BUILTRITE BUILDERS | B= | C | 07/29/2015 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 5003120 |
BUILTRITE BUILDERS | B= | P | 07/28/2015 | . Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 5002955 |
BUILTRITE BUILDERS | BLA | C | 06/02/2015 | | DALE | DALE | | BLA | C | 4965276 |
BUILTRITE BUILDERS | BIN | C | 05/12/2015 | | DALE | DALE | | BIN | C | 4953392 |
BUILTRITE BUILDERS | BFR | C | 05/12/2015 | | DALE | DALE | | BFR | C | 4953391 |
BUILTRITE BUILDERS | BFR | R | 05/11/2015 | cardboard is not a firestop | DALE | DALE | | BFR | R | 4952339 |
BUILTRITE BUILDERS | BIN | R | 05/11/2015 | insulate above electric cans at room above garage | DALE | DALE | | BIN | R | 4952310 |
BUILTRITE BUILDERS | BFR | P | 05/06/2015 | still need fireblock thru-out / eng. truss repair on file | DALE | DALE | | BFR | P | 4949909 |
BUILTRITE BUILDERS | BFR | R | 05/05/2015 | anchors missing at garage / clips missing on girder trusses / strap top plates thru-out / fireblock thru-out | DALE | DALE | | BFR | R | 4949441 |
BUILTRITE BUILDERS | BTR | C | 04/09/2015 | | DALE | DALE | | BTR | C | 4932707 |
BUILTRITE BUILDERS | BSP | P | 03/13/2015 | front porch with posts okay / rear porch with posts down to foundation okay | BOBF | BOBF | | BSP | P | 4917231 |
BUILTRITE BUILDERS | BFI | C | 01/23/2015 | | DALE | DALE | | BFI | C | 4889559 |
BUILTRITE BUILDERS | BFT | C | 01/23/2015 | ok per eng. | DALE | DALE | | BFT | C | 4889558 |
BUILTRITE BUILDERS | BFN | C | 01/23/2015 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4889551 |
BUILTRITE BUILDERS | BFD | C | 01/23/2015 | | DALE | DALE | | BFD | C | 4889550 |
BUILTRITE BUILDERS | BFN | P | 01/21/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4888565 |
BUILTRITE BUILDERS | BFT | P | 01/21/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4888564 |
HOMERUN ELECTRONICS, INC. | E= | C | 07/24/2015 | | CRAIG | CRAIG | | E= | C | 5000868 |
HOMERUN ELECTRONICS, INC. | E= | R | 07/22/2015 | could not complete inspection: need switching set up for final-------- inspected outside: a/c 1-28.1-45 a/c 2- 12-20, outlet on upper deck by door no power, provide paperwork for deck heaters, where is switch for x-mas light---- inspected garage, main level (pendant light in tub zone, pantry light switch not working, no switching for kitchen and master bath lights, and inspected upper loft with wet bar rough only: could not get lighting in loft or stairs to work | MATTHEW | MATTHEW | | E= | R | 4998937 |
HOMERUN ELECTRONICS, INC. | ER | C | 05/01/2015 | correction made | CRAIG | CRAIG | | ER | C | 4947775 |
HOMERUN ELECTRONICS, INC. | ES | C | 04/28/2015 | Residential Underground: 200 amp 3/w: new res | MATTHEW | MATTHEW | | ES | C | 4944770 |
HOMERUN ELECTRONICS, INC. | ER | R | 04/28/2015 | install nm connector wedge in cen can connectors, wirenut grounds at smokes and lights, tc cable needs to be installed in raceway, need raceway for cold leads for floor heat, box non ic cans above cooking equipment and correct clearance from combustibles, missing can light above fireplace--------- finished basement, 4/0 al sub-panel ok at 200 amp, 2-20 at service, 6-3nm from service panel stub, cen vac installed | MATTHEW | MATTHEW | | ER | R | 4944767 |
HOMERUN ELECTRONICS, INC. | EUG | C | 01/29/2015 | service lateral from ped to home | MATTHEW | MATTHEW | | EUG | C | 4893085 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/22/2015 | NOTE: HAS TWO COMPLETE A/C'S, TWO DIRECT VENT FURNACES, HIGH LOW COMBUSTION AIR GRILLS TO MECHANICAL ROOM, MANTEL GOOD. FINISHED BASEMENT.. | LUKE | LUKE | | H= | C | 4998109 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/21/2015 | GOOD. NOTE: HAS TWO A/C COMPLETE, FINISHED BASEMENT, DIRECT VENT FURNACES, HIGH LOW COMBUSTION AIR GRILLS TO MECHANICAL ROOM. MANTEL GOOD. | LUKE | LUKE | | H= | P | 4997966 |
RIDGEVIEW PLUMBING | HC | C | 05/05/2015 | RELEASE METER | MARK | MARK | | HC | C | 4949092 |
RIDGEVIEW PLUMBING | HI | C | 05/05/2015 | 10 lb test ok. Note: 1 1/4" main with meter at house. 2- furn, 2- w/h, cook top, f/p, fut bbq. | MARK | MARK | | HI | C | 4949085 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/29/2015 | All ok. | MARK | MARK | | HRR | C | 4945545 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/28/2015 | Need to pan off return at soffit in b/r #3. Rest ok. Note: Equip matches, has a fin. bsmnt, 2- sealed comb furn, 1- a/c rough 2- OSA to ret. | MARK | MARK | | HRR | P | 4944364 |
RIDGEVIEW PLUMBING | HI | R | 04/17/2015 | Low test. Reinspect all. | MARK | MARK | | HI | R | 4937871 |
RIDGEVIEW PLUMBING | P= | C | 07/23/2015 | | TIM | TIM | | P= | C | 4999713 |
RIDGEVIEW PLUMBING | PWO | C | 04/22/2015 | need certificate of potable water by final | TED | TED | | PWO | C | 4940599 |
RIDGEVIEW PLUMBING | PTO | C | 04/16/2015 | finished basement | TED | TED | | PTO | C | 4937261 |
RIDGEVIEW PLUMBING | PB | C | 01/30/2015 | corrections made | TIM | TIM | | PB | C | 4893504 |
RIDGEVIEW PLUMBING | PB | P | 01/29/2015 | floor drain is s trapped | TIM | TIM | | PB | P | 4892725 |