THOMAS GENERAL CONTRACTORS, INC. | B= | C | 12/15/2010 | Per phone call from Mike Rogers | JAN | JAN | | B= | C | 4086257 |
THOMAS GENERAL CONTRACTORS, INC. | B= | R | 11/30/2010 | Problem not corrected - CSFD would not accept private inspection company letter (They want updated plans & a 2nd fire final inspection) | MIKE | MIKE | | B= | R | 4077855 |
THOMAS GENERAL CONTRACTORS, INC. | B= | P | 10/21/2010 | Additional Inspections Required: ENVIRONMENTAL HTG & AIR COND Mechanical Final Inspection is not Completed yet. Need mechanical final, Need signed smoke detector/rated door holdopen inspection letter -- Schedule a new Building Final when above items are complete. | MIKE | MIKE | | B= | P | 4059419 |
THOMAS GENERAL CONTRACTORS, INC. | BSP | T | 10/01/2010 | PAID (REC#940614) PLAN SPLICE FEE: $50 by: SHELBY for Electrical: two pages | SHELBY | SHELBY | | BSP | T | 4049529 |
THOMAS GENERAL CONTRACTORS, INC. | B= | P | 09/24/2010 | Temp CO: additonal Finals required ( Expires: 10/24/2010 12:00:00 AM) | JAN | JAN | | B= | P | 4045315 |
THOMAS GENERAL CONTRACTORS, INC. | B= | P | 09/24/2010 | Additional Inspections Required: External Agency Inspection Z= by ZONING is not Completed yet (Contact: ngadson@springsgov.com or 385-5982), ENVIRONMENTAL HTG & AIR COND Mechanical Final Inspection is not Completed yet, SIMMONS MECHANICAL Plumbing Final Inspection is not Completed yet. Need mechanical & plumbing finals, Complete all rated doors & hardware, Complete all HC restrooms -- Schedule a new Building Final when above items are complete. | MIKE | MIKE | | B= | P | 4045184 |
THOMAS GENERAL CONTRACTORS, INC. | BFR | C | 09/24/2010 | Received inspection report from Dwight Cooper(13176) indicating the window openings cut into the exterior bearing wall are ok as completed | MIKE | MIKE | | BFR | C | 4045181 |
THOMAS GENERAL CONTRACTORS, INC. | BLA | C | 09/24/2010 | Received stucco lath inspection report from John Davis(B-2263) | MIKE | MIKE | | BLA | C | 4045178 |
THOMAS GENERAL CONTRACTORS, INC. | B= | R | 09/23/2010 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: rdassero@springsgov.com or 385-7396), External Agency Inspection Z= by ZONING is not Completed yet (Contact: ngadson@springsgov.com or 385-5982), ENVIRONMENTAL HTG & AIR COND Mechanical Final Inspection is not Completed yet, SIMMONS MECHANICAL Plumbing Final Inspection is not Completed yet. Need fire/mechanical/plumbing finals, Need completed frame & lath inspections, Complete exterior stone at front entrance, Complete all rated doors & hardware, Complete all HC restrooms to code | MIKE | MIKE | | B= | R | 4044488 |
THOMAS GENERAL CONTRACTORS, INC. | BFR | P | 09/23/2010 | Need engineer inspection report for new windows cut into exterior bearing wall | MIKE | MIKE | | BFR | P | 4044484 |
THOMAS GENERAL CONTRACTORS, INC. | BSP | P | 09/20/2010 | Corridor walls complete | MIKE | MIKE | | BSP | P | 4041985 |
THOMAS GENERAL CONTRACTORS, INC. | BSP | R | 09/15/2010 | Corridor walls - Fire caulking not complete, Framing to structure not complete at Door #34 | MIKE | MIKE | | BSP | R | 4039732 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | BSP | T | 09/03/2010 | PAID (REC#933009) PLAN SPLICE FEE: $50 by: RUSSELL for Mechanical: splice of mechanical page, adding F?S dampers | RUSSELL | RUSSELL | | BSP | T | 4035006 |
THOMAS GENERAL CONTRACTORS, INC. | BSP | T | 09/02/2010 | PAID (REC#930229) PLAN SPLICE FEE: $50 by: JAY for Construction: corridor adjustments. | JAY | JAY | | BSP | T | 4034587 |
THOMAS GENERAL CONTRACTORS, INC. | BFR | P | 08/30/2010 | Knee wall front lobby ok, Need all rough inspections, Need to complete rated corridor walls, Need updated approved plans (wall modifications, Missing rated door at Rm #27, W1 wall designation at all corridor walls, Include structural plan for new windows cut into exterior bearing masonry wall) | MIKE | MIKE | | BFR | P | 4031858 |
