASS IN WINDOWS PER PREVIOUS INSPECTION. | LEEG | LEEG | | B= | P | 3522765 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 12/19/2007 | EXTERIOR OF BUILDING ONLY INSPECTED THIS DATE: MISSING HANDRAIL AT NORTH WEST STAIR TO PARKING. | LEEG | LEEG | | B= | P | 3522763 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 12/18/2007 | NEED ALL OTHER INSPECTIONS / SEE PREVIOUS INSPECTION NOTES / CLEAN SNOW AND ICE OFF WALKS, STEPS AND RAMPS FOR FINAL. | LEEG | LEEG | | B= | P | 3522760 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 12/17/2007 | NEED TEMPERED GLASS IN WINDOW AT BOTTOM OF INTERIOR STAIRS UNITS 203/206/303/306, UNITS 103/104/106/204/205 NEED ELECRTICAL FINALS ON THIS HALF. | CHRISM | CHRISM | | B= | P | 3522756 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 12/12/2007 | INTERIOR ONLY OF UNITS FOLLOWING: UNITS 107 & 207 OKAY. UNITS 101, 102, 108, 208, 302, 307 MISSING PATIO DOOR LOCKS / UNITS 108, 201, 202, 208 FIRE CAULK OPENIGS MECHANICAL ROOM CEILINGS / UNIT 206 MISSING WEATHERSTRIPPING PATIO DOOR. NEED ALL OTHER FINALS ALL UNITS PLUS EXTERIORS AND BREEZEWAYS INSPECTED. | LEEG | LEEG | | B= | P | 3522754 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | P | 12/06/2007 | All balcony frming complete - need final inspection of decks at time of unit inspection. | LEEG | LEEG | | B= | P | 3522749 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/30/2007 | EAST HALF OF BUILDING BALCONY FRAME: UNITS 107 & 207 REPLACE NAILS IN HANGERS WITH CORROSION RESISTANT NAILS. | LEEG | LEEG | | BSP | P | 3522745 |
BLUE SPRUCE CONSTRUCTORS, LLC | B= | R | 11/29/2007 | NEED BUILDING ADDRESS NUMBERS / NEED UNIT NUMBERS / NEED ALL OTHER INSPECTIONS / NOT READY FOR FINAL INSPECTION. | LEEG | LEEG | | B= | R | 3522741 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/08/2007 | FIRE CAULKING INSIDE UNITS AT COMMON WALLS EAST HALF OF BUILDING FIRST, SECOND AND THIRD FLOORS. | LEEG | LEEG | | BSP | P | 3522736 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/07/2007 | FIRE CAULKING AT PLUMBING PENETRATIONS COMMON WALLS 10 UNITS 103 THRU 303 WEST HALF OF BUILDING. | LEEG | LEEG | | BSP | P | 3522730 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 11/07/2007 | INTERIOR DRYWALL SHEER NAILING COMPLETE. | LEEG | LEEG | | BSP | P | 3522725 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/26/2007 | INTERIOR DRYWALL SHEAR NAILING OKAY UNITS 104, 105 & 106. PERMIT NOT AVAILABLE TO SIGN.'\
| LEEG | LEEG | | BSP | P | 3522719 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/25/2007 | UNITS 204 & 205 INTERIOR DRYWALL SHEAR NAILING OKAY. | LEEG | LEEG | | BSP | P | 3522714 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/24/2007 | DDRYWALL SHEAR 206 & 203 OK | CHRISM | CHRISM | | BSP | P | 3522708 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/22/2007 | INTERIOR SHEAR FOR UNITS 303 +306 OKAY | TODDS | TODDS | | BSP | P | 3522703 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/19/2007 | DRYWALL SHEAR OK UNIIT 103 | CHRISM | CHRISM | | BSP | P | 3522697 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | C | 10/18/2007 | | LEEG | LEEG | | BIN | C | 3522692 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | C | 10/18/2007 | | LEEG | LEEG | | BFR | C | 3522688 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 10/17/2007 | R-C CHANNEL, INTERIOR SHEAR OKAY UNITS 104, 105, 204 & 205 OKAY. | LEEG | LEEG | | BFR | P | 3522677 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 10/17/2007 | UNITS 104, 105, 204 & 205 OKAY. | LEEG | LEEG | | BIN | P | 3522682 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 10/16/2007 | insulation ok in units 103, 106, 203, 206, 303, 306. | RONG | RONG | | BIN | P | 3522671 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 10/16/2007 | RC Channel and shear ok in units 103, 106, 203, 206, 303, 306. | RONG | RONG | | BFR | P | 3522666 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/12/2007 | INTERIOR DRYWALL SHEAR NAILING OKAY UNIT 302. | LEEG | LEEG | | BSP | P | 3522661 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/11/2007 | DRYWALL NAILING INTERIOR SHEAR WALLS OKAY UNITS 107, 108, 201, 202, 207 & 208. | LEEG | LEEG | | BSP | P | 3522657 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 10/09/2007 | DRYWALL NAILING OKAY UNITS 101, 102 & 307. | LEEG | LEEG | | BSP | P | 3522651 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 10/09/2007 | FIRE CAULKING INSIDE WALLS UNITS 103, 104, 105, 106, 203, 204, 205, 206, 303 & 306 OKAY. | LEEG | LEEG | | BFR | P | 3522646 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 10/04/2007 | INSULATION OKAY AT DOUBLE WALLS BETWEEN UNITS. | LEEG | LEEG | | BIN | P | 3522640 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 10/03/2007 | R-C CHANNEL AND INSULATION OKAY UNITS 101, 102, 107, 108, 201, 202, 207, 208, 302 & 307. | LEEG | LEEG | | BIN | P | 3522635 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 10/03/2007 | UNITS 302 & 307 OKAY. B-VENT CLEARANCE OKAY UNIT 202. | LEEG | LEEG | | BFR | P | 3522628 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 10/02/2007 | UNITS 101, 102, 107, 108, 201, 207, 208 OKAY. UNIT 202 B-VENT CLEARANCE LESS THAN 1". | LEEG | LEEG | | BFR | P | 3522621 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 09/27/2007 | R-C CHANNEL CEILINGS OF THIRD FLOOR BREEZEWAYS OKAY. PERMIT NOT AVAILABLE TO SIGN. | LEEG | LEEG | | BFR | P | 3522614 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 09/26/2007 | ONE HOUR PENETRATION TREATMENT OKAY EAST HALF BUILDING UNITS 101, 102, 107, 108 201, 202, 207, 208, 302 & 307 OKAY | LEEG | LEEG | | BFR | P | 3522606 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 09/25/2007 | UNITS 101, 108, 201 & 208: ABOVE CEILING AND INSIDE WALL FIRE CAULKING: TOUCH UP AROUND OPENINGS AND RE-CALL INSPECTION. | LEEG | LEEG | | BFR | R | 3522599 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 09/24/2007 | R-C CHANNEL AT COVERED DECK CEILINGS TOP MOST LEVELS NORTH AND SOUTH ELEVATIONS OKAY. | LEEG | LEEG | | BSP | P | 3522591 