HOMEOWNER | BIN | P | 03/28/2023 | Check attic at final | PAULP | PAULP | | BIN | P | 7700567 |
HOMEOWNER | BFR | C | 03/17/2023 | Splice complete | PAULP | PAULP | | BFR | C | 7690200 |
HOMEOWNER | BFR | P | 03/16/2023 | Pending approved plan splice for headers and windows / | ANGELW | ANGELW | | BFR | P | 7689369 |
HOMEOWNER | BFR | R | 03/10/2023 | Missing king studs master bedroom north window /Windows added upper west bed and hall need window header schedules / clarification on trimmers and kings on kitchen sliding glass header/ trimmers in headers not bearing throughout glue and shim | PAULP | PAULP | | BFR | R | 7684549 |
HOMEOWNER | BFR | R | 03/09/2023 | Met with homeowner to review all items / Stilll need Foundation observation from RMG footing is on file / Incorrect fasteners in Simpson Tie hardware garage and master bedroom THJA's / missing shear nailing in J07 trusses onto T05G / updated details for T05 trusses in garage - on site do not match nomenclature in details / missing H2.5's on T05's above garage beam / T01A broken above master bedroom at web 4-9 / Bracing on T01's webs 5-7 / Missing west windows and header schedule/ Stopped inspection after all trusses / Need to recall BFR for rest | PAULP | PAULP | | BFR | R | 7683066 |
HOMEOWNER | BFR | R | 03/08/2023 | Spoke with owner will recall BFR once splice has been approved for new changes and trusses | PAULP | PAULP | | BFR | R | 7680958 |
HOMEOWNER | BFR | P | 03/07/2023 | Engineer Stamped Structural revisions on file / Need to update plan on permit through PPRBD Plan Review with these documents /
Prior to next site visit need updated truss layout for as built condition
Contact inspector for any questions | PAULP | PAULP | | BFR | P | 7678365 |
HOMEOWNER | BSP | R | 01/12/2023 | changed to BSP from BFR too many items / met with homeowner reviewed need to provide updated plan to show as built conditions prior to next inspection request | PAULP | PAULP | | BSP | R | 7633225 |
HOMEOWNER | BTR | C | 03/26/2021 | Battens, flashing, and underlayment ok. / | PAULP | PAULP | | BTR | C | 6912174 |
HOMEOWNER | BSP | P | 03/12/2021 | Stucco ok / advised homeowner will need to be inspected at final as well | PAULP | PAULP | | BSP | P | 6898261 |
HOMEOWNER | BLA | C | 02/23/2021 | | PAULP | PAULP | | BLA | C | 6878038 |
HOMEOWNER | BFN | C | 01/12/2021 | Dampproofing complete from drain inspection | PAULP | PAULP | | BFN | C | 6832935 |
HOMEOWNER | BSP | P | 12/18/2020 | Need to complete foundation inspections/ Need updated truss design / Inspection changed from BFR to BSP for front porch frame and cover only / porch ok | PAULP | PAULP | | BSP | P | 6812922 |
HOMEOWNER | BIN | P | 12/17/2020 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | MATTHEW | MATTHEW | | BIN | P | 6810566 |
HOMEOWNER | BFD | P | 05/08/2020 | Need to complete BFN | ASHLEYB | ASHLEYB | | BFD | P | 6566097 |
HOMEOWNER | BFD | P | 05/07/2020 | Damp proofing incomplete - Drain installed entire - Daylights SE corner | ASHLEYB | ASHLEYB | | BFD | P | 6564297 |
HOMEOWNER | BFN | P | 05/06/2020 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 6563247 |
