HOMEOWNER | B= | C | 09/20/2018 | Covered rear deck with stairs - Unfinished basement with finished bathroom - AC installed | TIMOTHYS | TIMOTHYS | | B= | C | 5972024 |
HOMEOWNER | BIN | C | 07/10/2018 | | LONNYS | LONNYS | | BIN | C | 5898328 |
HOMEOWNER | BFR | C | 07/10/2018 | received engineer letter for master bath header and G01 girder / all other framing items corrected | LONNYS | LONNYS | | BFR | C | 5898304 |
HOMEOWNER | BFR | P | 07/05/2018 | OK to insulate as long as items can be seen -- Fireblock garage door brackets in both garages -- Kickers from strongbacks on both gable ends not at 48" OC -- Plans don't show header over 100" for window in master bedroom -- Missing 3rd header at master bedroom window -- TBE installed incorrectly at G01 -- Missing H2.5's at T07 and T07A end bearing in side garage -- Nail off TBE at side garage common wall -- Shim hanger at girder at side garage -- Remove wood shims from beam pocket in basement -- Window at rear basement wall calls for (3) Trimmers and (3) kings each end -- Remove float blocks at basement stairs -- Nail off post base for rear porch post -- Fill and nail of rear side of EPC6 at middle post of deck -- Missing hardware at corners of deck | DAKOTAB | DAKOTAB | | BFR | P | 5894056 |
HOMEOWNER | BLA | C | 07/02/2018 | | LONNYS | LONNYS | | BLA | C | 5891015 |
HOMEOWNER | BSP | P | 06/11/2018 | basement boiler room framing and insulation OK | LONNYS | LONNYS | | BSP | P | 5870844 |
HOMEOWNER | BSP | P | 06/11/2018 | rear deck cover lid OK / still need to inspect deck | LONNYS | LONNYS | | BSP | P | 5870825 |
HOMEOWNER | BFD | C | 06/11/2018 | all paperwork on file | LONNYS | LONNYS | | BFD | C | 5870814 |
HOMEOWNER | BSP | R | 06/07/2018 | rear deck cover lid missing 2nd H2.5 EE of all trusses / front porch lid OK / NOTE: still need to inspect deck framing | LONNYS | LONNYS | | BSP | R | 5867690 |
HOMEOWNER | BSP | P | 05/07/2018 | 3 new rear deck piers OK | LONNYS | LONNYS | | BSP | P | 5837218 |
HOMEOWNER | BFN | C | 05/02/2018 | Engineer letter for foundation received -- Eufer noted -- Foundation design received(Bearing capacity verified) | DAKOTAB | DAKOTAB | | BFN | C | 5833251 |
HOMEOWNER | BFT | C | 05/02/2018 | Engineer letter for footing received -- Open hole received -- 1500 PSF - Drain usable - 10% | DAKOTAB | DAKOTAB | | BFT | C | 5833250 |
HOMEOWNER | BFI | C | 04/27/2018 | 2" foam insulation OK -- UPDATED 5/2 8:50am - 3" foundation insulation is installed | DAKOTAB | DAKOTAB | | BFI | C | 5829618 |
HOMEOWNER | BFD | R | 04/27/2018 | Need open hole and foundation engineering -- Drain is usable and daylights at southwest corner of foundation - Damp proofing OK | DAKOTAB | DAKOTAB | | BFD | R | 5829597 |
CL SHARPER ELECTRIC | E= | C | 09/19/2018 | 30 amp a/c | TOMC | TOMC | | E= | C | 5969791 |
CL SHARPER ELECTRIC | ES | C | 07/03/2018 | Completed ES inspection on 7.2.2018--Meter needs seal / | ROB | ROB | | ES | C | 5893273 |
CL SHARPER ELECTRIC | ER | C | 07/03/2018 | Correction complete / | ROB | ROB | | ER | C | 5893264 |
CL SHARPER ELECTRIC | ES | C | 07/02/2018 | 200 amp ug res new No action required------------100 amp sub panel ok-------------/ | ROB | ROB | | ES | C | 5891899 |
HOMEOWNER | ER | R | 07/02/2018 | Need listed clamp and plaster ring--Ok to upload pic--- #6 AL to cooktop / #6 AL to oven/range / 10-2 CU to A/C / 8-2 CU to Steamer / 6-3CU to Kiln / 10-3 CU to well / No mcc's / Finished Basement / Partial crawler / Cent Vac installed / | ROB | ROB | | ER | R | 5891898 |
CL SHARPER ELECTRIC | EUG | P | 05/11/2018 | EUG from meter pedestal to house ok to cover / | ROB | ROB | | EUG | P | 5842663 |
THE FURNACE GUY HEATING & COOLING | H= | C | 09/06/2018 | DUCT LEAKAGE REPORT RECEIVED AND SENT SCANNING. NOTE: DIRECT VENT BOILER WITH STORAGE TANK FOR HOT WATER, IN FLOOR RADIANT HEAT, AIR HANDLER IN ATTIC FOR COOLING ONLY. | DUSTINS | DUSTINS | | H= | C | 5957076 |
J D PLUMBING AND HEATING LLC | HWP | C | 07/03/2018 | 60 LB TEST OK ON MAIN LEVEL, OK TO COVER. | DUSTINS | DUSTINS | | HWP | C | 5892659 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 06/22/2018 | NEED DUCT LEAKAGE REPORT BY FINAL FOR AIR HANDLER IN ATTIC. NOTE: DIRECT VENT BOILER WITH STORAGE TANK FOR HOT WATER, IN FLOOR RADIANT HEAT, AIR HANDLER IN ATTIC FOR COOLING ONLY. | DUSTINS | DUSTINS | | HRR | C | 5883221 |
J D PLUMBING AND HEATING LLC | HC | C | 06/21/2018 | RELEASE METER | DUSTINS | DUSTINS | | HC | C | 5881825 |
J D PLUMBING AND HEATING LLC | HI | C | 06/21/2018 | 10 LB TEST OK. 1 1/4" MAIN. 1- BOILER, 1- COOK TOP, 1- BBQ, 1- DRYER, 1- FIREPLACE. | DUSTINS | DUSTINS | | HI | C | 5881821 |
J D PLUMBING AND HEATING LLC | HWP | P | 06/07/2018 | 60 lb test ok in garage. OK to cover. | JEFFL | JEFFL | | HWP | P | 5867291 |
J D PLUMBING AND HEATING LLC | HWP | P | 05/07/2018 | 60 lb test ok for basement. Basement ok to cover. | JEFFL | JEFFL | | HWP | P | 5837266 |
J D PLUMBING AND HEATING LLC | P= | C | 09/19/2018 | finished basement, RP installed at mech room, note: certificate of potable water sent to scanning. | TAYLOR | TAYLOR | | P= | C | 5969461 |
J D PLUMBING AND HEATING LLC | PTO | C | 06/20/2018 | finished basement, aav's at both sinks in kitchen, laundry sink, utility sink in garage, check steam generator by final. | TAYLOR | TAYLOR | | PTO | C | 5879799 |
J D PLUMBING AND HEATING LLC | PWO | C | 05/10/2018 | Ok, potable water cert by final. | DANR | DANR | | PWO | C | 5841070 |
J D PLUMBING AND HEATING LLC | PB | C | 05/02/2018 | | SHANEN | SHANEN | | PB | C | 5834120 |