COLARELLI CONSTRUCTION, INC. | B= | C | 03/19/2014 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4705527 |
COLARELLI CONSTRUCTION, INC. | BSP | T | 02/24/2014 | PAID (REC#1180579) ADDITIONAL PLAN REVIEW TIME: $50 From: TCRIPPEN new splice page see clouds | TCRIPPEN | TCRIPPEN | | BSP | T | 4691716 |
COLARELLI CONSTRUCTION, INC. | B= | P | 02/21/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet, LANDMARK PLUMBING & HTG, INC. Plumbing Final Inspection is not Completed yet, RYBA ELECTRIC, INC. Electrical Final Inspection is not Completed yet, SS ELECTRICAL SERVICES LLC Electrical Final Inspection is not Completed yet. | CHRISM | CHRISM | | B= | P | 4691416 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 02/18/2014 | walls ok in admin area | CHRISM | CHRISM | | BFR | P | 4689021 |
RYBA ELECTRIC, INC. | BSP | P | 01/28/2014 | PLAN SPLICE: (No Fee) by: DOUG for Electrical | DOUG | DOUG | | BSP | P | 4678899 |
HVAC SOLUTIONS, INC. | BSP | P | 01/28/2014 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical | DALEH | DALEH | | BSP | P | 4678868 |
COLARELLI CONSTRUCTION, INC. | BSP | T | 01/28/2014 | PAID (REC#1176976) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: Add offices | MICHAELA | MICHAELA | | BSP | T | 4678847 |
COLARELLI CONSTRUCTION, INC. | B= | P | 01/24/2014 | Temp CO: All paritalled ( Expires: 2/23/2014 12:00:00 AM) | JANE | JANE | | B= | P | 4677185 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 01/09/2014 | | CHRISM | CHRISM | | BFR | P | 4669279 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 01/08/2014 | wall framing ok pending other roughs | CHRISM | CHRISM | | BFR | P | 4668623 |
COLARELLI CONSTRUCTION, INC. | BSP | T | 01/03/2014 | PAID (REC#1173545) ADDITIONAL PLAN REVIEW TIME: $50 From: TCRIPPEN new splice pages see clouds | TCRIPPEN | TCRIPPEN | | BSP | T | 4666099 |
COLARELLI CONSTRUCTION, INC. | B= | P | 12/03/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet, LANDMARK PLUMBING & HTG, INC. Plumbing Final Inspection is not Completed yet, RYBA ELECTRIC, INC. Electrical Final Inspection is not Completed yet, SS ELECTRICAL SERVICES LLC Electrical Final Inspection is not Completed yet. ok pending other finals, surgery center not complete, suite numbers -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4651316 |
COLARELLI CONSTRUCTION, INC. | BSP | P | 11/13/2013 | met with supt Mike about rated walls in surgery center | CHRISM | CHRISM | | BSP | P | 4640620 |
HVAC SOLUTIONS, INC. | BSP | T | 10/14/2013 | PAID (REC#1162143): PLAN SPLICE FEE: $50 by: DALEH for Mechanical | DALEH | DALEH | | BSP | T | 4622139 |
COLARELLI CONSTRUCTION, INC. | BSP | T | 10/14/2013 | PAID (REC#1166036) ADDITIONAL PLAN REVIEW TIME: $50 From: SHELBY | SHELBY | SHELBY | | BSP | T | 4622101 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 10/11/2013 | Office wall framing OK; need to complete framing of operation room fire partitions and office walls; need framing completed at shaft ; need detail to support rated construction of operation room above. | DANF | DANF | | BFR | P | 4621078 |