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 09/24/2007 | UNITS 104, 105, 204 & 205: OKAY AFTER ALL OTHER INSPECTINS. UNIT 204 MISSING LAGS IN 4 PLY MICROLAM BEAM MAIN FLOOR. | LEEG | LEEG | | BFR | P | 3522583 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 09/11/2007 | UNITS 204 & 205 TRUSSES, POSTS, BEAMS & WALLS PRIOR TO ALL OTHER TRADES. CLIP TOP PLATES AT CORNERS NOT LAPPED / MISSING LATERAL BRACES / SHIM MICROLAM BEAM BEARING OVER ENTRY DOOR / DOUBLE STUDS UNDER ENDS OF HIP MASTER TRUSS BG / MISSING TRUSS HANGERS AT HIP TRUSSES EJ1 & CJ1 / MISSING LEDGER LAGS / MISSING LAGS IN 4 PLY MICROLAM BEAMS. | LEEG | LEEG | | BFR | R | 3522575 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 09/05/2007 | UNITS 103, 203, 303, 106, 206 & 306 FOR STRUCTURAL COMPONENETS PRIOR TO INSTALLATION OF ELECTRICAL, PLUMBING & MECHANICAL SYSTEMS. TRUSSES, WALLS, FLOORS AND BEAMS OKAY. NEED RE-INSPECTION AFTER SYSTEMS INSTALLED. | LEEG | LEEG | | BFR | P | 3522569 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/30/2007 | UNITS 107, 207 & 307 ONLY, POINT LOADS AND WALL FRAMING OKAY / NEED ALL OTHER INSEPECTIONS. | LEEG | LEEG | | BFR | P | 3522563 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/29/2007 | UNITS 102, 203 & 302 WALLS OKAY, POINT LOADS OKAY, NEED ALL OTHER INSPECTIONS. | LEEG | LEEG | | BFR | P | 3522557 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 08/28/2007 | UNITS 201 207: P3 AND P4 POSTS / FHA STRAP PLATE BREAKS / TRUSS LEDGER ATTACHEMENT / BOLT PATTERN FOR 4 MEMBER MICROLAM / EXTEND ALL POINT LOADS TO FOUNDATION. | LEEG | LEEG | | BFR | R | 3522548 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/27/2007 | ROOF TRUSSES ONLY UNITS 201, 202, 207 & 208 OKAY. | LEEG | LEEG | | BFR | P | 3522538 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/27/2007 | EXTERIOR SHEAR 2ND AND 3RD FLOORS OKAY. | LEEG | LEEG | | BFR | P | 3522531 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | R | 08/24/2007 | ROOF TRUSSES ONLY UNITS 201, 202, 207 & 208. MISSING LATERAL BRACES B2 & C8 / ROLL BLOCK B TRUSSES. PERMIT NOT AVAILABLE TO SIGN. | LEEG | LEEG | | BFR | R | 3522523 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 08/15/2007 | PRE-INSULATION BEHIND TUBS AT SHEAR WALLS UNITS 201 THRU 208 AND 302, 303, 306 & 307 OKAY. | LEEG | LEEG | | BIN | P | 3522515 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/15/2007 | INTERIOR TRUSS BEARING PARTITIONS THIRD FLOOR LOFT UNITS 302, 303, 306 & 307 OKAY. 5/8" DRYWALL BEHIND SHEATHING OKAY. | LEEG | LEEG | | BFR | P | 3522508 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 08/14/2007 | PRE-INSULATION BEHIND FIREPLACES UNITS 202, 203, 206 & 207 OKAY. PRE-INSULATION AND FIRE BLOCKING BEHIND STAIRS AT THIRD FLOOR LOFTS UNITS 302, 303, 306 & 307 OKAY. | LEEG | LEEG | | BIN | P | 3522499 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/09/2007 | 3RD FLOOR EXTERIOR SHEAR AT BREEZEWAYS ONLY OKAY. PLYWOOD SHEAR TO BE COVERED WITH 5/8" EXTERIOR DRYWALL. | LEEG | LEEG | | BFR | P | 3522492 