HOMEOWNER | BFT | C | 04/23/2020 | footer and open excavation letters on file, drain usable, interior float, final grade 10% | NATHAN | NATHAN | | BFT | C | 6550180 |
HOMEOWNER | BFT | R | 03/31/2020 | Not ready | ASHLEYB | ASHLEYB | | BFT | R | 6526736 |
HOMEOWNER | BE | L | 10/31/2019 | Renewed for $391.00 at 10/31/2019 8:32:00 AM (Receipt#1641116) | GITA | GITA | | BE | L | 6384290 |
HOMEOWNER | BE | P | 04/25/2019 | | MATTHEWM | MATTHEWM | | BE | P | 6177820 |
HOMEOWNER | BE | C | 11/08/2018 | | TERRI | TERRI | | BE | C | 6020203 |
HOMEOWNER | E= | R | 03/07/2024 | discussed all corrections w/ homeowner / complete re-inspect / need to install AFCI/ GFCI where required / install WR receptacles on exterior w/ in-use covers just to name a couple of issues / smokes installed / bond wire for jet tub installed /exhaust fan listed , needs required protection / | MIGUEL | MIGUEL | | E= | R | 8017172 |
HOMEOWNER | E= | R | 09/20/2023 | not ready / complete reinspection / need #8 to jet tub motor / need paper work on fan inside the shower or remove / need gfci / afci breaker for washer / laundry room has reverse polarity / missing smokes / enclosed lights in closets / shower trims for showers / stopped inspection / | BRIAN | BRIAN | | E= | R | 7862601 |
HOMEOWNER | ER | C | 01/09/2023 | check for proper IR connection on water GEC on final at water meter / rest of corrections made / | MIGUEL | MIGUEL | | ER | C | 7629688 |
HOMEOWNER | ER | R | 11/15/2022 | still need to verify black tubing / install ground screws on metal j-boxes / add outlets slider within 6' of fixed glass panel / install nail plates where required / can not have dishwasher outlet behind equipment /need to install water GEC / unfinished basement / reversible ufer / | MIGUEL | MIGUEL | | ER | R | 7583644 |
HOMEOWNER | E16 | C | 08/16/2022 | need specs on tubing, will need proper connectors for tubing into boxes w/ KOs / install stackers for cables to meet clearances / | MIGUEL | MIGUEL | | E16 | C | 7484503 |
HOMEOWNER | E16 | P | 12/29/2020 | Discussed AFCI/GFCI/TR requirements with owner. / discussed basic branch circuit requirements / | MIGUEL | MIGUEL | | E16 | P | 6820954 |
HOMEOWNER | ES | C | 10/01/2020 | Residential Underground: 200A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 6726955 |
HOMEOWNER | ES | R | 09/28/2020 | 200A / install bond screw and #4 CU to ufer / need to dry in panel still / was told roof construction was in 3 weeks / | MIGUEL | MIGUEL | | ES | R | 6721722 |
HOMEOWNER | ES | R | 09/10/2020 | need to remove panel and fully enclose and weather tight structure / install hub cover on top of meter can / need to verify the use of sch 80 PVC in structure / | MIGUEL | MIGUEL | | ES | R | 6701680 |
HOMEOWNER | HC | C | 12/01/2021 | RELEASE METER | MICHAELM | MICHAELM | | HC | C | 7193130 |
HOMEOWNER | HRR | C | 12/01/2021 | CORRECTION MADE / SEE IMAGES | MICHAELM | MICHAELM | | HRR | C | 7193126 |
HOMEOWNER | HRR | P | 11/30/2021 | REMOVE TAPE FROM ATTIC FURNACE B-VENT / OK TO ATTACH PICTURE OF CORRECTION TO AN INSPECTION REQUEST / Upon further review; the IECC/IRC Ventilation Verification form not needed for 2011 code / | MICHAELM | MICHAELM | | HRR | P | 7191971 |
