MANS HOMES, LLC | B= | C | 09/22/2020 | | BERTW | BERTW | | B= | C | 6713901 |
MANS HOMES, LLC | BE | T | 08/26/2020 | PAID (REC#1707996): For TCO | JANE | JANE | | BE | T | 6686680 |
MANS HOMES, LLC | B= | P | 08/26/2020 | Temp CO: Per Bert ( Expires: 9/25/2020 12:00:00 AM) | JANE | JANE | | B= | P | 6686676 |
MANS HOMES, LLC | B= | P | 08/25/2020 | Changed to a partial by Bert after consult with Chip Taylor, need splice to remove fire barrier with the installation of the manual fire alarm system on a separate permit. -- Schedule a new Building Final when above items are complete. | BERTW | BERTW | | B= | P | 6684965 |
MANS HOMES, LLC | B= | R | 08/24/2020 | after further review still need to complete inspections for 2 HR fire barrier per previous comments / Fire barrier is life safety item | DANE | DANE | | B= | R | 6683739 |
MANS HOMES, LLC | B= | P | 08/20/2020 | still need to complete inspections for 2hr fire barrier - see comments from BSP inspection dated 26FEB20 / other corrections okay -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 6680553 |
MANS HOMES, LLC | B= | P | 08/19/2020 | still need to complete inspections for 2hr fire barrier - see comments from BSP inspection dated 26FEB20 / still missing protection for water supply lines under sink in women's restroom / other corrections okay -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 6678919 |
MANS HOMES, LLC | B= | P | 08/18/2020 | need to complete inspections for 2hr fire barrier - see comments from BSP inspection dated 26FEB20 / missing protection for exposed pipes under sink in restrooms / reflective surface of mirror in restrooms is over 40" off of finished floor | BRIANB | BRIANB | | B= | P | 6677267 |
MANS HOMES, LLC | BSP | P | 02/26/2020 | 2hr Fire barrier inspection - see approved plan splice dated 11FEB20 / observed 1" American AG-S gyp panels and steel framing members - UL V455 / discussed with site rep needing fire stop details for all through penetrations and head of wall and inspected / also reviewed details for 2hr fire barrier UL V455 and required inspections for assembly - (2) layers of gyp / pending other inspections | BRIANB | BRIANB | | BSP | P | 6492909 |
MANS HOMES, LLC | BFR | P | 09/03/2019 | no inspection performed / met with site rep Dan and reviewed accessible elements | BRIANB | BRIANB | | BFR | P | 6322366 |
MANS HOMES, LLC | BFR | P | 08/28/2019 | observed interior light gauge mtl wall framing and hard lid framing over restrooms / pending other rough inspections including mechanical inspection for hood wall / site rep unavailable at time of inspection to review accessible elements | BRIANB | BRIANB | | BFR | P | 6317821 |
SPECIAL SYSTEMS DESIGN,LLC | E= | C | 09/18/2020 | FIRE ALARM INSPECTION: | ROB | ROB | | E= | C | 6711509 |
SPECIAL SYSTEMS DESIGN,LLC | ER | C | 09/18/2020 | FIRE ALARM INSPECTION: Rough complete / | ROB | ROB | | ER | C | 6711493 |
SPECIAL SYSTEMS DESIGN,LLC | E= | C | 09/18/2020 | FIRE ALARM INSPECTION: Rough complete / | ROB | ROB | | E= | C | 6711494 |
RICHIE-RICH ELECTRIC | E= | C | 12/20/2019 | Still need to address one line for OCPD and Feeders to Panel K 1, not installed per print /------------------Partial changed to complete by Dean. Splice has been submitted and approved, feeder to panel K1 verified by inspector CS, and pics of breaker rating for panels accepted-------------------------- | ROB | ROB | | E= | C | 6433883 |
RICHIE-RICH ELECTRIC | E= | P | 12/19/2019 | Need to label disconnects on 2- exhaust fan with panel and ckt. numbers / MOP is 15 amp for 2 exhuast fans / Need GFCI recpt near sink in back kitchen area / Still need to address one line for Panel K 1 / | ROB | ROB | | E= | P | 6432355 |
RICHIE-RICH ELECTRIC | E= | R | 12/18/2019 | Need to check exhaust on roof / Feeder for panel K 1 doesn't match one line / All kitchen recpts and recpts. within 6' of sinks need to be GFCI protected / All brekers in T 3 and K 1 need to be 22k / | ROB | ROB | | E= | R | 6430743 |
RICHIE-RICH ELECTRIC | ER | P | 11/21/2019 | Rough ok for rest of grid ceiling ok / | ROB | ROB | | ER | P | 6406741 |
