INNOVATIVE CONSTRUCTION, INC. | B= | C | 04/06/2022 | | ADAML | ADAML | | B= | C | 7329117 |
INNOVATIVE CONSTRUCTION, INC. | B= | P | 03/22/2022 | Temp CO: pending building final ( Expires: 4/21/2022 12:00:00 AM) | NELIDA | NELIDA | | B= | P | 7309877 |
INNOVATIVE CONSTRUCTION, INC. | B= | P | 03/14/2022 | Complete mechanical final / Missing door hardware on glass office doors / Will need to verify fire doors at entrance once installed ( Temp doors installed currently ) -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), PEAK HEATING & AIR CONDITIONING, INC. Mechanical Final Inspection is not Completed yet. | ADAML | ADAML | | B= | P | 7300725 |
INNOVATIVE CONSTRUCTION, INC. | BSP | P | 02/16/2022 | Ceiling grid wires OK | ADAML | ADAML | | BSP | P | 7273078 |
INNOVATIVE CONSTRUCTION, INC. | BFR | P | 02/10/2022 | 1st layer drywall installed at walls and ceiling 2nd layer at ceiling installed when inspector was still on site and okay. | NATHAN | NATHAN | | BFR | P | 7266526 |
INNOVATIVE CONSTRUCTION, INC. | BFR | P | 02/08/2022 | Framing corrected / Discussed rated assemblies U419 using USG and HM 7100 using American Gypsum screw inspection needed. | NATHAN | NATHAN | | BFR | P | 7263836 |
INNOVATIVE CONSTRUCTION, INC. | BFR | P | 01/21/2022 | Attach mechanical / All metal framing OK / Need to obtain splice with a detail showing how the rated wall at new entrance will tie in to the window mullion at the exterior wall ( Any added framing will need to be inspected ) / Reviewed accessible elements /
Note- Will need to see drywall screws at new rated entrance and grid wire inspection for new grid ceilings. | ADAML | ADAML | | BFR | P | 7246828 |
INTERMOUNTAIN POWER SERVICES INC | E= | C | 02/23/2022 | | BRETC | BRETC | | E= | C | 7279829 |
INTERMOUNTAIN POWER SERVICES INC | EP | C | 02/23/2022 | 50 amp R1F-1 - Ok | BRETC | BRETC | | EP | C | 7279822 |
STILSON ELECTRIC SYSTEMS, INC. | E= | C | 02/22/2022 | FIRE ALARM INSPECTION: | BRETC | BRETC | | E= | C | 7278442 |
STILSON ELECTRIC SYSTEMS, INC. | ER | C | 02/22/2022 | FIRE ALARM INSPECTION: Ceilings - Ok | BRETC | BRETC | | ER | C | 7278435 |
INTERMOUNTAIN POWER SERVICES INC | ER | C | 02/22/2022 | Ceilings - Ok | BRETC | BRETC | | ER | C | 7278386 |
INTERMOUNTAIN POWER SERVICES INC | ER | P | 02/07/2022 | Walls complete / Entry hard lid - Ok | BRETC | BRETC | | ER | P | 7261112 |
STILSON ELECTRIC SYSTEMS, INC. | ER | P | 01/14/2022 | FIRE ALARM INSPECTION: Walls ok except for front door area - FA will be in ceilings | BRETC | BRETC | | ER | P | 7240083 |
INTERMOUNTAIN POWER SERVICES INC | ER | P | 01/11/2022 | Need to attach Fire Alarm to permit / All walls except entrance door wall - Ok / Panel pipe and back box - Ok / Over floor raceway in wall, cut sheet - Ok | BRETC | BRETC | | ER | P | 7234987 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 03/21/2022 | RETURN GRILLS, TRANSFER AND CONTROLS COMPLETE | MARKB | MARKB | | H= | C | 7309196 |
