TIFFANY HOMES, LLC. | B= | C | 10/02/2015 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 5049927 |
TIFFANY HOMES, LLC. | B= | P | 10/02/2015 | items corrected. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DANE | DANE | | B= | P | 5049520 |
TIFFANY HOMES, LLC. | B= | P | 09/30/2015 | need continious graspable rail from main level up to landing / guard rail on landing needs to be a minimum of 36" above finished floor and is only 35" -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DANE | DANE | | B= | P | 5047904 |
TIFFANY HOMES, LLC. | BLA | C | 08/05/2015 | item corrected | DANE | DANE | | BLA | C | 5008488 |
TIFFANY HOMES, LLC. | BLA | P | 08/03/2015 | weep screed at post at patio needs to be above the line of the concrete | DANE | DANE | | BLA | P | 5006840 |
TIFFANY HOMES, LLC. | BFR | C | 07/21/2015 | sheer nailing on interior OK | DANE | DANE | | BFR | C | 4997300 |
TIFFANY HOMES, LLC. | BIN | C | 07/20/2015 | wall insulation complete | DANE | DANE | | BIN | C | 4996447 |
TIFFANY HOMES, LLC. | BFR | P | 07/20/2015 | engineering on file for post not setting in center of beam, for hanger for 14" LVL above kitchen, for dropped joists in shower, kitchen header, and narrow brace wall in northeast corner of upper floor / all items corrected from previous inspections / need to see nailing for sheer in northeast bedroom | DANE | DANE | | BFR | P | 4996438 |
TIFFANY HOMES, LLC. | BFR | P | 07/15/2015 | OK to insulate / plan calls dbl 11 7/8 lvl and narrow brace wall at north east bedroom windows / need engineering for post by stairs on main level not bearing in center of beam and for 3 2x6 post for 14" LVL next to stairs / plan calls DBL 9 1/2" LVL at kitchen window / plan calls WP14 hanger at LVL to steel beam connection above kitchen / strap first flight of stairs going to upper level / need to redhead landing ledger in basement / need to strap corner of basement landing to upper level / secure steel posts in main loor system / missing PL at west end by stairs to steel beam | DANE | DANE | | BFR | P | 4993740 |
TIFFANY HOMES, LLC. | BSP | P | 07/02/2015 | all truss bracing, truss posts and hardware OK except need to nail off hangers holding 14" ML in garage that holds trusses above 2 car door and need 3 2x4 post in bearing wall under AO16G at top of stairs / truss engineer fixes on file for B07 , B08 and B09 trusses / truss repairs done correctly | DANE | DANE | | BSP | P | 4985873 |
TIFFANY HOMES, LLC. | BSP | P | 06/25/2015 | Engineering on file for deck footings / front porch lid OK / rear deck posts and rear porch lid OK / deck still needs inspection / front porch posts still need inspection | DANE | DANE | | BSP | P | 4980606 |
TIFFANY HOMES, LLC. | BFN | C | 04/10/2015 | foundation engineering on file | DANE | DANE | | BFN | C | 4933144 |
TIFFANY HOMES, LLC. | BFI | C | 04/09/2015 | | DANE | DANE | | BFI | C | 4932787 |
TIFFANY HOMES, LLC. | BFD | C | 04/09/2015 | | DANE | DANE | | BFD | C | 4932786 |
TIFFANY HOMES, LLC. | BFN | P | 04/09/2015 | need design/engineer inspection report on file/5% slope/open hole on file/soils on file/1500 PSF/eufer noted/usable drain | DANE | DANE | | BFN | P | 4932785 |
TIFFANY HOMES, LLC. | BFT | C | 04/09/2015 | engineer inspection report on file | DANE | DANE | | BFT | C | 4932784 |
TIFFANY HOMES, LLC. | BFN | P | 03/11/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 4915073 |
TIFFANY HOMES, LLC. | BFT | P | 03/11/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 4915072 |
D & J QUALITY ELECTRIC INC | E= | C | 09/17/2015 | 25 AMP A.C | MIKEC | MIKEC | | E= | C | 5038689 |
D & J QUALITY ELECTRIC INC | ES | C | 07/14/2015 | Residential Underground: NEW 320 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4992841 |
D & J QUALITY ELECTRIC INC | ER | C | 07/14/2015 | UNFINISHED BASEMENT NO CEN. VAC | MIKEC | MIKEC | | ER | C | 4992839 |
THE FURNACE GUY HEATING & COOLING | H= | C | 09/17/2015 | Corrections made. | STEVEC | STEVEC | | H= | C | 5038728 |
THE FURNACE GUY HEATING & COOLING | H= | P | 09/16/2015 | Seal line-set at exterior to condenser, provide ladder to access attic furnace. Note: rest o.k. letters received. | STEVEC | STEVEC | | H= | P | 5037929 |
THE FURNACE GUY HEATING & COOLING | H16 | C | 07/13/2015 | BY FINAL HAVE CLEAR ACCESS TO ATTIC FURNACE, FLEX BLOCKING ACCESS TO FURNACE AT ROUGH INSPECTION. | NANCY | NANCY | | H16 | C | 4991820 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HC | C | 07/13/2015 | OK TO SET METER. | NANCY | NANCY | | HC | C | 4991819 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 07/13/2015 | 10 LB TEST OK. 1 1/2 INCH LINE IN. 2 FURNACES (1 IN ATTIC), 2 WATER HEATERS, 1 RANGE, 1 FIREPLACE, 1 BBQ ( BACK DECK). | NANCY | NANCY | | HI | C | 4991814 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 07/09/2015 | Provide duct leakage report for attic system and equipment change letters, check for float switch at drain pan upper, check connections at wall/primary, and final venting at water heaters by final. Note: duct design, basement rough, AC rough both upper and lower, outside air to RA basement. | STEVEC | STEVEC | | HRR | C | 4989618 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 09/29/2015 | corrections made. | TAYLOR | TAYLOR | | P= | C | 5046293 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 09/25/2015 | install master tub, glass work being done in master shower ( could not check waters ), rest ok, pvb installed, unfinished basement. | TAYLOR | TAYLOR | | P= | P | 5044256 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 07/02/2015 | | DICK | DICK | | PTO | C | 4986097 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 04/16/2015 | | DICK | DICK | | PB | C | 4937288 |