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/03/2007 | FIRST FLOOR ANCHOR BOLTS EAST END ONLY OKAY. | LEEG | LEEG | | BFR | P | 3522484 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/02/2007 | FLOOR TRUSSES SUPPORTING UNITS 203, 204, 205 & 206 OKAY. | LEEG | LEEG | | BFR | P | 3522475 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/01/2007 | PRE-SHEAR BEHIND MECHANICAL UNITS AND PLANT SHELVES ONLY IN UNITS 205 AND 208 OKAY. | LEEG | LEEG | | BFR | P | 3522468 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 08/01/2007 | 2ND FLOOR - FLOOR TRUSSES ONLY, UNITS 201, 202, 207 & 208 OKAY. INSPECTED TRUSSES ONLY PRIOR TO INSTALLATION OF MECHANICAL EQUIPMENT AND DUCTS. | LEEG | LEEG | | BFR | P | 3522460 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 07/27/2007 | SECOND FLOOR INTERIOR SHEAR WALL BEHIND BATH TUBS AND POT SHELVES OKAY. | LEEG | LEEG | | BFR | P | 3522451 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 07/27/2007 | FIRST FLOOR EXTERIOR SHEAR NAILING OKAY. | LEEG | LEEG | | BFR | P | 3522445 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 07/26/2007 | PRE-INSULATE: STAIR WALLS TO LOFT BEDROOMS UNITS 201, 204, 205 & 208 OKAY. RIM JOIST UNITS 201, 204, 205, 208, 202, 207, 203 & 206 OKAY. | LEEG | LEEG | | BIN | P | 3522437 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 07/26/2007 | SECOND FLOOR BALCONY BEAMS AND POSTS OKAY. | LEEG | LEEG | | BFR | P | 3522428 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 07/26/2007 | SECOND FLOOR BREEZEWAY EXTERIOR SHEAR OKAY. | LEEG | LEEG | | BFR | P | 3522421 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 07/19/2007 | FIREPLACE EXTERIOR WALLS FOR PREROCK OK 101 TO 108 OK ALL BUT 102 | CHRISM | CHRISM | | BIN | P | 3522412 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 07/19/2007 | RC CHANNEL FIREPLACES 101 TO 108 OK ALL BUT 102 | CHRISM | CHRISM | | BSP | P | 3522406 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 07/19/2007 | SHEAR WALLS FIRST FLOOR EAST AND WEST BREEZEWAYS OK | CHRISM | CHRISM | | BFR | P | 3522398 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 07/17/2007 | PRE SHEER OK FOR TUB WALLS, AT PLANT LEDGES OK FOR UNITS 105, 106, 107, 108 | TIMS | TIMS | | BSP | P | 3522389 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 07/17/2007 | PRE-ROCK AT TUBS , PLANT LEDGES AND BREEZE WAY RIMS OK FOR UNITS 105 106 107 108 | TIMS | TIMS | | BSP | P | 3522381 |
BLUE SPRUCE CONSTRUCTORS, LLC | BIN | P | 07/12/2007 | PRE-INSULATION AT BATH TUB WALLS, 1ST FLOOR BREEZEWAY LADDER TRUSSES OK | TODDS | TODDS | | BIN | P | 3522373 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | P | 07/06/2007 | OK 1ST FLOOR LADDER TRUSS SHEAR NAILING AT 24" RIPPER | FRANK | FRANK | | BSP | P | 3522365 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFR | P | 07/03/2007 | MAIN FLOOR EXTERIOR BALCONY BEAMS AND POSTS OKAY. | LEEG | LEEG | | BFR | P | 3522358 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFI | C | 06/22/2007 | | LEEG | LEEG | | BFI | C | 