DOUBLE DIAMOND ENTERPRISES, INC | B= | C | 11/25/2019 | | NICK | NICK | | B= | C | 6409703 |
DOUBLE DIAMOND ENTERPRISES, INC | BSP | P | 11/25/2019 | ES report for spray foam on file | NICK | NICK | | BSP | P | 6409279 |
DOUBLE DIAMOND ENTERPRISES, INC | BIN | C | 11/25/2019 | 3rd Party Insulation Certificate on file / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | NICK | NICK | | BIN | C | 6409276 |
DOUBLE DIAMOND ENTERPRISES, INC | B= | P | 11/20/2019 | Need to install address numbers for both units / Need insulation certificate and 3rd party inspection documentation / No insulation inspection done by RBD / All other elements of final OK -- Schedule a new Building Final when above items are complete. | NICK | NICK | | B= | P | 6405586 |
SNIDER CUSTOM HOMES | BFD | C | 11/20/2019 | | NICK | NICK | | BFD | C | 6405551 |
SNIDER CUSTOM HOMES | BFT | C | 11/20/2019 | | NICK | NICK | | BFT | C | 6405544 |
SNIDER CUSTOM HOMES | BLA | C | 01/30/2019 | | NICK | NICK | | BLA | C | 6092536 |
SNIDER CUSTOM HOMES | BFR | C | 01/16/2019 | Frame items completed | NICK | NICK | | BFR | C | 6079898 |
SNIDER CUSTOM HOMES | BFR | P | 01/11/2019 | 101- Missing clips in areas / Missing LSL at common wall next to stairs main level / Missing double 2"x4" under ends of same LSL // 102- Missing clips in areas / Top north east corner of main level missing section of shaftliner and top plate | SHAUN | SHAUN | | BFR | P | 6076430 |
SNIDER CUSTOM HOMES | BFR | R | 01/10/2019 | 101- Improper screws in clips and missing clips from separation wall / Damage to separation wall in areas / Tie corners of vaulted top plate / missing double 2x4 studs under LVL at stairs / Missing LSTI49 strap east wall main level / Load bearing studs in kitchen over notched / Roll blocks too small between joist at load bearing / Missing anchor bolt within 12" of break north side // 102- Missing clips and wrong screws used in clips at separation wall / Damaged areas in separation wall / Missing roof jacks / Missing ST22 straps from note A / Tie together top plate at vaulted / Stud space exceeds 24" at upstairs return / Missing double 2x4 studs under LVL at stairs / SStrap top plate continuous at fire place / Add corner hardware at stair landing / Roll blocks too small between joist in basement / Add anchor bolts within 12" of plate breaks in basement | SHAUN | SHAUN | | BFR | R | 6075307 |
SNIDER CUSTOM HOMES | BFN | C | 01/10/2019 | Foundation design on file 2,000 psf / Observations prior to permit fees paid | SHAUN | SHAUN | | BFN | C | 6074222 |
SNIDER CUSTOM HOMES | BFR | T | 01/09/2019 | PAID (REC#1568524) Inspection stopped on both units - Too many items - will need full frame re-inspect of both units - Verify installation of hardware called out on plans - expose rafter framing at fireplace in unit 102 so framing can be inspected - Address compromised studs for plumbing - tie walls together where top plates do not overlap / Request foundation design prior to any further field inspections | JUSTINL | JUSTINL | | BFR | T | 6073931 |
SNIDER CUSTOM HOMES | BFD | R | 12/28/2018 | Foundation drain observation done on June 18th 2018, permit not pulled until July 16th 2018 / Eng observation for foundation drain on file | NICK | NICK | | BFD | R | 6064403 |
SNIDER CUSTOM HOMES | BFN | R | 12/28/2018 | Still need foundation design / Eng observation of foundation reinforcement done on June 8th 2018, permit not pulled until July 16th 2018 | NICK | NICK | | BFN | R | 6064397 |
SNIDER CUSTOM HOMES | BFT | R | 12/28/2018 | Date of observation for footing per Eng observation is May 14th 2018, permit not pulled until July 16th 2018 / Eng observation for footing/foundation on file / Observation for foundation reinforcement done on June 8th 2018 / Grounding rod observed by Eng / Open hole on file / #2000psf / Drain usable / Still need foundation design | NICK | NICK | | BFT | R | 6064387 |
SNIDER CUSTOM HOMES | BIN | P | 12/10/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | TERRI | TERRI | | BIN | P | 6047195 |
SNIDER CUSTOM HOMES | BSP | P | 12/06/2018 | Porch frame and deck frame OK for both units / Still need all 3rd party observation for footing/foundation/drain / Still need open hole, soils and foundation design | NICK | NICK | | BSP | P | 6044739 |
