ASPEN VALLEY CUSTOM HOMES, LLC | B= | C | 06/07/2019 | All other required Final inspections are complete. (This is a computer generated result) | NATHAN | NATHAN | | B= | C | 6224529 |
ASPEN VALLEY CUSTOM HOMES, LLC | B= | P | 05/24/2019 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NATHAN | NATHAN | | B= | P | 6210848 |
ASPEN VALLEY CUSTOM HOMES, LLC | BLA | C | 11/07/2018 | | NATHAN | NATHAN | | BLA | C | 6019285 |
ASPEN VALLEY CUSTOM HOMES, LLC | BIN | C | 10/24/2018 | Crawlspace area can be checked at final. ES report and installation thickness on file | NATHAN | NATHAN | | BIN | C | 6004025 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFR | C | 10/23/2018 | window frame completed letter on file | NATHAN | NATHAN | | BFR | C | 6002695 |
ASPEN VALLEY CUSTOM HOMES, LLC | BIN | P | 10/22/2018 | BIN inspection / R13 batt insulation installed in the exterior walls of the garage and portions of basement with blanket installed on crawl space mass walls only. Remaining insulation for walls, underside of roof sheathing in attic and rim joist in crawl space is spray applied foam insulation and will need a certificate of compliance noting R-value from the insulation installer. / Provide documentation that attic and crawl space rim has an ignition barrier installed per R316.5.3/.4 of the 2009 IRC or was installed as a tested assembly per R316.6. | CHUCK | CHUCK | | BIN | P | 6001776 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFR | P | 10/15/2018 | need header at bedroom addressed still, remaining items corrected, truss fix on file | NATHAN | NATHAN | | BFR | P | 5995169 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFR | P | 10/15/2018 | front porch vault framing | NATHAN | NATHAN | | BFR | P | 5994085 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFN | C | 10/15/2018 | foundation plan on file | NATHAN | NATHAN | | BFN | C | 5994082 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | R | 10/12/2018 | inspection was called in to upload foundation plan but image was not attached. | NATHAN | NATHAN | | BSP | R | 5992853 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFR | R | 10/10/2018 | post down 2 studs at T12G garage door also 2 truss clips needed, cap bottom of garage cantilever, missing nails in HUS26 hangers over powder bath to garage, missing truss gusset at JO1 over master shower wall in hanger, missing 1 bearing block at TO4G entry side, need repair at T10 TRUSS broken webs and gussets, dry in all roof penetrations, address windows in basement with no header call out, secure base of monopost at all crawlspace beams, need foundation plan. | NATHAN | NATHAN | | BFR | R | 5991418 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | P | 08/17/2018 | front porch, posts, rear deck posts, deck and roof frame okay | NATHAN | NATHAN | | BSP | P | 5938079 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | P | 08/15/2018 | rear deck columns okay | NATHAN | NATHAN | | BSP | P | 5935511 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFN | C | 06/21/2018 | Engineers observation Letter on file / Eufer OK / Foundation design on file / | NATHAN | NATHAN | | BFN | C | 5881133 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFT | C | 06/21/2018 | Engineers observation Letter on file / | NATHAN | NATHAN | | BFT | C | 5881132 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | C | 06/14/2018 | frame of structural floor okay | NATHAN | NATHAN | | BSP | C | 5875061 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFI | C | 06/14/2018 | | NATHAN | NATHAN | | BFI | C | 5875054 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFD | C | 06/12/2018 | drain is usable to daylight at east side. | NATHAN | NATHAN | | BFD | C | 5871979 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFI | P | 06/12/2018 | provide ES report for foam insulation at rim around structural floor. | NATHAN | NATHAN | | BFI | P | 5871969 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | R | 06/12/2018 | structural floor rim attachment to foundation and joist hangers are covered by foam insulation and cannot be seen. | NATHAN | NATHAN | | BSP | R | 5871885 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | P | 06/12/2018 | structural floor frame image attached | NATHAN | NATHAN | | BSP | P | 5871221 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFN | R | 06/12/2018 | wrong image attached | NATHAN | NATHAN | | BFN | R | 5871218 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFT | R | 06/12/2018 | drilled pier installation observation wrong | NATHAN | NATHAN | | BFT | R | 5871188 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFI | R | 06/08/2018 | Need gate code for inspection. | PARKER | PARKER | | BFI | R | 5869571 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFD | R | 06/07/2018 | no gate code, no one present to grant access. | NATHAN | NATHAN | | BFD | R | 5867890 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFD | P | 06/07/2018 | soils attached | NATHAN | NATHAN | | BFD | P | 5867267 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFN | R | 06/07/2018 | contact Jeremy Anderson, foundation observation letter attached. | NATHAN | NATHAN | | BFN | R | 5867262 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFT | R | 06/07/2018 | drilled pier log attached. | NATHAN | NATHAN | | BFT | R | 5867260 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFT | P | 05/25/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5855803 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFN | P | 05/25/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5855802 |
ALL WIRE ELECTRIC | E= | C | 05/24/2019 | FA permit pulled / M29873 | MIGUEL | MIGUEL | | E= | C | 6209489 |
ALL WIRE ELECTRIC | E= | R | 04/26/2019 | need FA permit pulled and contractor to meet on site or pull devices / 125A sub panel ok / 40A steamer / 50A hot tub pre-wire / A/C pre-wire x2 / can close electrical after FA permit pulled / | MIGUEL | MIGUEL | | E= | R | 6179974 |
ALL WIRE ELECTRIC | ES | C | 09/17/2018 | Residential Underground: 200A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 5967719 |
ALL WIRE ELECTRIC | ER | C | 09/17/2018 | non IR connection, finished basement, LV central vac, #6 AL x2, 1/0 AL to sub panel, 1-10/3 CU, floor heat in master bath, floor box----sub panel---hot tub stub / | MIGUEL | MIGUEL | | ER | C | 5967718 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 04/25/2019 | BOTH OF THE OUTSIDE AIR DUCTS MEET THE MAKE-UP AIR REQUIREMENT FOR THE RANGE HOOD. | MATTM | MATTM | | H= | C | 6177765 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 04/25/2019 | RECEIVED IMAGE OF HI/LO TRANSFERS, SEE IMAGES. | MATTM | MATTM | | H= | P | 6177545 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 04/24/2019 | 1200CFM RANGE HOOD WILL REQUIRE INTERLOCKED MAKE-UP AIR, SEAL ALL GORES ON RANGE EXHAUST DUCT, LOW TRANSFER GRILLE TO MECHANICAL ROOM WILL BE BLOCKED BY REFRIGERATOR WHEN INSTALLED | MATTM | MATTM | | H= | P | 6176710 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 04/22/2019 | MISSING STORM COLLAR ON B-VENT, COMMON VENT LACKS 1" CLEARANCE TO SPRAY FOAM IN MECHANICAL ROOM, MECHANICAL ROOM LACKS COMBUSTION AIR, INSTALL GAS PIPE GROMMET ON BOTH FURNACES PER MANUFACTURES INSTALLATION INSTRUCTIONS PAGE 17, 60K BTU FURNACE VENT NEEDS TO BE SUPPORTED EVERY 3FT IN MECHANICAL ROOM PER PAGE 37 OF THE INSTALLATION INSTRUCTIONS, SEAL ALL GORES ON RANGE EXHAUST DUCT, RANGE EXHAUST DUCT IS MISSING BACKDRAFT DAMPER, PROVIDE KITCHEN RANGE HOOD CFM AND INSTALLATION INSTRUCTIONS NOTES: FINISHED BASEMENT, CONDITIONED CRAWLSPACE (3 SUPPLY 1 RETURN), 2X OUTSIDE AIR TO FURNACE RETURN, 2X INDIRECT VENT FURNACE, 1X A/C ROUGH COIL, 2X A/C ROUGH LINESET, 1 FIREPLACE | MATTM | MATTM | | H= | P | 6173684 |
WINTERROWD ENTERPRISES, INC | HC | C | 10/09/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 5990450 |
WINTERROWD ENTERPRISES, INC | HI | C | 10/09/2018 | 10# test ok. note: 2" main at 120' to 2- furnaces, 2- water heaters, 1- fire place, 1- fire pit and 1- range. | PAULO | PAULO | | HI | C | 5990447 |
WINTERROWD ENTERPRISES, INC | HI | R | 10/03/2018 | All CSST is measured back to the regulator. 1/2" csst does not fit chart for both water heaters and 60K furnace. 3/4" csst will only carry 71K BTU to patio fire feature, 3/4" csst to range will use all available capactiy so there won't be any left for lower level patio stub. fireplace on main level is also undersized for capacity. See Trackpipe chart and size all branches to the regulator. Note: 2" main. test is void. | MARK | MARK | | HI | R | 5984402 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 09/27/2018 | Corrections made. | MARK | MARK | | HRR | C | 5978218 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 09/26/2018 | Trip fee waived please attach pictures of corrections to permit to avoid 3rd trip. Still have clearance issues at B vent to roofing materials and same for fireplace vent, Header missing for return in floor bay in basement soffit. (Next to other return header. By final make up air to laundry and storm collar on B vent.