3522350 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFN | C | 06/22/2007 | NEED CABLE PULL REPORT. EUFER GROUND INSTALLED WEST END OF BUILDING. | LEEG | LEEG | | BFN | C | 3522342 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFN | P | 06/15/2007 | EAST HALF SLAB OKAY. NEED TENSION REPORT | LEEG | LEEG | | BFN | P | 3522334 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFI | P | 06/15/2007 | EAST HALF BUILDING OKAY. | LEEG | LEEG | | BFI | P | 3522326 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | T | 06/07/2007 | PAID (REC#754749)ADDITIONAL PLAN REVIEW TIME: $50.000 From: RICH revised b12 to b3 changes at mster bath | RICH | RICH | | BSP | T | 3522311 |
BLUE SPRUCE CONSTRUCTORS, LLC | BSP | T | 06/07/2007 | PAID (REC#754751)ADDITIONAL PLAN REVIEW TIME: $50.000 From: RUSSELL Revised mechanical, added toilet room | RUSSELL | RUSSELL | | BSP | T | 3522319 |
BLUE SPRUCE CONSTRUCTORS, LLC | BFT | C | 05/08/2007 | OPEN HOLE LETTER WITH INSPECTOR. NEED CABLE PULL REPORT WITH SLAB CABLE REPORT. | LEEG | LEEG | | BFT | C | 3522304 |
BRILLIANT ELECTRIC, LLC | E= | C | 12/19/2007 | all units good----204--107 have ac installed-----rest are prewired | THOMAS | THOMAS | | E= | C | 3522852 |
BRILLIANT ELECTRIC, LLC | E= | R | 12/18/2007 | 3OUTLETS IN LIVING ROOM & PORCH GFCI MISSWIRED----PLATE MISSING UNDER KITCHEN SINK---ENTRY LIGHT NOT WORKING | THOMAS | THOMAS | | E= | R | 3522845 |
BRILLIANT ELECTRIC, LLC | E= | P | 12/18/2007 | UNITS 106==203==206 COMPLETE=== | THOMAS | THOMAS | | E= | P | 3522841 |
BRILLIANT ELECTRIC, LLC | E= | P | 12/17/2007 | units 101==104==105==107==108==201==202==204==205==208==303==306---c0mplete | THOMAS | THOMAS | | E= | P | 3522840 |
BRILLIANT ELECTRIC, LLC | E= | R | 12/13/2007 | units 104==105==204==205 good except all need outlets for water heater power vent===also units 101==108==201==208 where approved but need power vent outlets | THOMAS | THOMAS | | E= | R | 3522837 |
BRILLIANT ELECTRIC, LLC | E= | P | 12/11/2007 | UNIT'S 101; 102; 108; AND BREEZWAY OK; UNIT 107 FAILED BECAUSE AC INSTALLED BUT NOT WIRED; OTHER THREE UNITS HAVE AC PRE ROUGHED ONLY | JOSEPH | JOSEPH | | E= | P | 3522834 |
BRILLIANT ELECTRIC, LLC | E= | P | 12/10/2007 | UNIT 302 AND 307 AND THIRD FLOOR EAST SIDE BREEZEWAY | JOSEPH | JOSEPH | | E= | P | 3522832 |
BRILLIANT ELECTRIC, LLC | E= | P | 12/07/2007 | UNITS 210--202--207--208 COMPLETE | THOMAS | THOMAS | | E= | P | 3522830 |
BRILLIANT ELECTRIC, LLC | EP | P | 10/24/2007 | FAULT CURRENT FOR HOUSE PANEL ---GOOD | THOMAS | THOMAS | | EP | P | 3522827 |
BRILLIANT ELECTRIC, LLC | EP | P | 10/22/2007 | ON FINAL HOUSE PANEL MUST HAVE 22,000 AIC BREAKERS OR FAULT CURRENTS SHOWING HOUSE PANEL | THOMAS | THOMAS | | EP | P | 3522824 |
BRILLIANT ELECTRIC, LLC | ES | C | 10/22/2007 | COMMERCIAL SERVICE: 1200 AMP 3 WIRE 120/240 VOLT CONDOMINIUM SERVICE BY BRILLIANT ELECTRIC, LLC-----NEED ENERGIZED & METERS FOR UNITS 101--102--103--104--105--106--107--108--201--202--203--204--205--206--207--208--302--303--306--307--HOUSE | THOMAS | THOMAS | | ES | C | 3522823 |
