DOUBLE DIAMOND HOMES, INC. | B= | C | 03/03/2014 | | CHRISM | CHRISM | | B= | C | 4695772 |
DOUBLE DIAMOND HOMES, INC. | B= | P | 02/28/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet. missing egress ladder at bedroom window well -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4694870 |
DOUBLE DIAMOND HOMES, INC. | BLA | C | 01/09/2014 | | CHRISM | CHRISM | | BLA | C | 4668956 |
DOUBLE DIAMOND HOMES, INC. | BIN | C | 12/18/2013 | | CHRISM | CHRISM | | BIN | C | 4659217 |
DOUBLE DIAMOND HOMES, INC. | BFR | C | 12/17/2013 | | CHRISM | CHRISM | | BFR | C | 4658327 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 12/16/2013 | EPDM installed at decks | CHRISM | CHRISM | | BSP | P | 4657327 |
DOUBLE DIAMOND HOMES, INC. | BFR | R | 12/16/2013 | ok to insulate, strap plates at rake wall, nail off truss hangers | CHRISM | CHRISM | | BFR | R | 4657326 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 12/10/2013 | deck framing ang columns ok, deck cover and posts ok, eng letter on file for deck piers | CHRISM | CHRISM | | BSP | P | 4654417 |
DOUBLE DIAMOND HOMES, INC. | BFD | C | 10/31/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4633146 |
DOUBLE DIAMOND HOMES, INC. | BFI | C | 10/31/2013 | R-10 at walkout walls ok | CHRISM | CHRISM | | BFI | C | 4633135 |
DOUBLE DIAMOND HOMES, INC. | BFN | C | 10/31/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4633134 |
DOUBLE DIAMOND HOMES, INC. | BFT | C | 10/31/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4633133 |
POLARIZED ELECTRIC INC | E= | C | 02/26/2014 | 30 amp a/c ok | MATTHEW | MATTHEW | | E= | C | 4693596 |
POLARIZED ELECTRIC INC | E= | R | 02/21/2014 | corrections made------ builder said a/c to be installed tuesday | MATTHEW | MATTHEW | | E= | R | 4691204 |
POLARIZED ELECTRIC INC | E= | R | 02/18/2014 | expose ufer and water grounding electrode conductor, need washer in basement bath room gfci protected at breaker, afci protect wet bar, master closet lights too close to shelves, enclose basement bedroom closet light, neutral bonded at a/c disconnect---------- a/c pre-wire | MATTHEW | MATTHEW | | E= | R | 4688550 |
POLARIZED ELECTRIC INC | ES | C | 12/12/2013 | Residential Underground: 200 AMP NEW RES OK | BRIAN | BRIAN | | ES | C | 4655972 |
POLARIZED ELECTRIC INC | ER | C | 12/12/2013 | FINISHED BASEMENT------NEED ACCESS TO UFER AND COLD WATER ON FINAL | BRIAN | BRIAN | | ER | C | 4655963 |
POLARIZED ELECTRIC INC | EUG | C | 12/03/2013 | service lateral from pedestal to house--------------- permit description is temp service; need permit info transfered to house permit | MATTHEW | MATTHEW | | EUG | C | 4652026 |
BRUNO'S HEATING & COOLING | H= | C | 02/26/2014 | finished basement, has a/c. hi/lo transfer air. | DICK | DICK | | H= | C | 4693578 |
CORNERSTONE PLUMBING INC | HC | C | 12/06/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4653505 |
CORNERSTONE PLUMBING INC | HI | C | 12/06/2013 | 10# test ok. 1 1/4" main to furn, w/h, fp, range, 3/4" future stub to generator not to exceed 100k. Note: wood burner has no gas. | MICHAELS | MICHAELS | | HI | C | 4653503 |
BRUNO'S HEATING & COOLING | HRR | C | 12/05/2013 | osa damper not needed. | MICHAELS | MICHAELS | | HRR | C | 4652777 |
BRUNO'S HEATING & COOLING | HRR | P | 12/03/2013 | Need damper on osa per plan, rest ok. Note: duct design, FB, 6" osa, a/c rough(coil and lineset), direct vent furnace. | MICHAELS | MICHAELS | | HRR | P | 4651637 |
CORNERSTONE PLUMBING INC | P= | C | 02/27/2014 | corrections made. finished basement. | DICK | DICK | | P= | C | 4694166 |
CORNERSTONE PLUMBING INC | P= | P | 02/26/2014 | two lavs leaking in basement. missing pvb. | DICK | DICK | | P= | P | 4693571 |
HOMEOWNER | PWO | C | 12/18/2013 | | TIM | TIM | | PWO | C | 4659622 |
CORNERSTONE PLUMBING INC | PTO | C | 12/09/2013 | | TIM | TIM | | PTO | C | 4654069 |
CORNERSTONE PLUMBING INC | PTO | P | 12/06/2013 | dwv ok finish h2o and test | TIM | TIM | | PTO | P | 4653696 |
CORNERSTONE PLUMBING INC | PB | C | 11/08/2013 | | JOEL | JOEL | | PB | C | 4638608 |