RYBA ELECTRIC, INC. | E= | C | 03/19/2014 | | GARYL | GARYL | | E= | C | 4705265 |
STILSON ELECTRIC SYSTEMS, INC. | E= | C | 03/18/2014 | FIRE ALARM INSPECTION: | GARYL | GARYL | | E= | C | 4704351 |
STILSON ELECTRIC SYSTEMS, INC. | E= | P | 03/07/2014 | FIRE ALARM INSPECTION: FIRE ALARM=== rooms 280==289==293===294== | BRIAN | BRIAN | | E= | P | 4698938 |
STILSON ELECTRIC SYSTEMS, INC. | ER | P | 03/07/2014 | FIRE ALARM INSPECTION: rooms 280--289---293---294---offices | BRIAN | BRIAN | | ER | P | 4698937 |
RYBA ELECTRIC, INC. | ER | P | 03/07/2014 | ROOMS--280---289--293---294----CEILINGS OK----MARKED ON DRAWINGS--- ( OFFICES ) | BRIAN | BRIAN | | ER | P | 4698927 |
STILSON ELECTRIC SYSTEMS, INC. | ER | P | 02/27/2014 | FIRE ALARM INSPECTION: Suite 200 ok | GARYL | GARYL | | ER | P | 4694388 |
RYBA ELECTRIC, INC. | E= | P | 02/20/2014 | Receptacle not made up in front exam area over desk, need panel directory for this phase/offices. | GARYL | GARYL | | E= | P | 4690241 |
RYBA ELECTRIC, INC. | ER | P | 02/18/2014 | walls only in admin room | GARYL | GARYL | | ER | P | 4688371 |
RYBA ELECTRIC, INC. | ER | P | 02/14/2014 | all ceilings ok | GARYL | GARYL | | ER | P | 4687589 |
RYBA ELECTRIC, INC. | ER | P | 02/05/2014 | rooms 249---248---266--291--297---290--- hard lids | BRIAN | BRIAN | | ER | P | 4683431 |
RYBA ELECTRIC, INC. | ER | P | 01/15/2014 | walls only | GARYL | GARYL | | ER | P | 4672299 |
RYBA ELECTRIC, INC. | E= | P | 11/26/2013 | need office furniture installed, light stays on all the time in lab., ?? | GARYL | GARYL | | E= | P | 4648388 |
RYBA ELECTRIC, INC. | EP | P | 11/22/2013 | Transformer to lighting panel | GARYL | GARYL | | EP | P | 4646993 |
RYBA ELECTRIC, INC. | EP | C | 11/22/2013 | basement gear to 2nd floor panel | GARYL | GARYL | | EP | C | 4646991 |
RYBA ELECTRIC, INC. | ER | P | 11/19/2013 | ceilings through out | GARYL | GARYL | | ER | P | 4644596 |
RYBA ELECTRIC, INC. | ER | P | 11/18/2013 | CEILINGS IN EXAM ROOMS OK--- | BRIAN | BRIAN | | ER | P | 4643565 |
STILSON ELECTRIC SYSTEMS, INC. | ER | P | 11/13/2013 | FIRE ALARM INSPECTION: all ceilings | GARYL | GARYL | | ER | P | 4641052 |
RYBA ELECTRIC, INC. | ER | P | 10/28/2013 | 2nd floor reception 1, and reception 2, soffits | GARYL | GARYL | | ER | P | 4630684 |
RYBA ELECTRIC, INC. | ER | P | 10/15/2013 | Prints on site with corrected splice | GARYL | GARYL | | ER | P | 4622744 |
RYBA ELECTRIC, INC. | ER | R | 10/11/2013 | need revised prints to show correct exam rooms where they are-------- 4 apprentices and no license on site | GARYL | GARYL | | ER | R | 4621242 |
HVAC SOLUTIONS, INC. | H= | C | 03/19/2014 | TEST AND BALANCE REPORT RECEIVED. | NANCY | NANCY | | H= | C | 4705526 |