SNIDER CUSTOM HOMES | BSP | R | 11/28/2018 | Need access to upper levels for inspection of porches / At time of inspection posts covered for post connection inspection at porches and decks / Please recall inspection | NICK | NICK | | BSP | R | 6036637 |
SNIDER CUSTOM HOMES | BLA | P | 11/28/2018 | Need all 3rd party observations for footing/foundation/drian / Need open hole report, foundation design and soils report / All lath OK | NICK | NICK | | BLA | P | 6036628 |
SNIDER CUSTOM HOMES | BSP | R | 10/24/2018 | Inspection for common wall per GA file NO. ASW 0810 / Need to install burn clips throughout with magnesium screws / All other aspect of wall OK per listing / Need all 3rd party observations for footing/foundation/drain, need open hole and soils report before next inspection | NICK | NICK | | BSP | R | 6004405 |
ROWAN ELECTRIC LLC | E= | C | 11/19/2019 | | JOHNN | JOHNN | | E= | C | 6403687 |
ROWAN ELECTRIC LLC | E= | T | 11/15/2019 | PAID (REC#1645184) correction not made: unit 1321: LV panel upstairs, outlet box needs to be screwed down, new correction, both cook tops have loose mc connectors, ---------------------------note: -240 volt cook tops have been removed from both basements, | JOHNN | JOHNN | | E= | T | 6400459 |
ROWAN ELECTRIC LLC | E= | R | 11/08/2019 | need correct address on meter brass tags, house # only,1321 or 1323 for appropriate unit, 120v cooktops in both units can not have cord cap on mc cable, needs hard wire and cb lockout, 1323: label circuit #2 in basement panel, 1321: LV panel outlet box is not securely fastened, | JOHNN | JOHNN | | E= | R | 6393083 |
ROWAN ELECTRIC LLC | E= | R | 10/24/2019 | Both units can not have a kitchen in basement, need to remove 240v cooktop circuits, unit 102: basement, blocking in mech rm, furnace disco: outer sheath not in box, add counter outlet in kitchen, upstairs: LV panel in closet is missing outlet, cb won't reset, unit 101: basement, can not get tester in outlet for dishwasher, to close to drain pipe, label cb #2, upstairs panel is missing panel cover screw, | JOHNN | JOHNN | | E= | R | 6379408 |
ROWAN ELECTRIC LLC | ER | C | 11/30/2018 | | JOHNN | JOHNN | | ER | C | 6039125 |
ROWAN ELECTRIC LLC | ES | C | 11/29/2018 | Residential Overhead: unit 101:200 amp,3w,ok to set meter--------unit 201:200 amp,3w,ok to set meter,---new duplex,---------------ir ufer, | JOHNN | JOHNN | | ES | C | 6038016 |
ROWAN ELECTRIC LLC | ER | R | 11/29/2018 | remove flex to oven on both basement units, PLANS SPECIFY NO COOKING APPLIANCE IN BASEMENT, 101:2nd floor bath fan connector falling out,----125 amp sub panel up stairs,ok,#6al,no mcc,------125 amp basement sub panel ok,no mcc,--------------201: 125amp upstairs panel,ok,#6al,no mcc,---------125 amp basement sub panel,ok,no mcc,------- | JOHNN | JOHNN | | ER | R | 6038012 |
ROWAN ELECTRIC LLC | ES | R | 11/13/2018 | | GARYL | GARYL | | ES | R | 6024463 |
ROWAN ELECTRIC LLC | ER | R | 11/13/2018 | Not Ready, Carpenters had to take some wiring loose, both units, unsafe access to both units | GARYL | GARYL | | ER | R | 6024450 |
ROWAN ELECTRIC LLC | ES | L | 11/12/2018 | Residential Overhead: 200 amp,3w,building locked, need to see ufer, outside ok for 101,102 just main panel, did not look at sub panels, | JOHNN | JOHNN | | ES | L | 6023177 |
ROWAN ELECTRIC LLC | ER | L | 11/12/2018 | no lock box code, | JOHNN | JOHNN | | ER | L | 6023174 |
GOSSAGE CONSTRUCTION | H= | C | 10/31/2019 | dryer vent connected see images | DAVIDH | DAVIDH | | H= | C | 6384191 |
GOSSAGE CONSTRUCTION | HSP | P | 10/24/2019 | NEED TO REVIEW THIS PROJECT WITH INSPECTORS BEFORE ANYMORE INSPECTIONS... APPEARS BUILDING MAY BE CHANGING TO A 4 UNIT BUILDING INSTEAD OF A DUPLEX... INFORMATION PROVIDED FROM ELECTRICAL SENIOR | JON | JON | | HSP | P | 6379564 |
GOSSAGE CONSTRUCTION | H= | P | 10/24/2019 | 3121 downstairs dryer vent disconnected note electric heat downstairs both units direct vent furnaces both units no alc both units , HI/LO transfer air for water heaters will accept pictures of dry vent repair | DAVIDH | DAVIDH | | H= | P | 6379271 |
BENNETT'S TOTAL HOME COMFORT | HI+ | C | 09/11/2019 | EACH GAS SYSTEM HAS BEEN RELOCATED FOR EACH C.S.U. METER. CONTRACTOR HAS INSTALLED 1 1/4" BLACK GAS MAIN TO WITHIN 3 FT OF METER LOCATION THEN TRANSITIONED TO 1" BLACK FOR THE LAST 3FT TO TIE INTO POINT OF DELIVERY. BOTH GAS SYSTEMS HAVE BEEN SIZED AT 1" PER THE 2015 IRC SECTION G2401.1. 10LB TEST FOR 1321 AND 1323 1" MAIN 1 FURNACE 1 WATER HEATER 1 COOKTOP 1 FIREPLACE | MATTM | MATTM | | HI+ | C | 6332126 |
