NARVAES WESTERN, LLC | B= | C | 04/05/2023 | All other required Final inspections are complete. (This is a computer generated result) | JASONL | JASONL | | B= | C | 7707360 |
NARVAES WESTERN, LLC | B= | P | 11/17/2022 | Final OK pending the completion of outstanding inspection. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), KENNY ELECTRIC SERVICE, INC. Electrical Final Inspection is not Completed yet, GOLDEN WAY MECHANICAL, INC. Mechanical Final Inspection is not Completed yet, COWBOY PLUMBING LLC Plumbing Final Inspection is not Completed yet. | JASONL | JASONL | | B= | P | 7586962 |
NARVAES WESTERN, LLC | BSP | R | 11/16/2022 | Inspection requested not required | JASONL | JASONL | | BSP | R | 7584783 |
NARVAES WESTERN, LLC | BFR | R | 11/15/2022 | Inspection cancelled by on site supervisor / No inspection performed | JASONL | JASONL | | BFR | R | 7583763 |
NARVAES WESTERN, LLC | BIN | R | 11/10/2022 | inspection cancelled onsite / no inspection performed | BRIANB | BRIANB | | BIN | R | 7579625 |
NARVAES WESTERN, LLC | BFR | P | 11/10/2022 | observed framing at new exterior door openings / pending other rough inspections | BRIANB | BRIANB | | BFR | P | 7579619 |
NARVAES WESTERN, LLC | BFR | P | 11/09/2022 | PARTIAL / INTERIOR LIGHT GAUGE WALL FRAMING / Observed interior light gauge metal wall partition framing / Still need to inspect new exterior door openings, not ready at time of inspection / Pending other rough inspections | JASONL | JASONL | | BFR | P | 7577579 |
NARVAES WESTERN, LLC | BFN | R | 11/08/2022 | Inspection not required | JASONL | JASONL | | BFN | R | 7575727 |
KENNY ELECTRIC SERVICE, INC. | E= | C | 11/18/2022 | Corrections made. | AARONR | AARONR | | E= | C | 7588392 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 11/17/2022 | Need breaker locks for (4x) ice cream machines. --- Air curtain rating MCA 41.9 / MOP 45. | AARONR | AARONR | | E= | P | 7587246 |
KENNY ELECTRIC SERVICE, INC. | ER | C | 11/17/2022 | Ceiling rough OK. | AARONR | AARONR | | ER | C | 7586621 |
KENNY ELECTRIC SERVICE, INC. | E= | R | 11/16/2022 | All receptacles 120v and 240v 50 amps or less need to be GFCI protected. --- Missing 4x receptacles for ice cream machine. --- Missing 2x receptacles for tea machine. --- Need to blank unused j-box with electrical in it. --- Need to see Air Curtain spec sheet. --- Need panel schedules. --- Need to check A/C on roof. | AARONR | AARONR | | E= | R | 7585933 |
KENNY ELECTRIC SERVICE, INC. | E= | R | 11/16/2022 | All receptacles 120v and 240v 50 amps or less need to be GFCI protected. --- Missing 4x receptacles for ice cream machine. --- Missing 2x receptacles for tea machine. --- Need to blank unused j-box with electrical in it. --- Need to see Air Curtain spec sheet. --- Need panel schedules. --- Need to check A/C on roof. | AARONR | AARONR | | E= | R | 7585934 |
KENNY ELECTRIC SERVICE, INC. | ER | R | 11/16/2022 | Need to support lights on opposite corners of light. --- MC touching ceiling grid. --- Low volt touching grid. --- Exit light needs to be fastened to ceiling grid. | AARONR | AARONR | | ER | R | 7585930 |
KENNY ELECTRIC SERVICE, INC. | ER | R | 11/16/2022 | Need to support lights on opposite corners of light. --- MC touching ceiling grid. --- Low volt touching grid. --- Exit light needs to be fastened to ceiling grid. | AARONR | AARONR | | ER | R | 7585931 |
KENNY ELECTRIC SERVICE, INC. | ER | R | 11/14/2022 | Need lights installed in ceiling grid --- Need all j-boxes made up above ceiling --- Need fire alarm installed in ceiling. | AARONR | AARONR | | ER | R | 7582837 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 11/10/2022 | All walls OK.................Scope: Center wall and back wall on west side. | AARONR | AARONR | | ER | P | 7579191 |
KENNY ELECTRIC SERVICE, INC. | ESL | C | 11/08/2022 | Relocated existing PVC in slab from demoed wall to new wall / | ROB | ROB | | ESL | C | 7576935 |