PEAK HEATING & AIR CONDITIONING, INC. | HSP | P | 03/18/2022 | PICTURES RECEIVED OF THERMOSTATS. SEE IMAGE. | LIDO | LIDO | | HSP | P | 7307691 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 03/18/2022 | Suite 101 locked no access. Contractor to re schedule. | LIDO | LIDO | | H= | P | 7307686 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 03/10/2022 | TEST AND BALANCE REPORT RECEIVED | MARKB | MARKB | | H= | P | 7297135 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 02/23/2022 | FINAL PENDING - Complete thermostats, return grills, transfer, provide test and balance report. ABOVE CEILING DUCT - FLEX AND DIFFUSERS INSTALLED PER PLAN. | MARKB | MARKB | | H= | P | 7279995 |
CRONEN PLUMBING AND HEATING, INC. | P= | C | 03/01/2022 | | LEE | LEE | | P= | C | 7286192 |
CRONEN PLUMBING AND HEATING, INC. | PTO | C | 03/01/2022 | | LEE | LEE | | PTO | C | 7286191 |
CRONEN PLUMBING AND HEATING, INC. | PB | R | 03/01/2022 | SUITE # 105 REQUIRES A SEPARATE PERMIT | LEE | LEE | | PB | R | 7286187 |
CRONEN PLUMBING AND HEATING, INC. | PTO | P | 01/12/2022 | NEED PLANS REVISED TO SHOW FUTURE SINK ROUGH IN ADJACENT SUITE -- NEED PROPER MISSION BAND AT CAST TO PLASTIC TRANSITION -- NEED DOMESTIC WATER INSULATED -- NOTES FOR RBD - STILL NEED ALL WATER HEATER ASSOCIATED PIPING INSPECTED -- AAV AT SINK ON FINAL | LEE | LEE | | PTO | P | 7236408 |
PEAK HEATING & AIR CONDITIONING, INC. | XMS | T | 02/04/2022 | PAID (REC#1841290): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: cloud | DALEH | DALEH | | XMS | T | 7259899 |
INNOVATIVE CONSTRUCTION, INC. | XBS | P | 02/01/2022 | PLAN SPLICE: (No Fee) by: BPHILLIPS for Construction: Provided detail for rated wall @ mullion. | BPHILLIPS | BPHILLIPS | | XBS | P | 7256262 |
INTERMOUNTAIN POWER SERVICES INC | XES | T | 01/31/2022 | PAID (REC#1840104) PLAN SPLICE FEE: $50 by: DANIELG for Electrical: Revised panel schedule R1F and R1F-1. | DANIELG | DANIELG | | XES | T | 7254894 |
INNOVATIVE CONSTRUCTION, INC. | XBS | P | 01/21/2022 | PLAN SPLICE: (No Fee) by: BPHILLIPS for Construction: Revised wall assembly detail. | BPHILLIPS | BPHILLIPS | | XBS | P | 7246348 |
INNOVATIVE CONSTRUCTION, INC. | XMS | T | 01/14/2022 | PAID (REC#1837436): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: clouds | DALEH | DALEH | | XMS | T | 7240337 |
INNOVATIVE CONSTRUCTION, INC. | XBS | T | 01/14/2022 | PAID (REC#1837436): PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Provided listed wall and ceiling assemblies for hall alcove, revised break room layout. | BPHILLIPS | BPHILLIPS | | XBS | T | 7239953 |
CRONEN PLUMBING AND HEATING, INC. | XPS | T | 01/14/2022 | PAID (REC#1837437): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Delta 4 revisions: Adjusted sheet P100. | SHANEN | SHANEN | | XPS | T | 7239396 |
INNOVATIVE CONSTRUCTION, INC. | XMS | T | 12/17/2021 | PAID (REC#1830495): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: clouds | DALEH | DALEH | | XMS | T | 7212725 |
INNOVATIVE CONSTRUCTION, INC. | XES | T | 12/15/2021 | PAID (REC#1830070): PLAN SPLICE FEE: $50 by: SHELBY for Electrical: Remove CRAC unit. | SHELBY | SHELBY | | XES | T | 7210377 |
INNOVATIVE CONSTRUCTION, INC. | XPS | T | 12/13/2021 | PAID (REC#1829072): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Delta 3 revisions: Adjusted sheet P100. | SHANEN | SHANEN | | XPS | T | 7206250 |
INNOVATIVE CONSTRUCTION, INC. | XBS | T | 12/13/2021 | PAID (REC#1829068): PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Title block and minor labeling revisions. | BPHILLIPS | BPHILLIPS | | XBS | T | 7206237 |