HOMEOWNER | B= | P | 10/13/2023 | Insulation ER on file. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | P | 7886909 |
HOMEOWNER | B= | R | 10/13/2023 | Inspection request states image upload, no images attached. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | R | 7886863 |
HOMEOWNER | B= | P | 10/05/2023 | Provide ES Report for spray foam insulation / Installation certificate received on site / Rest of building final OK Note: A/C complete x 2 / Crawl Space / Front and back decks -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | ANGELW | ANGELW | | B= | P | 7879133 |
HOMEOWNER | BSP | R | 07/13/2023 | Water test paper work to be submitted to plumbing inspector on a plumbing inspection request | TRENTP | TRENTP | | BSP | R | 7796505 |
HOMEOWNER | BSP | R | 06/08/2023 | No images or inspection description provided | TRENTP | TRENTP | | BSP | R | 7766023 |
HOMEOWNER | BSP | P | 06/08/2023 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TRENTP | TRENTP | | BSP | P | 7766016 |
HOMEOWNER | BIN | P | 04/06/2022 | Need to provide final insulation certificate and air leakage test by 3rd party / Rough insulation observation on file | TRENTP | TRENTP | | BIN | P | 7327499 |
HOMEOWNER | BIN | R | 04/05/2022 | Homeowner states 3rd party observed insulation, need to provide 3rd party insulation observation certificate / Image upload requested. If unfamiliar with uploading images for an inspection, please use the following link: https://youtu.be/QS0hdGSBA6o / | TRENTP | TRENTP | | BIN | R | 7326007 |
HOMEOWNER | BIN | L | 04/04/2022 | Cancelled by homeowner | TRENTP | TRENTP | | BIN | L | 7324348 |
HOMEOWNER | BFR | C | 03/10/2022 | Items corrected | TRENTP | TRENTP | | BFR | C | 7297003 |
HOMEOWNER | BFR | P | 03/09/2022 | Incomplete fireblocking at following locations: Top plate throughout garage, top plate at each side of front door, and top and bottom plates at interior walls throughout kitchen / Need to tie top plates together where interrupted by front porch beam at southeast laundry room exterior wall / Rest okay / Crawlspace, front and rear decks | TRENTP | TRENTP | | BFR | P | 7295917 |
HOMEOWNER | BIN | P | 03/08/2022 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 7294083 |
HOMEOWNER | BSP | P | 12/23/2021 | Changed to BSP / Engineer letter for trusses on file / | ERIKK | ERIKK | | BSP | P | 7219544 |
HOMEOWNER | BFD | C | 12/15/2021 | Drain not required per soils report, crawlspace not habitable space | TRENTP | TRENTP | | BFD | C | 7210386 |
HOMEOWNER | BSP | R | 12/14/2021 | Inspection changed to BSP after too many incorrect frame items found / Used inspection as a consultation to discuss requirements on engineer stamped plans, hardware callouts and requirements, and requirements for code during frame inspection / Need to complete BFD prior to further inspection / Need to upload truss repair details / Need to complete fireblocking/draftstopping throughout | TRENTP | TRENTP | | BSP | R | 7208603 |
HOMEOWNER | BSP | P | 12/14/2021 | Decks okay per engineer observation/clarification on file and previous inspection | TRENTP | TRENTP | | BSP | P | 7207673 |
HOMEOWNER | BSP | R | 12/10/2021 | Inspection for front and rear decks / Middle beam piers for both decks poured at time of inspection, need to provide 3rd party observation or expose to confirm depth / Outside flush beams on both decks do not bear on posts, beams are fastened to outside of 8x8 posts with (2) 16D nails and squash blocks underneath / Ledgers to be attached with 2 SDS screws at 16 inches O.C., observed 1 SDS screw at 16in O.C. staggered | TRENTP | TRENTP | | BSP | R | 7205522 |