RICHIE-RICH ELECTRIC | ER | P | 11/20/2019 | Need support wire for all recess cans in grid ceiling--recall when ready / Grid ceiling in kitchen and serving areas ok / | ROB | ROB | | ER | P | 6405231 |
RICHIE-RICH ELECTRIC | ER | P | 08/28/2019 | Rest of walls ok / | ROB | ROB | | ER | P | 6316941 |
RICHIE-RICH ELECTRIC | ER | P | 08/27/2019 | Rough ok for kitchen area walls only / Need to lower rest to ansi 117 requirements / Panel height ok if it has lockable cover, otherwise max breaker height is 48"/ | ROB | ROB | | ER | P | 6315239 |
DRUMMOND PLUMBING LLC | H= | C | 05/29/2020 | | MARKB | MARKB | | H= | C | 6586779 |
AIRTECH MECHANICAL, INC. | H= | C | 03/09/2020 | TEST AND BALANCE REPORT RECEIVED, SEE IMAGES / | MARKB | MARKB | | H= | C | 6503728 |
AIRTECH MECHANICAL, INC. | H= | P | 03/04/2020 | WRONG JOB CALLED IN. NO INSPECTION THIS SITE. | MARKB | MARKB | | H= | P | 6500476 |
AIRTECH MECHANICAL, INC. | H= | P | 02/27/2020 | Mechanical final ok pending receipt of test and balance report / INTERLOCKS CONFIRMED, THERMOSTAT AND REMOTE INDICATOR COMPLETE. | MARKB | MARKB | | H= | P | 6494977 |
AIRTECH MECHANICAL, INC. | HD | C | 02/27/2020 | SPLICE ON FILE FOR GREASE DUCT. EXHAUST FANS ON ROOF AND WRAP COMPLETE. | MARKB | MARKB | | HD | C | 6494975 |
DRUMMOND PLUMBING LLC | H= | P | 02/27/2020 | CAN FINAL CONTRACTOR ONCE REQUESTED. | MARKB | MARKB | | H= | P | 6494970 |
AIRTECH MECHANICAL, INC. | HV | C | 02/27/2020 | WATER HEATER VENT COMPLETE | MARKB | MARKB | | HV | C | 6494968 |
AIRTECH MECHANICAL, INC. | H= | L | 01/21/2020 | SITE CANCELLED BY CONTRACTOR | MARKB | MARKB | | H= | L | 6458983 |
AIRTECH MECHANICAL, INC. | HD | P | 12/31/2019 | Need mechanical contractor attached to permit for water heater vent and inspection. South grease fan flange at curb needs to be ground smooth and light tested. Both grease fans lack a high temperature gasket. Grease fans need to be extended level with building components within 10'. Water heater vent is within 10' makeup air intake. Need approved plan splice on file for changed grease duct. Second layer of grease duct insulation needs to extend to bottom of curb flange and all the way down to hood and installed per manufacturer instructions. Grease cups need to be installed under hood. Need to confirm hood interlocks. Stock pot range needs proper 6" hood overhang. ABOVE CEILING DUCT - FLEX/DIFFUSERS/THERMOSTAT/ DUCT SMOKE REMOTE INDICATOR COMPLETE. PVC PIPE IN HOOD WALL HAS BEEN CHANGED TO CAST IRON. | MARKB | MARKB | | HD | P | 6440078 |
DRUMMOND PLUMBING LLC | H= | P | 12/11/2019 | FINAL PENDING - Need a mechanical contractor attached to permit for water heater vent. | MARKB | MARKB | | H= | P | 6424462 |
DRUMMOND PLUMBING LLC | HC | C | 12/11/2019 | ADDING LOAD PER PLAN FOR NEW RESTAURANT | MARKB | MARKB | | HC | C | 6424461 |
DRUMMOND PLUMBING LLC | HI | C | 12/11/2019 | PIPING PER PLAN SPLICE. | MARKB | MARKB | | HI | C | 6424458 |
DRUMMOND PLUMBING LLC | HI | P | 11/14/2019 | 10 PSI PRESSURE TEST OK BUT piping does not match plan. | MARKB | MARKB | | HI | P | 6400065 |
AIRTECH MECHANICAL, INC. | HD | P | 10/29/2019 | GREASE DUCT - FIRST LAYER OF WRAP COMPLETE FOR BOTH GREASE DUCTS FROM CURBS TO HOOD. | MARKB | MARKB | | HD | P | 6383223 |
AIRTECH MECHANICAL, INC. | HD | P | 10/22/2019 | NEED REVISED / APPROVED PLANS FOR TWO 14" CAPTIVE AIR PRE MANUFACTURED GREASE DUCTS INSTALLED INSTEAD OF 15 X 14 WELDED - TWO SINGLE WALL CAPTIVE AIR GREASE DUCTS OK / OK TO WRAP. EXISTING RTU SUPPLY MAIN TRUNK AND BRANCH LINE DUCT ROUGH OK / OK TO WRAP . 1- 8" SUPPLY IN KITCHEN IS NOT COMPLETE. | LIDO | LIDO | | HD | P | 6376875 |
AIRTECH MECHANICAL, INC. | HSP | P | 09/03/2019 | HOOD WALL INSPECTION - Hood wall has a 2" PVC plumbing vent in it. HOOD IS A ZERO CLEARANCE FOR BACK AND LEFT SIDE BUT EQUIPMENT MAY REQUIRE CLEARANCE TO COMBUSTIBLES. | MARKB | MARKB | | HSP | P | 6322645 |
AIRTECH MECHANICAL, INC. | HSP | L | 08/30/2019 | No call ahead or lock box number provided - site locked | MARKB | MARKB | | HSP | L | 6320899 |
AIRTECH MECHANICAL, INC. | HSP | L | 08/29/2019 | No call ahead or lock box number provided. Site locked. | MARKB | MARKB | | HSP | L | 6319383 |
