GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | C | 11/15/2011 | | DANF | DANF | | B= | C | 4236057 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 09/28/2011 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: rdassero@springsgov.com or 385-7396), External Agency Inspection Z= by ZONING is not Completed yet (Contact: mmaloney@springsgov.com or 385-5080), RIAL HEATING & AIR COND, INC Mechanical Final Inspection is not Completed yet. Need electric/mechanical/fire finals, Remove exit sign in Hall #1069, Need panic hardware at event room #1020 -- Schedule a new Building Final when above items are complete. | MIKE | MIKE | | B= | P | 4214201 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | C | 09/28/2011 | Received structural steel inspection report from Jim Kupper | MIKE | MIKE | | BFR | C | 4214199 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 09/16/2011 | Fire barrier walls at Storage #1201 OK, Need electric rough inspection & structural steel inspection report | MIKE | MIKE | | BFR | P | 4208743 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 08/23/2011 | Interior partition wall framing marked on plans | MIKE | MIKE | | BFR | P | 4197768 |
RIAL HEATING AND AIR CONDITIONING, INC. | BSP | P | 08/18/2011 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical: splice is n/a | DALEH | DALEH | | BSP | P | 4195467 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | T | 08/18/2011 | PAID (REC#994939) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: revised ceiling in room 1201 | SHELLEY | SHELLEY | | BSP | T | 4195448 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 08/17/2011 | Event Rm #1020 - Soffit framing at folding partitions OK, Need structural steel inspection report for partition support | MIKE | MIKE | | BFR | P | 4194940 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 08/08/2011 | interior walls ok- see sheet A 1.04 | BLAKE | BLAKE | | BFR | P | 4190024 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/26/2011 | Area "D" Storage #1201 - Putty packs at back to back boxes OK | MIKE | MIKE | | BFR | P | 4183813 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/25/2011 | Area "D" Storage #1201 - Need to putty pack back to back boxes | MIKE | MIKE | | BFR | P | 4182672 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/20/2011 | Area "C" - Partition walls complete, Area "D" - Storage #1201 need to complete fire barrier walls & horizontal assembly ceiling | MIKE | MIKE | | BFR | P | 4180700 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/14/2011 | Area "B" & "C" - Partition wall framing between 5-9.5 & B-F OK | MIKE | MIKE | | BFR | P | 4177619 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/07/2011 | office wall framing OK; line 1-3, grid B-d.5 | DANF | DANF | | BFR | P | 4173897 |
WEST ELECTRIC GROUP, INC. | E= | C | 09/21/2011 | | MIKEC | MIKEC | | E= | C | 4210755 |
WEST ELECTRIC GROUP, INC. | E= | P | 09/20/2011 | area b | MIKEC | MIKEC | | E= | P | 4209556 |
WEST ELECTRIC GROUP, INC. | ER | P | 09/14/2011 | areas c an d | MIKEC | MIKEC | | ER | P | 4207530 |
WEST ELECTRIC GROUP, INC. | ER | P | 09/13/2011 | area c to col line 11 | MIKEC | MIKEC | | ER | P | 4206798 |
WEST ELECTRIC GROUP, INC. | ER | P | 09/08/2011 | see permit card | MIKEC | MIKEC | | ER | P | 4204874 |
WEST ELECTRIC GROUP, INC. | ER | P | 08/29/2011 | ceiling area b | MIKEC | MIKEC | | ER | P | 4200342 |
WEST ELECTRIC GROUP, INC. | ER | P | 07/19/2011 | walls | MIKEC | MIKEC | | ER | P | 4180208 |
WEST ELECTRIC GROUP, INC. | ER | P | 07/14/2011 | walls area c | MIKEC | MIKEC | | ER | P | 4178030 |
WEST ELECTRIC GROUP, INC. | ER | P | 07/08/2011 | walls area b | MIKEC | MIKEC | | ER | P | 4174749 |
WEST ELECTRIC GROUP, INC. | ER | R | 07/07/2011 | provide point of contact----- called contractors office and spent 25 minutes trying to locate electrician | MATTHEW | MATTHEW | | ER | R | 4173932 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | C | 11/09/2011 | RECEIVED BALANCE REPORT | JON | JON | | H= | C | 4233563 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | P | 09/13/2011 | HVAC FINAL PENDING BALANCE REPORT. | LYNNS | LYNNS | | H= | P | 4206533 |
OLSON PLUMBING & HEATING COMPANY | H= | C | 09/12/2011 | HWP FINAL. | LYNNS | LYNNS | | H= | C | 4206188 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | P | 09/09/2011 | FINAL ABOVE CEILING IN AREA "C". OK FOR TILE. | LYNNS | LYNNS | | H= | P | 4205268 |
RIAL HEATING AND AIR CONDITIONING, INC. | HD | P | 09/09/2011 | ROUGH DUCT IN AREA "A" AT LUNCH ROOM. | LYNNS | LYNNS | | HD | P | 4205261 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | P | 08/25/2011 | ABOVE CEILING FINAL FOR AREA "B" ONLY. NEED BALANCE REPORT AT COMPLETION OF PERMIT WORK. | LYNNS | LYNNS | | H= | P | 4198639 |
OLSON PLUMBING & HEATING COMPANY | HWP | P | 08/03/2011 | HWP OK TO INSULATE EXISTING AND BRANCH LINES. | LYNNS | LYNNS | | HWP | P | 4187680 |