HOMEOWNER | BSP | R | 11/23/2021 | Need to submit new deck frames as splice to plans, decks not on original plans / Splice required, please submit splice for changes in scope. If unfamiliar in submitting electronic splice, please click the following link: https://youtu.be/dG3kHpgDP0w / | TRENTP | TRENTP | | BSP | R | 7186395 |
HOMEOWNER | BSP | P | 10/12/2020 | Rear porch okay | TRENTP | TRENTP | | BSP | P | 6738144 |
HOMEOWNER | BSP | P | 10/12/2020 | Updated engineer detail for porch holddown hard ware on file / Pending field inspection | TRENTP | TRENTP | | BSP | P | 6737255 |
HOMEOWNER | BSP | P | 09/23/2020 | Will need to re inspect hold down hardware for rear porch lid / Front porch posts and lid, hold downs and side popout lids okay / | TRENTP | TRENTP | | BSP | P | 6716957 |
HOMEOWNER | BSP | P | 09/22/2020 | Engineer letter for frame changes on file | TRENTP | TRENTP | | BSP | P | 6713717 |
HOMEOWNER | BSP | P | 07/13/2020 | Exterior piers corrected | TRENTP | TRENTP | | BSP | P | 6634791 |
HOMEOWNER | BSP | R | 07/10/2020 | Pier depth for exterior piers is only 3 ft with 2 ft of sonotube above grade / Plans call for 60 inch piers / Sonotubes do not equate to total depth of piers | TRENTP | TRENTP | | BSP | R | 6633580 |
HOMEOWNER | BFN | C | 07/08/2020 | Foundation re enforcement okay / Observed ICF panels throughout / Eufer noted / NOTE: Will need to inspect exterior piers once they are dug as a BSP | TRENTP | TRENTP | | BFN | C | 6630704 |
HOMEOWNER | BFT | C | 06/30/2020 | Soils report, open hole, and foundation design on file / 2000 psf bearing capacity / Footing re enforcement okay / ICF splice on file | TRENTP | TRENTP | | BFT | C | 6622149 |
HOMEOWNER | BFT | R | 06/25/2020 | No inspection performed / Discussed with homeowner requirements for inspection / Will need copy of soils report, open hole observation, and foundation design prior to inspection / Change to ICF foundation will need to be submitted as a splice | TRENTP | TRENTP | | BFT | R | 6617245 |
HOMEOWNER | E= | C | 08/19/2022 | Corrections made. | AARONR | AARONR | | E= | C | 7489258 |
HOMEOWNER | E= | R | 08/18/2022 | 2 smokes no power -------------- label a/c disconnects ----------------- re ID wire whites at a/c disconnect and inside panel -------------- bedroom closet light needs to be enclosed | CRAIG | CRAIG | | E= | R | 7488251 |
HOMEOWNER | ER | C | 12/10/2021 | Crawler / Two furnaces in crawler & no sump pumps / No jet tub installed / No Cent Vac / non -Irreversible UFER connection / Discussed AFCI/GFCI/TR requirements with owner. / | JOSEPH | JOSEPH | | ER | C | 7204788 |
HOMEOWNER | ES | C | 04/28/2021 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 6951116 |
HOMEOWNER | H= | C | 12/27/2022 | Whole house ventilation being achieved through exhaust fan located in bathroom / Whole house ventilation switch located in bathroom / Whole house ventilation switch located on wall outside of master bedroom / NOTE / Conditioned crawl space / Direct vent furnace x 2 / Direct vent water heater / A/C complete / Outside air with damper to furnace return x 2 via ERVs in crawlspace / Gas regulators set at all appliances, 2 in garage and all others in crawlspace for each appliance / | CASEYM | CASEYM | | H= | C | 7620318 |
HOMEOWNER | HC | C | 11/23/2021 | RELEASE 2 LB METER | JHORSMAN | JHORSMAN | | HC | C | 7187429 |
