HI-POINT HOME BUILDERS, LLC | B= | C | 05/18/2017 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 5510037 |
HI-POINT HOME BUILDERS, LLC | B= | P | 04/27/2017 | . Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 5489579 |
HI-POINT HOME BUILDERS, LLC | B= | P | 04/26/2017 | complete grading around house -- seal low volt wire exterior penetration at front of house -- landing at garage man door -- unfinished framed out basement/2nd story deck -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | SCOTTS | SCOTTS | | B= | P | 5487919 |
HI-POINT HOME BUILDERS, LLC | BLA | C | 11/28/2016 | | BOBF | BOBF | | BLA | C | 5354347 |
HI-POINT HOME BUILDERS, LLC | BIN | C | 08/10/2016 | | DAKOTAB | DAKOTAB | | BIN | C | 5266511 |
HOMEOWNER | BFR | C | 08/10/2016 | Items corrected | DAKOTAB | DAKOTAB | | BFR | C | 5266510 |
HI-POINT HOME BUILDERS, LLC | BSP | P | 08/10/2016 | eng letters for trusses, no repair required for either truss | BOBF | BOBF | | BSP | P | 5265564 |
HI-POINT HOME BUILDERS, LLC | BSP | P | 08/10/2016 | design on file | BOBF | BOBF | | BSP | P | 5265563 |
HI-POINT HOME BUILDERS, LLC | BFR | P | 07/25/2016 | OK to insulate -- Missing H2.5 on truss CJ, corners of shed roof -- Strap top plate in bedroom closet -- Stud at interior bearing wall behind door not secured -- Damaged top cord of truss N3 -- Damaged bottom cord on 3-ply truss G2 -- Missing gussets on truss T in kitchen -- Roll block joist below bearing wall at steel beam -- Need bearing block on glu-lam on rear deck | DAKOTAB | DAKOTAB | | BFR | P | 5253225 |
HI-POINT HOME BUILDERS, LLC | BSP | T | 07/12/2016 | PAID (REC#1341483) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised for new duct design and new calcs | JUSTINC | JUSTINC | | BSP | T | 5242917 |
HI-POINT HOME BUILDERS, LLC | BSP | P | 03/15/2016 | rear deck piers okay - (3) 15" piers / (1) 18" pier / (2) 27" piers / (1) 21" pier / open hole observation letter received | BRIANB | BRIANB | | BSP | P | 5155819 |
HI-POINT HOME BUILDERS, LLC | BSP | R | 03/14/2016 | need foundation design and stamped open hole to confirm pier sizes | BOBF | BOBF | | BSP | R | 5154616 |
HOMEOWNER | BSP | P | 02/16/2016 | 4 deck piers and 1 pad closest to house okay | BOBF | BOBF | | BSP | P | 5135238 |
HOMEOWNER | BFI | P | 10/09/2015 | complete bfn | DALE | DALE | | BFI | P | 5054736 |
HOMEOWNER | BFT | P | 10/09/2015 | ok per eng. / need foundation design | DALE | DALE | | BFT | P | 5054735 |
HOMEOWNER | BFN | P | 10/09/2015 | ok per eng. / need foundation design | DALE | DALE | | BFN | P | 5054728 |
HOMEOWNER | BFD | P | 10/09/2015 | need soils / drain is usable | DALE | DALE | | BFD | P | 5054727 |
HOMEOWNER | BFT | P | 10/07/2015 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 5052461 |
HOMEOWNER | BFN | P | 10/07/2015 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 5052460 |
WESTERN ELECTRIC | E= | C | 04/25/2017 | | CRAIG | CRAIG | | E= | C | 5486981 |
WESTERN ELECTRIC | E= | R | 04/24/2017 | remove pendant light above master tub, master toilet ex-fan not working, need more than 1 screw for industrial cover at disposal, ground switch for island lights, blank or install light in basement in room by sub-panel | MATTHEW | MATTHEW | | E= | R | 5485020 |
RENEW ELECTRIC COMPANY | E= | R | 03/21/2017 | gfi outside outlet at grade level ---------- install arc shield in mud room ---------- install inter system bonding terminal ----------- block mn cable in garage on top side ---------- blank off bath outlet in basement --------- 50 - amp A/C ok / Hot tub pre wire only / ------- install key less in basement ------- make up septic alarm --------- complete re inspect ---------------- note basement is framed out NO electric installed | CRAIG | CRAIG | | E= | R | 5451789 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 07/06/2016 | Residential Underground: 200 amp 3/w: new res meter is set: need seal | MATTHEW | MATTHEW | | ES | C | 5238718 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 07/06/2016 | | MATTHEW | MATTHEW | | ER | C | 5238685 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 07/05/2016 | see rough | MATTHEW | MATTHEW | | ES | R | 5237659 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | T | 07/05/2016 | PAID (REC#1339833): wires still laying on fireplace, master can light not installed, grounding electrode conductors have not been moved and main bonding jumper has not been installed | MATTHEW | MATTHEW | | ER | T | 5237651 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | R | 06/30/2016 | corrections not made | TOMC | TOMC | | ER | R | 5235075 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 06/30/2016 | Residential Underground: corrections not made | TOMC | TOMC | | ES | R | 5235073 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 06/24/2016 | see rough | MATTHEW | MATTHEW | | ES | R | 5231094 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | R | 06/24/2016 | stub out from controller to well head, install sub-panel (1/0al feeder laying on floor), install box for furnace disconnect, nm laying on fireplace and not landed in box, add outlet at handrail in foyer, install master bath can, land grounding electrode conductor on neutral bar or install main bonding jumper, neutrals doubled at service------------ basement framed but not wired, no mcc's, no vac, ufer connection in mech room ceiling; non-ir ufer, 1/0 al feeder to sub-panel location, 6-3nm stub for hot tub | MATTHEW | MATTHEW | | ER | R | 5231086 |
WINTERS ELECTRIC, INC. | EUG | C | 03/11/2016 | 3/w 250 mcm al service lateral | CRAIG | CRAIG | | EUG | C | 5153625 |
GENE'S HEATING AND AIR LLC | H= | C | 03/21/2017 | Notes-- unfinished basement. AC complete. | JEFFL | JEFFL | | H= | C | 5452024 |
GENE'S HEATING AND AIR LLC | HC | C | 07/18/2016 | RELEASE METER | MARK | MARK | | HC | C | 5247099 |
GENE'S HEATING AND AIR LLC | HRR | C | 07/18/2016 | Corrections made, rough ok. | MARK | MARK | | HRR | C | 5247094 |
GENE'S HEATING AND AIR LLC | HRR | P | 07/15/2016 | Need to complete B vent, undersized heat run on main lvl living rm, both bath vents on main level need to be replaced, water damaged. Note: Basement future. (Framed) 120K non direct vent matches. a/c coil and line set. 6" outside air. | MARK | MARK | | HRR | P | 5246005 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 07/12/2016 | 10 lb test ok. Note: 1 1/4 main fits with meter at house. Furnace, water heater, fireplace, range and future 3/4" stub at deck. | MARK | MARK | | HI | C | 5242596 |
HOMEOWNER | PWO | C | 04/24/2017 | ok.H20 sleeved through foundation. | CRADE | CRADE | | PWO | C | 5485406 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 04/24/2017 | Corrections made. | CRADE | CRADE | | P= | C | 5485378 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 04/21/2017 | Need to check for pwo inspection.Rest ok. | CRADE | CRADE | | P= | P | 5483378 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 04/12/2017 | certificate of potable water scanning. | JOHNS | JOHNS | | P= | P | 5472266 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 04/11/2017 | lav not set in powder room, secure front hose bib, rest OK, Note: Basement rough-in only Note: Need potable water certificate for final | SHANEN | SHANEN | | P= | P | 5471951 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 07/13/2016 | correction made, basement bathroom to be rough only | TED | TED | | PTO | C | 5244319 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | P | 07/12/2016 | LOST TEST IN MASTER , CHECK GRADE ON LAV WASTE IN GUEST ON MAIN LEVEL ,SET TUB IN BASEMENT , REST OK , NOTE FINISHED BASEMENT , NO IRRIGATION , VTR AT BAR | GABE | GABE | | PTO | P | 5243003 |
JOEAGLE PLUMBING & HEATING, INC. | PB | C | 12/10/2015 | NO WATER IN , | GABE | GABE | | PB | C | 5096568 |