FLACO'S PLUMBING, LLC | P= | C | 12/27/2019 | correction made, changed aav to vtr | TED | TED | | P= | C | 6437951 |
FLACO'S PLUMBING, LLC | P= | P | 12/23/2019 | bathroom on the left, toilet trip lever on wrong side, support backflow device, install tempering valves on hand sinks, still need letter for aav in bathroom wall | TED | TED | | P= | P | 6435252 |
FLACO'S PLUMBING, LLC | P= | L | 12/18/2019 | Field cancel. | DANR | DANR | | P= | L | 6430879 |
FLACO'S PLUMBING, LLC | PTO | P | 11/25/2019 | Domestic water inspection: Need overhead pipe support, missing balance valves on recir, make up water and drain to MAU, drawings show existing 1-1/2" backflow which is not there, need domestic water insulation, rest ok for domestic water. Note: at final check MAU make up water backflow - water heater, need engineer approval for AAV rest room in wall men's side. | DANR | DANR | | PTO | P | 6410419 |
FLACO'S PLUMBING, LLC | PTO | P | 11/19/2019 | dwv above walls in ceiling through roof ok | TED | TED | | PTO | P | 6404263 |
T'S PLUMBING AND HEATING, INC. | PTO | R | 09/20/2019 | Need licensed gas contractor to attached to permit, Mechanical inspects gas lines. | DANR | DANR | | PTO | R | 6342008 |
T'S PLUMBING AND HEATING, INC. | PTO | T | 09/18/2019 | PAID (REC#1631458): No Piping overhead complete. | DANR | DANR | | PTO | T | 6339794 |
T'S PLUMBING AND HEATING, INC. | PTO | P | 08/27/2019 | In wall DWV and domestic water inspection: Need mechanical inspection hood wall to check clearances on plumbing pipe, ok to insulate in wall domestic water pipe, rest of in wall DWV and domestic water ok. Note: check backflow MAU on overhead piping, by final need engineer approval AAV at rest rooms in wall mens side. | DANR | DANR | | PTO | P | 6315793 |
T'S PLUMBING AND HEATING, INC. | PTO | P | 08/23/2019 | In wall DWV and domestic water inspection: **Need mechanical inspection on hood wall** Low test domestic water, need mechanical inspection hood wall to check clearances on plumbing pipe, need baseplate nail protection, missing dump sink DWV piping, need engineer approval AAV at rest rooms in wall mens side. Note: check backflow MAU on overhead piping, received engineer letter for pex. | DANR | DANR | | PTO | P | 6312179 |
T'S PLUMBING AND HEATING, INC. | PTO | P | 08/19/2019 | In wall DWV and domestic water inspection: Need test all DWV and domestic water piping, need engineer approval for pex piping ( drawings show L copper), missing nail protection through out, need to pipe dump sink DWV per drawing and to code, anchor toilet flanges ( need side clearance 16"-18" off finish wall at final), need insulation domestic water piping, re-inspect all. | DANR | DANR | | PTO | P | 6305459 |
T'S PLUMBING AND HEATING, INC. | PB | C | 07/22/2019 | sanitary and grease drains | TED | TED | | PB | C | 6271593 |
T'S PLUMBING AND HEATING, INC. | PB | R | 07/19/2019 | no call ahead, no one on site, doors locked | TED | TED | | PB | R | 6270062 |
MANS HOMES, LLC | XBS | T | 08/27/2020 | PAID (REC#1714937): PLAN SPLICE FEE: $50 by: LBENNETT for Construction: Removed 2-hour fire barrier (not required) | LBENNETT | LBENNETT | | XBS | T | 6687433 |
DRUMMOND PLUMBING LLC | XMS | T | 03/05/2020 | PAID (REC#1683883): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: new splice revised gas piping | TCRIPPEN | TCRIPPEN | | XMS | T | 6501678 |
MANS HOMES, LLC | XBS | T | 02/11/2020 | PAID (REC#1661528) PLAN SPLICE FEE: $50 by: LBENNETT for Construction: New 2-hr fire barrier between utility room and Pho restaurant | LBENNETT | LBENNETT | | XBS | T | 6478809 |
DRUMMOND PLUMBING LLC | XMS | T | 01/22/2020 | PAID (REC#1657498) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: Revised grease duct sizes and changed from square to round. Adjusted velocity | TCRIPPEN | TCRIPPEN | | XMS | T | 6460697 |
RICHIE-RICH ELECTRIC | XES | P | 01/06/2020 | PLAN SPLICE: (No Fee) by: SHELBY for Electrical: To address inspector comments | SHELBY | SHELBY | | XES | P | 6444366 |
DRUMMOND PLUMBING LLC | XMS | T | 12/09/2019 | PAID (REC#1649638): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: new splice revised gas piping | TCRIPPEN | TCRIPPEN | | XMS | T | 6420962 |