GILLIS HOMES, INC. | B= | C | 10/29/2015 | | DALE | DALE | | B= | C | 5068481 |
GILLIS HOMES, INC. | BE | L | 07/23/2015 | Renewed for Full Fee at 7/23/2015 3:27:34 PM (Receipt#1276318) | MINDY | MINDY | | BE | L | 4999815 |
GILLIS HOMES, INC. | B= | P | 06/12/2014 | Temp CO: pending building final ( Expires: 7/12/2014 12:00:00 AM) | MINDY | MINDY | | B= | P | 4756942 |
GILLIS HOMES, INC. | B= | P | 06/12/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. final grade, address numbers on house, complete exterior, deck not built rear door blocked -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4756835 |
GILLIS HOMES, INC. | BFN | C | 03/19/2014 | eng report on file | CHRISM | CHRISM | | BFN | C | 4705492 |
GILLIS HOMES, INC. | BFT | C | 03/19/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4705490 |
GILLIS HOMES, INC. | BIN | C | 03/19/2014 | finished basement | CHRISM | CHRISM | | BIN | C | 4705402 |
GILLIS HOMES, INC. | BFR | C | 03/19/2014 | | CHRISM | CHRISM | | BFR | C | 4705401 |
GILLIS HOMES, INC. | BFR | R | 03/14/2014 | ok to insulate, windbrace and strongback front gables, missing H2.5s at dormer rafters, strap bay walls to house, trusses are designed with ridgid ceiling attatched to bottom cords-eng to evaluate bottom cord bracing where ceilings are dropped | CHRISM | CHRISM | | BFR | R | 4702801 |
GILLIS HOMES, INC. | BFR | R | 03/13/2014 | no frame inspection until BFT, BFN, bFD and foundation insulation are completed, I havenot received eng inspection reports , basement slab was poured without insulation inspection | CHRISM | CHRISM | | BFR | R | 4701835 |
GILLIS HOMES, INC. | BSP | T | 03/11/2014 | PAID (REC#1183272) PLAN SPLICE FEE: $50 by: DALEH for Mechanical | DALEH | DALEH | | BSP | T | 4700636 |
GILLIS HOMES, INC. | BSP | T | 03/11/2014 | PAID (REC#1183272) PLAN SPLICE FEE: $50 by: DANM for Construction: Added dormer and swapped bath and stairs | DANM | DANM | | BSP | T | 4700570 |
GILLIS HOMES, INC. | BFN | P | 10/10/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4620537 |
GILLIS HOMES, INC. | BFT | P | 10/10/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4620536 |
HOMEOWNER | E= | C | 06/11/2014 | | MATTHEW | MATTHEW | | E= | C | 4756185 |
HOMEOWNER | E= | R | 06/10/2014 | still need afci protection for outlets on 1/2 wall at living room and dining room | MATTHEW | MATTHEW | | E= | R | 4754991 |
HOMEOWNER | E= | R | 06/09/2014 | can't have gfci device above oven, reverse polarity tv outlet in master bedroom, no power to laundry room outlet, 20.83 amps of loft baseboard heat (decrease wattage to 2800w), afci protect per 2011 nec (only bedrooms protected at this time), seal around front exterior outlet, need connector at furnace-------a/c pre-wire | MATTHEW | MATTHEW | | E= | R | 4754329 |
HOMEOWNER | ER | C | 03/07/2014 | | MATTHEW | MATTHEW | | ER | C | 4698997 |
HOMEOWNER | ER | R | 03/06/2014 | add outlets--back side of island, right of back door, and left of fireplace--trim box in attic at front hall, outlet left of front door can't be on small appliance circuit---------- finished basement, no mcc's | MATTHEW | MATTHEW | | ER | R | 4698152 |
HOMEOWNER | ES | C | 03/06/2014 | Residential Overhead: 200 amp 3/w new res: meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4698143 |
HOMEOWNER | EUG | C | 11/04/2013 | service lateral ok | MATTHEW | MATTHEW | | EUG | C | 4635423 |
HOMEOWNER | H= | C | 06/09/2014 | Final ok. Note: Fin Bsmnt, Hi/Lo grills to mech closet. line set rough only. | MARK | MARK | | H= | C | 4753875 |
KNAUF HEATING AND AIR CONDITIONING | HC | C | 03/12/2014 | RELEASE METER | MARK | MARK | | HC | C | 4701188 |
KNAUF HEATING AND AIR CONDITIONING | HI | C | 03/12/2014 | Stub for bbq has been extended. Ok. | MARK | MARK | | HI | C | 4701187 |
KNAUF HEATING AND AIR CONDITIONING | HRR | C | 03/12/2014 | Framing completed, bath fan added. All ok. Note: Loft to be heated by electric baseboard. Plans spliced for electrical. | MARK | MARK | | HRR | C | 4701179 |
KNAUF HEATING AND AIR CONDITIONING | HI | R | 03/06/2014 | need to pipe bbq outlet for upper deck to outside framing, note: 1 1/4'' furnace, 2-water heaters, fireplace, range, 2-bbq (upper and lower), outlet in basement wet bar area | TED | TED | | HI | R | 4698265 |
KNAUF HEATING AND AIR CONDITIONING | HRR | R | 03/06/2014 | complete fireplace framing, need 2nd bath fan and vent in basement hall bathroom over tub/shower area, what about heat for loft ?, note: finished basement, a/c rough, duct design | TED | TED | | HRR | R | 4698258 |
HOMEOWNER | P= | C | 06/11/2014 | NOTE : FINISHED BASEMENT W/KITCHEN . PVB INSTALLED | GABE | GABE | | P= | C | 4755592 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 03/07/2014 | vent for master shower not in frame ? finished basement | DICK | DICK | | PTO | C | 4699066 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 10/30/2013 | | TIM | TIM | | PB | C | 4632552 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | P | 10/29/2013 | field cancel | TIM | TIM | | PB | P | 4631135 |