BRILLIANT ELECTRIC, LLC | ES | R | 10/18/2007 | NEED FAULT CURRENT CALCULATIONS | THOMAS | THOMAS | | ES | R | 3522820 |
BRILLIANT ELECTRIC, LLC | ES | T | 10/08/2007 | PAID (REC#775541)APPROVED PRINTS NOT ON SITE | THOMAS | THOMAS | | ES | T | 3522818 |
BRILLIANT ELECTRIC, LLC | ER | C | 10/05/2007 | CLOSET 105 | THOMAS | THOMAS | | ER | C | 3522816 |
BRILLIANT ELECTRIC, LLC | ER | P | 09/26/2007 | 104-105-204-205 EXCLUDING 105 BEDROOM CLOSET [SE CABLE NOT COMPLETE | THOMAS | THOMAS | | ER | P | 3522811 |
BRILLIANT ELECTRIC, LLC | ER | P | 09/24/2007 | units 106, 206, 203, 306, and 303 ok; south wall packs rough ok | MATTHEW | MATTHEW | | ER | P | 3522810 |
BRILLIANT ELECTRIC, LLC | ER | P | 09/21/2007 | 101--102--103---WEST BREEZEWAYS | THOMAS | THOMAS | | ER | P | 3522805 |
BRILLIANT ELECTRIC, LLC | ER | P | 09/20/2007 | UNITS 107--108--202--207--302---307 GOOD-----EAST BREEZEWAYS & NORTH WALLPACKS | THOMAS | THOMAS | | ER | P | 3522800 |
BRILLIANT ELECTRIC, LLC | ER | P | 09/19/2007 | UNITS 101--102---108---201---208 COMPLETE EXCLUDING WALL LEFT OF FIREPLACE IN UNIT 108--12/2 WITHOUT BOX | THOMAS | THOMAS | | ER | P | 3522796 |
BLUE FLAME GAS COMPANY, INC. | H= | C | 12/14/2007 | GAS AND FIREPLACE FINAL. | LYNNS | LYNNS | | H= | C | 3522163 |
STEEL-T HEATING, INC. | H= | C | 12/14/2007 | HVAC FINAL FOR UNITS 103, 104, 105, 106, 203, 204, 205 206, 302 AND 306. AC INSTALLED IN UNITS 107 AND 204. | LYNNS | LYNNS | | H= | C | 3522287 |
BLUE FLAME GAS COMPANY, INC. | H= | P | 12/07/2007 | GAS AND FIREPLACE FINALS IN UNITS: 101, 102, 107, 108, 201, 202, 207, 208, 302 AND 307. | LYNNS | LYNNS | | H= | P | 3522155 |
STEEL-T HEATING, INC. | H= | P | 12/07/2007 | HVAC FINALS IN UNITS: 101, 102, 107, 108, 201, 202, 2 07, 208, 302 AND 307. | LYNNS | LYNNS | | H= | P | 3522280 |
BLUE FLAME GAS COMPANY, INC. | H= | P | 10/30/2007 | PARTIAL GAS FINAL FOR GAS METERS. OK FOR METERS. | LYNNS | LYNNS | | H= | P | 3522147 |
BLUE FLAME GAS COMPANY, INC. | H= | P | 10/23/2007 | ALL UNITS MUST HAVE FLEX CONNECTORS INSTALLED TO EQUIPMENT OR GAS LINES PLUGGED/CAPPED IN MECHANICAL ROOM. | NANCY | NANCY | | H= | P | 3522140 |
BLUE FLAME GAS COMPANY, INC. | HV | C | 10/12/2007 | ALL FIREPLACE VENTS COMPLETE. | LYNNS | LYNNS | | HV | C | 3522131 |
BLUE FLAME GAS COMPANY, INC. | HV | P | 10/10/2007 | ALL FIREPLACE VENTS OK EXCEPT FOR UNITS 205 AND 303, VENTS TOO CLOSE TO WOOD. | LYNNS | LYNNS | | HV | P | 3522124 |
STEEL-T HEATING, INC. | HRP | C | 10/09/2007 | HRP COMPLETE. | LYNNS | LYNNS | | HRP | C | 3522272 |
STEEL-T HEATING, INC. | HD | C | 10/09/2007 | ROUGH DUCT COMPLETE. | LYNNS | LYNNS | | HD | C | 3522263 |
STEEL-T HEATING, INC. | HV | C | 10/09/2007 | FURNACE, WATER HEATER, BATH AND DRYER VENTS OK. | LYNNS | LYNNS | | HV | C | 3522257 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 10/05/2007 | 10- 10# TESTS AND DESIGN OK. | LYNNS | LYNNS | | HI | C | 3522117 |