HVAC SOLUTIONS, INC. | H= | P | 03/19/2014 | MECHANICAL FINAL OK PENDING RECEIPT OF TEST AND BALANCE REPORT FOR NORTH EAST CORNER AND SURGERY AREA.TEST AND BALANCE REPORT ALREADY RECEIVED FOR REST OF FINISHED AREA. | NANCY | NANCY | | H= | P | 4704896 |
HVAC SOLUTIONS, INC. | HD | P | 02/20/2014 | SOUTHEAST CORNER. ROUGH DUCTS AND LATERALS ABOVE CEILING OK, OK TO WRAP. NO VAV'S OR DIFFUSERS YET. | NANCY | NANCY | | HD | P | 4690588 |
HVAC SOLUTIONS, INC. | HD | P | 02/14/2014 | Note added 2/20/14. Changed inspection to partial. More rough inspections required due to extra work in south east corner. See splice dated 1/28/14. FOR FINAL ISOLATE WATER HEATER PVC DRAIN FROM RETURN AIR PLENUM. LABEL GRID WITH DAMPER LOCATION. PROVIDE TEST AND BALANCE REPORT FOR SURGERY AREA ONLY. | NANCY | NANCY | | HD | P | 4687455 |
HVAC SOLUTIONS, INC. | HD | P | 01/31/2014 | ALL FIRE DAMPERS OK. FOUR BATH EXHAUST ABOVE CEILING OK. | NANCY | NANCY | | HD | P | 4681572 |
HVAC SOLUTIONS, INC. | HD | P | 01/27/2014 | NO ACCESS TO PRINTS TODAY. ALL FIRE/SMOKE DAMPERS INSTALLATION OK EXCEPT STILL NEED TO INSTALL RETAINING ANGLES ON DAMPER ABOVE DOOR IN NORTH HALLWAY. | NANCY | NANCY | | HD | P | 4678321 |
HVAC SOLUTIONS, INC. | HD | P | 01/23/2014 | SHEET M1.00. YELLOW HIGHLIGHTS DAMPER INSTALLATION ALL COMPLETE OR NEED RETAINING ANGLES ON ONE SIDE OF WALL. | NANCY | NANCY | | HD | P | 4676707 |
HVAC SOLUTIONS, INC. | HD | P | 01/21/2014 | SHEET M1.00. HIGHLIGHTED SIDE OF WALL AT FIRE/SMOKE DAMPER ALL OK. OK FOR TILES PER MECHANICAL ONLY. WILL STILL NEED TO SEE OTHER SIDE OF WALL WHICH IS NOT COMPLETE YET. | NANCY | NANCY | | HD | P | 4674836 |
HVAC SOLUTIONS, INC. | HD | P | 01/15/2014 | SHEET M1.00. FIRE/SMOKE DAMPER FRAMING OK. NOTED DAMPERS INSTALLED, OK FOR ANGLES. | NANCY | NANCY | | HD | P | 4672164 |
HVAC SOLUTIONS, INC. | HD | P | 01/13/2014 | SEE REVISED M1.00 FOR DATE AND SIGNATURE. FIRE.SMOKE DAMPER FRAMING OK. NOTED DAMPERS INSTALLED, OK FOR ANGLES. | NANCY | NANCY | | HD | P | 4671082 |
HVAC SOLUTIONS, INC. | H= | P | 12/16/2013 | NEW PRINT APPROVED AND SCANNED. TEST AND BALANCE REPORT MATCHES NEW PRINT. WILL NEED INSPECTIONS AND TEST AND BALANCE REPORT FOR SURGERY AND SURROUNDING AREAS. | NANCY | NANCY | | H= | P | 4657984 |
HVAC SOLUTIONS, INC. | H= | P | 12/16/2013 | REVISED TEST AND BALANCE REPORT RECEIVED. DOES NOT MATCH THE STAMPED SET DATED 7/17/13. HAVE REVISED PRINTS BEEN SUBMITTED TO RBD YET? | NANCY | NANCY | | H= | P | 4657170 |
HVAC SOLUTIONS, INC. | H= | P | 12/09/2013 | TEST AND BALANCE REPORT RECEIVED. READINGS DO NOT MATCH PRINTS. ONLY EF5 SHOWN ON REPORT, THERE ARE SIX EXHAUST FANS ON PRINT. VAV READINGS DO NOT MATCH, NUMBER OF DIFFUSERS AND CFM READINGS ARE DIFFERENT. | NANCY | NANCY | | H= | P | 4653765 |
