PEAK PROFESSIONAL CONTRS INC | B= | C | 04/29/2016 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 5187538 |
PEAK PROFESSIONAL CONTRS INC | B= | P | 04/06/2016 | address numbers posted. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | P | 5171055 |
PEAK PROFESSIONAL CONTRS INC | B= | P | 04/05/2016 | Post address on front of building / eng letter fror structural steel, including bar joists, cross bracing, metal decking and connections including welding on file / confirmed R value of insulation is R-17.2 for 3" rigid insulation -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | BOBF | BOBF | | B= | P | 5169549 |
PEAK PROFESSIONAL CONTRS INC | BIN | P | 03/16/2016 | all exterior wall insulation OK / still need information for roof insulation to verify R value | DANE | DANE | | BIN | P | 5156266 |
PEAK PROFESSIONAL CONTRS INC | BFR | P | 03/16/2016 | still need roof insulation paperwork to verify R value / still need welding and bolting inspection letters / wall under beam down to storefront framing OK / this concludes all framing but still need all letters / still need all other MEP inspections | DANE | DANE | | BFR | P | 5156254 |
PEAK PROFESSIONAL CONTRS INC | BIN | R | 03/02/2016 | need paper work of ridged insulation for roof to confirm R value is = to or greater than R17 | DANE | DANE | | BIN | R | 5146292 |
PEAK PROFESSIONAL CONTRS INC | BFR | P | 03/02/2016 | north exterior wall at addition OK pending other inspections / remainder of demising walls OK pending other roughs / still need to attach electric inspection / need 3rd party inspection letter for welding and bolting / still need to inspect exterior wall at existing unit and at rear of addition | DANE | DANE | | BFR | P | 5146291 |
PEAK PROFESSIONAL CONTRS INC | BSP | T | 02/23/2016 | PAID (REC#1314573) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: removed (2) Uh's from core and shell space | JUSTINC | JUSTINC | | BSP | T | 5140441 |
PEAK PROFESSIONAL CONTRS INC | BSP | P | 02/23/2016 | PLAN SPLICE: (No Fee) by: BRIAN for Electrical | BRIAN | BRIAN | | BSP | P | 5140363 |
PEAK PROFESSIONAL CONTRS INC | BBB | P | 02/18/2016 | bond beams at top of walls OK | DANE | DANE | | BBB | P | 5137174 |
PEAK PROFESSIONAL CONTRS INC | BFR | P | 02/16/2016 | framing of new demising walls OK pending other rough inspections / need to attach mechanical and electric permits / bathrooms existing and not conforming | DANE | DANE | | BFR | P | 5134500 |
PEAK PROFESSIONAL CONTRS INC | BBB | P | 02/16/2016 | bond beam at north south running wall at 24th course OK | DANE | DANE | | BBB | P | 5134484 |
PEAK PROFESSIONAL CONTRS INC | BBB | P | 02/11/2016 | bond beam at roof line OK at grid line 4.5 and between H and A1 (east west wall) | DANE | DANE | | BBB | P | 5132558 |
PEAK PROFESSIONAL CONTRS INC | BFN | C | 02/04/2016 | reinforcement for concrete columns OK | DANE | DANE | | BFN | C | 5128225 |
PEAK PROFESSIONAL CONTRS INC | BFN | P | 01/29/2016 | perimeter foundation and foundation insulation at east side OK / still need to inspect concrete columns | DANE | DANE | | BFN | P | 5126137 |
PEAK PROFESSIONAL CONTRS INC | BFT | R | 01/27/2016 | not ready - no steel in hole / need stamped copy of open hole and rebar schedule for footing inspection | DANE | DANE | | BFT | R | 5124307 |
SCHEINER COMMERCIAL GROUP, INC. | BSP | T | 12/02/2015 | PAID (REC#1302036) PLAN SPLICE FEE: $50 by: DOUG for Electrical: revised to minimal work | DOUG | DOUG | | BSP | T | 5090339 |
SCHEINER COMMERCIAL GROUP, INC. | BSP | P | 11/06/2015 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: no new mecanical | JUSTINC | JUSTINC | | BSP | P | 5074924 |
SCHEINER COMMERCIAL GROUP, INC. | BSP | T | 11/06/2015 | PAID (REC#1298018) PLAN SPLICE FEE: $50 by: DOUG for Electrical: New title block for new architect | DOUG | DOUG | | BSP | T | 5074896 |
EL PASO ELECTRIC, LLC. | E= | C | 03/22/2016 | | BRET | BRET | | E= | C | 5160813 |
EL PASO ELECTRIC, LLC. | ER | C | 03/22/2016 | | BRET | BRET | | ER | C | 5160812 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | C | 04/04/2016 | | NANCY | NANCY | | H= | C | 5169159 |
ARTISAN PIPE SYSTEMS, INC. | P= | C | 03/21/2016 | CORE SHELL ONLY | GABE | GABE | | P= | C | 5159583 |
ARTISAN PIPE SYSTEMS, INC. | PB | C | 01/21/2016 | NOTE , THIS UNIT IS NEXT DOOR TO THE POTTERY BARN TO THE WEST , MAIN TRUNK AND RISER , | GABE | GABE | | PB | C | 5120840 |