HOMEOWNER | HRR | P | 11/23/2021 | *** By final; need to update the HVAC Equipment Certificate; IECC/IRC Ventilation Verification for all fans ( Need to research if needed for the 2011 code) *** / COMPLETE FRAMING AROUND WATER HEATER B-VENT ON UPPER FLOOR / REMOVE ALL TAPE FROM FURNACE AND WATER HEATER B-VENTS / COMPLETE RANGE HOOD DUCT IN SMOOTH WALL / ****80% furnace in attic**** / NO WHOLE HOUSE FAN ( Need to research for 2011 code) / NOTE: UNFINISHED BASEMENT WITH 6 SUPPLIES AND 4 RETURNS / DIRECT VENT FURNACE IN BASEMENT / NO OUTSIDE AIR / HIGH/LOW COMBUSTION AIR / A/C ROUGH, COIL ONLY X 2 / | MICHAELM | MICHAELM | | HRR | P | 7187120 |
HOMEOWNER | HI | C | 08/19/2021 | 10 LB TEST OK / RE-SIZED TO 3/4 INCH FOR FURNACE AND BBQ | MICHAELM | MICHAELM | | HI | C | 7077904 |
HOMEOWNER | HI | P | 08/12/2021 | 1/2 INCH BLACK PIPE TO 100K FURNACE IN BASEMENT IS UNDERSIZED AT 72 FEET FROM METER / 1/2 INCH BLACK PIPE FOR FUTURE 50K BBQ IS UNDERSIZED AT 136 FEET FROM METER / NEED TO HAVE UNDER TEST AGAIN AFTER CORRECTIONS / 10 LB TEST OK / 1 1/4 INCH MAIN / 2 FURNACE / 2 WATER HEATER / 1 COOKTOP / 1 FIREPLACE / 1 BBQ / | MICHAELM | MICHAELM | | HI | P | 7070106 |
HOMEOWNER | HV | C | 08/12/2021 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK | MICHAELM | MICHAELM | | HV | C | 7070098 |
HOMEOWNER | HV | P | 08/10/2021 | CHANGED TO AN HV INSPECTION. FIREPLACE VENT LACKS CLEARANCE TO PLYWOOD AT ROOF LINE ON THE DOWN HILL SIDE. HOMEOWNER TO ATTACH PICTURES AT NEXT INSPECTION REQUEST. | BILLS | BILLS | | HV | P | 7066450 |
HOMEOWNER | PTO | C | 06/27/2022 | Corrections Made | TRAVISR | TRAVISR | | PTO | C | 7426651 |
HOMEOWNER | PTO | P | 06/22/2022 | WAIVE TRIP FEE / STILL NEED INSULATION ON 3/4 & 1" HOT WATER LINES & STRAP DWV & H20 PROPERLY | TRAVISR | TRAVISR | | PTO | P | 7421256 |
HOMEOWNER | PTO | P | 06/20/2022 | Need To Insulate Hot 1' & 3/4 Hot Lines / Secure Toilet Flanges Throughout / Kitchen DWV Lacks Grade Through Out / S-Traps @ Master Tub & Bathroom Over Garage / Dry Vent @ Main Level Shower San Tee Facing Wrong Direction Of Flow / Strapping & Grading Issues Through Out / No Hose Bibs @ Time Of Inspection /
No Tubs @ Time Of Top Out / Back Order / Need Mixing Valve For Master Tub By Final Note: Unfinished Basement / Irrigation Stub / 3-VTR | TRAVISR | TRAVISR | | PTO | P | 7417790 |
HOMEOWNER | PTO | P | 05/24/2022 | NEED TO RE-INSPECT ALL
HAVE GRADING, STRAPPING, VENTING, & SIZING ISSUES THROUGH OUT / HORIZONTAL DRY VENTS CAN NOT BE USED / NEED TO USE CORRECT PVC GLUE & PRIMER / COLD WATER UNDERSIZED / CAN NOT USE SAN TEE'S ON THERE SIDE / SAN TEES WRONG DIRECTION OF FLOW / NEED NAIL PROTECTION THROUGH OUT / NEED TO COMPLETE TUB-SHOWER VALVES | TRAVISR | TRAVISR | | PTO | P | 7386853 |
HOMEOWNER | PB | C | 08/07/2020 | | SAMH | SAMH | | PB | C | 6665684 |
HOMEOWNER | PB | P | 08/04/2020 | Need approved p-traps at showers. Test dwv piping. | SAMH | SAMH | | PB | P | 6660926 |
HOMEOWNER | XBS | T | 03/16/2023 | PAID (REC#1940351) PLAN SPLICE FEE: $50 by: DANM for Construction: Structural revisions, structural detail, missing truss | DANM | DANM | | XBS | T | 7689602 |
HOMEOWNER | XBS | T | 03/08/2023 | PAID (REC#1938193) PLAN SPLICE FEE: $50 by: DANM for Construction: Structural framing revisions | DANM | DANM | | XBS | T | 7681088 |