HVAC SOLUTIONS, INC. | H= | P | 12/06/2013 | MECHANICAL FINAL OK PENDING ROUGH AND FINAL INSPECTIONS ON OPERATING AND ADJACENT ROOMS. DAMPER FRAMING HAS NOT BEEN LOOKED AT, DO NOT COVER. PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4653264 |
HVAC SOLUTIONS, INC. | H= | P | 11/27/2013 | SEE SHEET M1.00. ABOVE CEILING OK EXCEPT FOR OR AND ADJACENT AREAS. ROOF ACCESS LOCKED TODAY, WILL NEED ACCESS TO ROOF FOR FINAL. PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4649350 |
HVAC SOLUTIONS, INC. | HD | P | 11/14/2013 | SEE SHEET M1.00. CIRCLED AREA AND CIRCLED ROOM NUMBERS ABOVE CEILING OK. | NANCY | NANCY | | HD | P | 4642194 |
HVAC SOLUTIONS, INC. | HD | P | 10/29/2013 | SEE SHEET M1.00. MEDIUM/LOW PRESSURE DUCTS OK, OK TO WRAP. | NANCY | NANCY | | HD | P | 4631790 |
HVAC SOLUTIONS, INC. | HD | P | 10/24/2013 | SEE REVISED SHEET M100. VAV'S, MEDIUM AND LOW PRESSURE DUCTS OK, OK TO WRAP. CALL INSPECTION FOR THREE FIRE DAMPERS THROUGH WALL, NEED FRAMING INSTRUCTIONS ON SITE. | NANCY | NANCY | | HD | P | 4629164 |
HVAC SOLUTIONS, INC. | HD | P | 09/19/2013 | SEE SHEET M1.0 FOR DATE AND SIGNATURE. MEDIUM/LOW PRESSURE DUCTS OK, OK TO WRAP LOW PRESSURE. VERIFY SMOKE DETECTION AT MAIN RETURN AIR. NEED REVISED/APPROVED PRINTS BY FINAL. | NANCY | NANCY | | HD | P | 4607517 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 02/25/2014 | correction made plan revised and spiced. | DICK | DICK | | P= | C | 4692599 |
LANDMARK PLUMBING AND HEATING, INC. | P= | T | 02/20/2014 | PAID (REC#1180580) h2o not sized properly | JOEL | JOEL | | P= | T | 4690159 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 12/31/2013 | walls o.k pending approved drawing to include new h2o layout | JOEL | JOEL | | PTO | P | 4664813 |
LANDMARK PLUMBING AND HEATING, INC. | P= | L | 12/24/2013 | WRONG INSPECTION CALLED IN | LEE | LEE | | P= | L | 4662306 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | R | 12/24/2013 | UNDER FLOOR / RISERS DWV ONLY -- N/E CORNER -- NEED PLANS REVISED TO SHOW ALL CHANGES (SINKS HAVE BEEN RELOCATED -- MOP SINK RELOCATED - ETC) | LEE | LEE | | PTO | R | 4662304 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 12/03/2013 | 1- rest room in south end and 6-exam sinks o.k | JOEL | JOEL | | P= | P | 4651801 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 11/20/2013 | | JOEL | JOEL | | PTO | P | 4645412 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | R | 10/18/2013 | NORTH SIDE 1ST FLOOR CEILING 2" BACKGRADED TO SINK AND 3" BACKGRADED TO W/C -- N/W CORNER TWO SINKS 2ND FLOOR OK WALLS ONLY | LEE | LEE | | PTO | R | 4625009 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 10/15/2013 | SOUTH HALF WALLS OK -- PENDING ABS TO PVC GLUED TEST TEE GETS REPLACED -- ALSO OVERHEAD COLD WATER UNDERSIZED AT RESTROOM | LEE | LEE | | PTO | P | 4622505 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 09/12/2013 | under floor dwv ok | TIM | TIM | | PTO | P | 4603297 |