STEEL-T HEATING, INC. | HV | P | 10/03/2007 | BATH FANS, DRYERS AND B-VENTS IN UNITS: 302, 307, 103, 104, 105, 106, 203, 204, 205 AND 206 OK. | LYNNS | LYNNS | | HV | P | 3522249 |
STEEL-T HEATING, INC. | HRP | P | 10/03/2007 | REFIGERATION PIPING IN UNITS: 302, 307, 103, 104, 105, 106, 203, 204, 205 AND 206 OK. | LYNNS | LYNNS | | HRP | P | 3522241 |
STEEL-T HEATING, INC. | HD | P | 10/03/2007 | ROUGH DUCT IN UNITS: 302, 307, 103, 104, 105, 106, 203, 204, 205 AND 206. | LYNNS | LYNNS | | HD | P | 3522234 |
STEEL-T HEATING, INC. | HRP | P | 10/02/2007 | CANCELLED BY CONTRACTOR. | LYNNS | LYNNS | | HRP | P | 3522226 |
STEEL-T HEATING, INC. | HV | P | 10/02/2007 | CANCELLED BY CONTRACTOR. | LYNNS | LYNNS | | HV | P | 3522217 |
STEEL-T HEATING, INC. | HD | P | 10/02/2007 | CANCELLED BY CONTRACTOR. | LYNNS | LYNNS | | HD | P | 3522210 |
BLUE FLAME GAS COMPANY, INC. | HI | P | 09/25/2007 | 10- 10# TESTS AND DESIGN OK ON EAST HALF OF BUILDING. | LYNNS | LYNNS | | HI | P | 3522108 |
STEEL-T HEATING, INC. | HD | P | 09/25/2007 | ROUGH DUCT IN UNITS 101, 102, 107, 108, 201, 202, 207 AND 208 OK. REFRIGERATION LINES OK. BATH ABD DRYER VENTS OK. STILL QUESTION B-VENT CHASES. | LYNNS | LYNNS | | HD | P | 3522202 |
STEEL-T HEATING, INC. | HD | P | 09/14/2007 | THIRD FLOOR MECHANICAL CLOSETS OK TO SHEET ROCK. | LYNNS | LYNNS | | HD | P | 3522194 |
STEEL-T HEATING, INC. | HRR | R | 09/12/2007 | NO ONE ON SITE FROM CONTRACTOR, DID NOT KNOW WHAT TO INSPECT. | LYNNS | LYNNS | | HRR | R | 3522187 |
STEEL-T HEATING, INC. | HD | P | 09/06/2007 | ROUGH DUCT FOR MECHANICAL ROOMS IN UNITS: 103, 203, 104, 204, 105, 205, 106 AND 206 OK. | LYNNS | LYNNS | | HD | P | 3522179 |
STEEL-T HEATING, INC. | HD | P | 09/05/2007 | PARTIAL ROUGH FOR MECHANCIAL ROOMS IN UNITS: 101, 201, 102, 202, 107, 207, 108 AND 208. OK TO SHEET ROCK. | LYNNS | LYNNS | | HD | P | 3522172 |
B & L PLUMBING, INC. | P= | C | 12/20/2007 | ALL UNITS | LYNNIE | LYNNIE | | P= | C | 3522100 |
B & L PLUMBING, INC. | P= | P | 12/19/2007 | 103/104/203/306 OK | JEFF | JEFF | | P= | P | 3522093 |
B & L PLUMBING, INC. | P= | P | 12/12/2007 | 101-102-107-108-202-207-208-307-105-106-303 | LYNNIE | LYNNIE | | P= | P | 3522084 |
B & L PLUMBING, INC. | PTO | C | 08/23/2007 | | JEFF | JEFF | | PTO | C | 3522077 |
B & L PLUMBING, INC. | PTO | P | 08/22/2007 | LEAKS ON VENTS AT 207 AND 307, COMPLETE NAIL PROTECTION AS NOTED BEFORE | JEFF | JEFF | | PTO | P | 3522069 |
B & L PLUMBING, INC. | PTO | P | 08/20/2007 | UNIT 101/108/201/208, COMPLETE NAIL PROTECTION BY NEXT INSPECTION | JEFF | JEFF | | PTO | P | 3522060 |
B & L PLUMBING, INC. | PTO | P | 08/15/2007 | 103/203/303/106/206/306 OK | JEFF | JEFF | | PTO | P | 3522052 |
B & L PLUMBING, INC. | PTO | P | 08/13/2007 | 104/105/204/205 OK PENDING REVISED PLANS | JEFF | JEFF | | PTO | P | 3522044 |
B & L PLUMBING, INC. | PB | C | 06/07/2007 | REVISED APPROVED PLANS BY PTO | JEFF | JEFF | | PB | C | 3522035 |
B & L PLUMBING, INC. | PB | R | 06/04/2007 | NO ACCESS TO APPROVED PLANS, NO ACCESS TO PERMIT, WORK DOES NOT RESEMBLE PLANS?.....REDO/RETEST | JEFF | JEFF | | PB | R | 3522028 |