THOMAS GENERAL CONTRACTORS, INC. | BFR | P | 08/20/2010 | WALLS OK/FIRE SAFEING @ TOP SLIP TRACK OK/DID NOT TAKE DETAIL FOR DELETION OF FIRE SAFING @ BOTTOM TRACK, SUPERINTENDENT SAID PREVIOUS INSPECTOR WANTS A WET STAMP LETTER/NEED PLANS TO MATCH NEW WALL LAYOUT | BERTW | BERTW | | BFR | P | 4027629 |
THOMAS GENERAL CONTRACTORS, INC. | BFR | P | 08/18/2010 | Interior partition walls marked on plans - Install fire safeing as specified on approved plan, Complete rated walls, Reviewed problems with supt & plan check | MIKE | MIKE | | BFR | P | 4026192 |
THOMAS GENERAL CONTRACTORS, INC. | BFR | R | 08/11/2010 | Partition walls for office #12,13,14,15,17,18 - Need fire safeing top & bottom track per approved plan, Approved plan does not match construction | MIKE | MIKE | | BFR | R | 4023295 |
Q-5 INC. | E= | C | 09/21/2010 | | BRET | BRET | | E= | C | 4042869 |
Q-5 INC. | ER | C | 09/16/2010 | | MATTHEW | MATTHEW | | ER | C | 4040645 |
Q-5 INC. | ER | P | 09/09/2010 | hard lids OK except evidence room | BRET | BRET | | ER | P | 4036906 |
Q-5 INC. | ER | P | 09/03/2010 | wall inspection for metal clad cable above sub panel by front door | JOSEPH | JOSEPH | | ER | P | 4034679 |
Q-5 INC. | ER | P | 08/30/2010 | waiting area half wall only. note: remove old lighting circuits and fixtures. | BRET | BRET | | ER | P | 4031805 |
Q-5 INC. | ER | P | 08/19/2010 | walls marked on plans | BRET | BRET | | ER | P | 4026692 |
Q-5 INC. | ER | P | 08/16/2010 | walls marked on plans | BRET | BRET | | ER | P | 4024710 |
Q-5 INC. | ER | P | 08/11/2010 | walls marked on plans | MATTHEW | MATTHEW | | ER | P | 4022740 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | C | 11/24/2010 | RECEIVED BALANCE REPORT. | LYNNS | LYNNS | | H= | C | 4076391 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | P | 11/23/2010 | PENDING BALANCE. | LYNNS | LYNNS | | H= | P | 4075592 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | P | 11/19/2010 | FIRE/SMOKE DAMPER FRAMING OK. | LYNNS | LYNNS | | H= | P | 4074172 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | P | 10/21/2010 | RTU1: INSTALL TWO FIRE/SMOKE DAMPERS ON 18X18 DUCT THAT SUPPLIES RATED CORRIDORS. RTU2: FILL GAPS ON TOP OF 12 INCH ROUND FIRE/SMOKE DAMPER. FILL GAPS ON TOP OF 12X10 FIRE/SMOKE DAMPER. CHECK ALL FIRE/SMOKE DAMPERS FOR PROPER OPENING SIZE AND THAT ANY GAPS ARE CLOSED WITH ANGLE. PROVIDE TEST AND BALANCE REPORT SHOWING CFM IN OFFICES ETC. | NANCY | NANCY | | H= | P | 4059425 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | P | 09/21/2010 | HVAC FINAL PENDING BALANCE REPORT. | LYNNS | LYNNS | | H= | P | 4042990 |
FOUR BAR MECHANICAL | H= | C | 09/20/2010 | 2- RTU'S AND GAS OK. | LYNNS | LYNNS | | H= | C | 4042157 |
FOUR BAR MECHANICAL | HC | C | 09/17/2010 | INCREASED LOAD FOR 2 NEW ROOF TOP HEATING UNITS. 10 LB TEST | JON | JON | | HC | C | 4041515 |
FOUR BAR MECHANICAL | HI | C | 09/17/2010 | 10 LB TEST GAS TO PLANS | JON | JON | | HI | C | 4041514 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HD | P | 09/17/2010 | LEAVE ALL CEILING OPEN AROUND ALL FIRE SMOKE DAMPERS. TILE OK ELSE WHERE. | JON | JON | | HD | P | 4041503 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HD | P | 08/26/2010 | hard lids only exhaust | JON | JON | | HD | P | 4030412 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HD | P | 08/19/2010 | SMOKE DAMPER FRAMING OK. | LYNNS | LYNNS | | HD | P | 4026700 |
SIMMONS MECHANICAL | P= | C | 09/28/2010 | | LYNNIE | LYNNIE | | P= | C | 4047359 |
SIMMONS MECHANICAL | P= | P | 09/14/2010 | SET DISHWASHER | JOEL | JOEL | | P= | P | 4039233 |
SIMMONS MECHANICAL | PB | C | 08/16/2010 | | JOEL | JOEL | | PB | C | 4024822 |
SIMMONS MECHANICAL | PTO | C | 08/16/2010 | | JOEL | JOEL | | PTO | C | 4024818 |
SIMMONS MECHANICAL | PB | P | 08/11/2010 | DWV TIE-IN O.K | JOEL | JOEL | | PB | P | 4022757 |
SIMMONS MECHANICAL | PB | P | 08/09/2010 | EMPLOYEE RESTROOM AND DRINKING FOUNTAIN O.K | JOEL | JOEL | | PB | P | 4021621 |