GOSSAGE CONSTRUCTION | HC | C | 01/08/2019 | RELEASE METER | PAULO | PAULO | | HC | C | 6072194 |
GOSSAGE CONSTRUCTION | HRR | C | 01/08/2019 | INSPECTION NOTES ARE FOR BOTH A AND B UNITS. note: (A) finished basement, electric baseboard heat for basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c, received performance test. note: (B) finished basement, electric baseboard heat for basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c, received performance test. | PAULO | PAULO | | HRR | C | 6072187 |
GOSSAGE CONSTRUCTION | HRR | T | 12/12/2018 | PAID (REC#1566912): not ready. still need to address the following-- correct water heater vent termination clearances per manufacture installations, missing S.A. and R.A. in basement per plans (spliced plans for electric heat in basement was not approved). INSPECTION NOTES ARE FOR BOTH A AND B UNITS. note: (A) finished basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c, received performance test. note: (B) finished basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c, received performance test. | PAULO | PAULO | | HRR | T | 6051034 |
GOSSAGE CONSTRUCTION | HRR | P | 12/12/2018 | need to address the following-- correct water heater vent termination clearances per manufacture installations, missing S.A. and R.A. in basement per plans, install and complete all bath fan exhaust ducts to fans. INSPECTION NOTES ARE FOR BOTH A AND B UNITS. note: (A) finished basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c, received performance test. note: (B) finished basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c, received performance test. | PAULO | PAULO | | HRR | P | 6050034 |
GOSSAGE CONSTRUCTION | HRR | P | 12/06/2018 | need to address the following-- correct water heater vent termination clearances per manufacture installations, missing S.A. and R.A. in basement per plans, install and complete all bath fan exhaust ducts to fans. (IS THIS A PERFORMANCE TEST?). INSPECTION NOTES ARE FOR BOTH A AND B UNITS. note: (A) finished basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c. note: (B) finished basement, outside air to return, direct vent furnace, indirect vent water heater, no a/c. | PAULO | PAULO | | HRR | P | 6045397 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 12/03/2018 | 10# test ok to 1323 (A) note: 1" main at 30' to 1- furnace, 1- water heater, 1- range and 1- fire place. 10# test ok to 1323 (B) note: 1" main at 30' to 1- furnace, 1- water heater, 1- range and 1- fire place. | PAULO | PAULO | | HI | C | 6041428 |
BLUE FLAME GAS COMPANY, INC. | HI | R | 11/28/2018 | not ready. waived trip fee. all points of access to 1323 (A) are locked, no lock box code. | PAULO | PAULO | | HI | R | 6036934 |
BLUE FLAME GAS COMPANY, INC. | HI | P | 11/07/2018 | no access to 1323 (A) for sizing and support inspection. 10# test ok to 1323 (A). 10# test ok to 1323 (B) note: 1" main at 30' to 1- furnace, 1- water heater, 1- range and 1- fire place. | PAULO | PAULO | | HI | P | 6019168 |
B & L PLUMBING, INC. | P= | C | 11/01/2019 | | JOHNS | JOHNS | | P= | C | 6385726 |
B & L PLUMBING, INC. | P= | P | 10/09/2019 | @ 1321 need drain down @ irrigation @ outside and inside, can not locate tempeirng valve for mstr tub, upr hall water closet 13" off cab, rest ok. NOTE: finished bsmnt, pvb ok
@ 1323 can not locate tempering valve for mstr tub, rest ok. NOTE: finished bsmnt, no irrigation stub | JOHNS | JOHNS | | P= | P | 6363493 |
B & L PLUMBING, INC. | PTO | C | 10/29/2018 | Finished basements, no irrigation | SHANEN | SHANEN | | PTO | C | 6008788 |
B & L PLUMBING, INC. | PTO | P | 10/26/2018 | 102 not ready, 101 OK - finished basement | SHANEN | SHANEN | | PTO | P | 6007462 |
B & L PLUMBING, INC. | PTO | P | 10/26/2018 | 102 no test, | SHANEN | SHANEN | | PTO | P | 6007454 |
B & L PLUMBING, INC. | PB | C | 07/19/2018 | | SHANEN | SHANEN | | PB | C | 5907845 |
SNIDER CUSTOM HOMES | XMS | T | 12/28/2018 | PAID (REC#1567471) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: revised lower level from forced air to electric heat | DALEH | DALEH | | XMS | T | 6064791 |
SNIDER CUSTOM HOMES | XBS | P | 12/12/2018 | PLAN SPLICE: (No Fee) by: DANM for Construction: New IECC Certificates for each unit - no change from approved | DANM | DANM | | XBS | P | 6050036 |