HOMEOWNER | HI | C | 11/23/2021 | 10 LB TEST OK ON NEW HOUSE GAS PIPE AND EXISTING UNDERGROUND GAS PIPE / 3/4 INCH MAIN / 2 FURNACES / 1 WATER HEATER / 1 RANGE / 2 FIREPLACES / 1 GARAGE HEATER / 1 DRYER / AT FINAL WILL NEED TO SEE REGULATORS IN PLACE AT EACH APPLIANCE/ MEDIUM PRESSURE STENCILING/ AND 2 LB APPROVAL LETTER FROM GAS PROVIDER | JHORSMAN | JHORSMAN | | HI | C | 7187423 |
HOMEOWNER | HRR | C | 11/03/2021 | | JHORSMAN | JHORSMAN | | HRR | C | 7164574 |
HOMEOWNER | HRR | P | 11/02/2021 | INSTALL VENTING FOR GARAGE HEATER/ FURNACE 2 EXHAUST IS BACK GRADED AT FIRST 90 DEGREE ELBOW/ Whole house ventilation being achieved through exhaust fan located in bathroom. / Verify whole house ventilation switch location at final / NOTE / CONDITIONED CRAWL SPACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN X2 VIA ERV/ DIRECT VENT FURNACE X2/ DIRECT VENT WATER HEATER / A/C ROUGH, COIL AND LINESET X2/ | JHORSMAN | JHORSMAN | | HRR | P | 7162343 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 09/08/2021 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / | JHORSMAN | JHORSMAN | | HV | C | 7100575 |
HOMEOWNER | HO | C | 06/15/2021 | 10 LB TEST OK FOR 192' OF 3/4'' POLY WITH TRACER FROM METER LOCATION AT DETACHED GARAGE TO RISER AT HOME. BY FINAL WILL NEED TO SEE MEDIUM PRESSURE STENCILING AND LETTER FROM BLACK HILLS APPROVING THE 2 PSIG SYSTEM | TREVORH | TREVORH | | HO | C | 7001978 |
HOMEOWNER | HO | P | 06/14/2021 | AT NEXT INSPECTION WILL NEED TO SEE TRACER WIRE INSTALLED OK TO ATTACH PICTURE TO THE NEXT INSPECTION REQUEST, 10 LB TEST OK FOR 192' OF 3/4'' POLY FROM METER LOCATION AT DETACHED GARAGE TO RISER AT HOME. BY FINAL WILL NEED TO SEE MEDIUM PRESSURE STENCILING AND LETTER FROM BLACK HILLS APPROVING THE 2 PSIG SYSTEM | TREVORH | TREVORH | | HO | P | 7001457 |
J D PLUMBING AND HEATING LLC | P= | C | 10/04/2023 | | TAYLOR | TAYLOR | | P= | C | 7876271 |
HOMEOWNER | P= | P | 08/01/2023 | install condensate drain/ pan at water heater, need approved material at T&P drain, need proper air gap at master tub spout, install vacuum breakers at all hand held devices, missing aav at hub drain at crawl space, rest ok, pvb installed. | TAYLOR | TAYLOR | | P= | P | 7813725 |
HOMEOWNER | PWO | C | 08/01/2023 | | TAYLOR | TAYLOR | | PWO | C | 7813717 |
HOMEOWNER | P= | P | 08/01/2023 | certificate of potable water ok ( see images ). | TAYLOR | TAYLOR | | P= | P | 7813351 |
J D PLUMBING AND HEATING LLC | PTO | C | 12/14/2021 | need pwo by final | JOSEPHD | JOSEPHD | | PTO | C | 7207594 |
J D PLUMBING AND HEATING LLC | PTO | P | 12/31/2020 | need pwo inspection, need to conduct more research into yard hydrant backflow used in pit, note: per contractor garage is heated, aav @ both jack and jill sinks, both master lavs, at ceiling in laundry room, at hub drain in crawlspace, need back water at hub drain in crawlspace by final, irrigation stub, tempering under master tub in crawlspace | JOSEPHD | JOSEPHD | | PTO | P | 6823274 |
HOMEOWNER | XBS | T | 12/06/2021 | PAID (REC#1827759) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Added decks | SHELLEY | SHELLEY | | XBS | T | 7197877 |
HOMEOWNER | XBS | T | 06/26/2020 | PAID (REC#1692226) PLAN SPLICE FEE: $50 by: LBENNETT for Construction: Revised crawlspace foundation to ICF | LBENNETT | LBENNETT | | XBS | T | 6619076 |
HOMEOWNER | XBS | P | 06/22/2020 | PLAN SPLICE: (No Fee) by: LBENNETT for Construction: Added missing mono trusses | LBENNETT | LBENNETT | | XBS | P | 6612996 |