GOLDEN WAY MECHANICAL, INC. | H= | C | 04/03/2023 | SCOPE OF WORK OK / MECHANICAL CONTRACTOR FINAL OK / | LIDO | LIDO | | H= | C | 7705100 |
GOLDEN WAY MECHANICAL, INC. | H= | P | 03/27/2023 | PICTURES RECEIVED OF CONDENSER LABELED AND SECURED TO CURB. SEE IMAGES / FINAL PENDING: ADD CONDENSER (mini split system) TO SCOPE OF WORK / | LIDO | LIDO | | H= | P | 7698278 |
GOLDEN WAY MECHANICAL, INC. | H= | P | 03/13/2023 | ENGINEER STAMPED DOCUMENT APPROVING SAMSUNG MINI SPLIT SYSTEM. SEE IMAGES / FINAL PENDING: ADD MINI SPLIT AND CONDENSER TO SCOPE OF WORK / SECURE CONDENSER TO CURB ON ROOF / LABEL CONDENSER FOR THE AREA SERVED / | LIDO | LIDO | | H= | P | 7685172 |
GOLDEN WAY MECHANICAL, INC. | H= | P | 03/10/2023 | TEST AND BALANCE REPORT RECEIVED. SEE IMAGES / FINAL PENDING: ADD MINI SPLIT AND CONDENSER TO SCOPE OF WORK / SAMSUNG MINI SPLIT SYSTEM INSTALLED, PLANS CALL FOR MITSUBISHI. NEED REVISED EQUIPMENT SCHEDULE SUBMITTED TO PLAN REVIEW OR ENGINEER APPROVED SUBMITTAL / SECURE CONDENSER TO CURB ON ROOF / LABEL CONDENSER FOR THE AREA SERVED / | LIDO | LIDO | | H= | P | 7683738 |
GOLDEN WAY MECHANICAL, INC. | H= | P | 03/09/2023 | IMAGE OF EQUIPMENT SCHEDULE ATTACHED IS NOT ACCEPTED. SEE FOLLOWING NOTES / FINAL PENDING: SAMSUNG MINI SPLIT SYSTEM INSTALLED, PLANS CALL FOR MITSUBISHI. NEED REVISED EQUIPMENT SCHEDULE OR ENGINEER APPROVED SUBMITTAL / SECURE CONDENSER TO CURB ON ROOF / LABEL CONDENSER FOR THE AREA SERVED / NEED TEST AND BALANCE REPORT IS BEING REVIEWED / OK TO ATTACH PICTURES AND DOCUMENTS TO AN INSPECTION REQUEST / | LIDO | LIDO | | H= | P | 7682547 |
GOLDEN WAY MECHANICAL, INC. | H= | P | 03/02/2023 | TEST AND BALANCE REPORT --------UNDER REVIEW | TREVORH | TREVORH | | H= | P | 7674618 |
GOLDEN WAY MECHANICAL, INC. | H= | P | 11/16/2022 | FINAL PENDING: SAMSUNG MINI SPLIT SYSTEM INSTALLED, PLANS CALL FOR MITSUBISHI. NEED REVISED EQUIPMENT SCHEDULE OR ENGINEER APPROVED SUBMITTAL / SECURE CONDENSER TO CURB ON ROOF / LABEL CONDENSER FOR THE AREA SERVED / NEED TEST AND BALANCE REPORT / OK TO ATTACH PICTURES AND DOCUMENTS TO AN INSPECTION REQUEST / | LIDO | LIDO | | H= | P | 7585723 |
GOLDEN WAY MECHANICAL, INC. | HWP | C | 11/16/2022 | CONDENSATE DRAIN COMPLETE / | LIDO | LIDO | | HWP | C | 7585714 |
GOLDEN WAY MECHANICAL, INC. | HRP | C | 11/16/2022 | MINI SPLIT REFRIGERATION LINE-SET CONNECTION TO CASSETTE UNIT AND CONDENSER OK / | LIDO | LIDO | | HRP | C | 7585707 |
GOLDEN WAY MECHANICAL, INC. | HWP | P | 11/14/2022 | MINI SPLIT CONDENSATE DISPOSAL IN WALL ONLY OK / | LIDO | LIDO | | HWP | P | 7582752 |
GOLDEN WAY MECHANICAL, INC. | HRP | R | 11/14/2022 | ADD MINI SPLIT AND CONDENSER TO SCOPE OF WORK / NEED FINAL CONNECTIONS TO CONDENSER ON ROOF AND CASSETTE UNIT / REFRIGERATION LINE SET ROUGH OK / | LIDO | LIDO | | HRP | R | 7582751 |
GOLDEN WAY MECHANICAL, INC. | HD | C | 11/14/2022 | ELECTRIC AIR DOOR (curtain) INSPECTED BY ELECTRICAL INSPECTOR / AC-2 AND AC-3 SUPPLY AND RETURN DUCT ROUGH OK. REGISTERS OK /
| LIDO | LIDO | | HD | C | 7582743 |
COWBOY PLUMBING LLC | P= | C | 11/23/2022 | Correction complete | FRANKM | FRANKM | | P= | C | 7591630 |
COWBOY PLUMBING LLC | P= | P | 11/15/2022 | Field corrections completed via images / change permit work scope to read 2 - sinks & 6 - floor sinks | FRANKM | FRANKM | | P= | P | 7584025 |
COWBOY PLUMBING LLC | P= | P | 11/15/2022 | Trap guards required @ 3 floor drains in middle of prep area (ok to upload images of corrections @ next inspection request) / change permit work scope to 2 - sinks & 6 - floor sinks/drains to record in building history (currently says 6 - washing machines) | FRANKM | FRANKM | | P= | P | 7583487 |
COWBOY PLUMBING LLC | PTO | C | 11/11/2022 | Change permit scope to 2 - sinks & 6 - floor sinks/drns. by final Note : existing VTR | FRANKM | FRANKM | | PTO | C | 7580537 |
COWBOY PLUMBING LLC | PTO | P | 11/10/2022 | OK on in wall DWV & H2O only | FRANKM | FRANKM | | PTO | P | 7579065 |
COWBOY PLUMBING LLC | PB | C | 11/09/2022 | NO DOMESTIC WATER UNDERSLAB | LEE | LEE | | PB | C | 7577365 |