| MARK | MARK | | HRR | P | 5977338 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 09/20/2018 | Duct design does not match. Need to re splice or submit for plan revision. Missing 3- 5" heat runs in basement closets/storage area, 8" heat runs were used in rec room and great room, plans call for 7" Missing one 7" in both those rooms. Kitchen exhaust does not go through roof, B vent touching roofing material, fireplace requires non combustible material where wood was used see pg 25 of F/P install instructions also vent is touching wood roof deck and roofing. Missing return header in basement above soffit between mechanical room and rec room. Stopped inspection. Note: At re inspection, check equipment to equipment schedule and check vent lenghts. has 1 A/C, 2- osa 2- non direct vent furnaces. Basement is finished, crawl space supplies and return ok | MARK | MARK | | HRR | P | 5971707 |
BEACON PLUMBING, LLC | P= | C | 04/29/2019 | correction made note: RP for irrigation in basement | JOSEPHD | JOSEPHD | | P= | C | 6180732 |
BEACON PLUMBING, LLC | P= | P | 04/24/2019 | need to run drain for RP to floor drain, other correction made | JOSEPHD | JOSEPHD | | P= | P | 6176322 |
BEACON PLUMBING, LLC | P= | P | 04/19/2019 | need backflow for irrigation installed, need to caulk floor drain on wood floor in basement, rest ok note: finished basement | JOSEPHD | JOSEPHD | | P= | P | 6171267 |
BEACON PLUMBING, LLC | PTO | C | 09/14/2018 | ok for all upr floor dwv / water. NOTE: crawl space, vtr (3), aav @ both kitchen sinks, bar, and north bsmnt lav, irrigation stub, rp @ mech by final, tempering @ water htr by final, check steamer @ mstr bath closet attic @ final, (attic is conditioned space) **still need crawl space and mech quad drain inspected **UPDATED NOTES 10/10/18 AS FOLLOWS- COMPLETED PTO FOR GC TO GET BLDG INSPECTION, PLBG CONTRACTOR WILL CALL FOR A P= TO INSPECT CRAWL SPACE PLBG ONCE AREA DRIES OUT | JOHNS | JOHNS | | PTO | C | 5965511 |
ASPEN VALLEY CUSTOM HOMES, LLC | XMS | T | 09/25/2018 | PAID (REC#1550812): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: changes to duct design | DALEH | DALEH | | XMS | T | 5975496 |
ASPEN VALLEY CUSTOM HOMES, LLC | XMS | T | 09/18/2018 | PAID (REC#1540782) PLAN SPLICE FEE: $50 by: DALEH for Mechanical | DALEH | DALEH | | XMS | T | 5968815 |
ASPEN VALLEY CUSTOM HOMES, LLC | XBS | T | 08/30/2018 | PAID (REC#1540782) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Structural basement floor | MICHAELA | MICHAELA | | XBS | T | 5950461 |
ASPEN VALLEY CUSTOM HOMES, LLC | XBS | P | 06/13/2018 | PLAN SPLICE: (No Fee) by: MICHAELA for Construction: Add structural floor | MICHAELA | MICHAELA | | XBS | P | 5873681 |